Long-term polyethylene wear rates and clinical outcomes of oxidized zirconium femoral heads on highly cross-linked polyethylene in total hip arthroplasty

被引:0
|
作者
Buckner, Brandt C. [1 ]
Urban, Nathanael D. [1 ]
Cahoy, Kevin M. [1 ]
Lyden, Elizabeth R. [1 ]
Deans, Christopher F. [1 ]
Garvin, Kevin L. [1 ]
机构
[1] Univ Nebraska Med Ctr, Omaha, NE 68198 USA
关键词
ALUMINA CERAMIC HEADS; RANDOMIZED CONTROLLED-TRIAL; CONVENTIONAL POLYETHYLENE; YOUNG-PATIENTS; ACCURACY; FRACTURE; FOLLOW; MULTICENTER; DISLOCATION; INCREASES;
D O I
10.1302/0301-620X.106B3.BJJ-2023-0836
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims Oxidized zirconium (OxZi) and highly cross-linked polyethylene (HXLPE) were developed to minimize wear and risk of osteolysis in total hip arthroplasty (THA). However, retrieval studies have shown that scratched femoral heads may lead to runaway wear, and few reports of long-term results have been published. The purpose of this investigation is to report minimum ten-year wear rates and clinical outcomes of THA with OxZi femoral heads on HXLPE, and to compare them with a retrospective control group of cobalt chrome (CoCr) or ceramic heads on HXLPE. Methods From 2003 to 2006, 108 THAs were performed on 96 patients using an OxZi head with a HXLPE liner with minimum ten-year follow-up. Harris Hip Scores (HHS) were collected preoperatively and at the most recent follow-up (mean 13.3 years). Linear and volumetric liner wear was measured on radiographs of 85 hips with a minimum ten-year follow-up (mean 14.5 years). This was compared to a retrospective control group of 45 THAs using ceramic or CoCr heads from October 1999 to February 2005, with a minimum of ten years' follow-up. Results Average HHS improved from 50.8 to 91.9 and 51.0 to 89.8 in the OxZi group and control group, respectively (p = 0.644), with no osteolysis in either group. Linear and volumetric wear rates in the OxZi group averaged 0.03 mm/year and 3.46 mm(3)/year, respectively. There was no statistically significant difference in HHS scores, nor in linear or volumetric wear rate between the groups, and no revision for any indication. Conclusion The radiological and clinical outcomes, and survivorship of THA with OxZi femoral heads and HXLPE liners, were excellent, and comparable to CoCr or ceramic heads at minimum ten-year follow-up. Wear rates are below what would be expected for development of osteolysis. OxZi-HXLPE is a durable bearing couple with excellent long-term outcomes.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 50 条
  • [1] Highly cross-linked polyethylene improves wear and mid-term failure rates for young total hip arthroplasty patients
    Keeney, James A.
    Martell, John M.
    Pashos, Gail
    Nelson, Christopher J.
    Maloney, William J.
    Clohisy, John C.
    HIP INTERNATIONAL, 2015, 25 (05) : 435 - 441
  • [2] Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty A Randomized Controlled Trial
    McCalden, Richard W.
    MacDonald, Steven J.
    Rorabeck, Cecil H.
    Bourne, Robert B.
    Chess, David G.
    Charron, Kory D.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (04) : 773 - 782
  • [3] Durability of Highly Cross-Linked Polyethylene in Total Hip and Total Knee Arthroplasty
    Dion, Neil T.
    Bragdon, Charles
    Muratoglu, Orhun
    Freiberg, Andrew A.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (03) : 321 - +
  • [4] Short-term outcomes of thin highly cross-linked polyethylene liners in primary total hip arthroplasty
    Bieganowski, Thomas
    Singh, Vivek
    Muthusamy, Nishanth
    Kugelman, David N.
    Davidovitch, Roy, I
    Schwarzkopf, Ran
    HIP INTERNATIONAL, 2023, 33 (05) : 839 - 844
  • [5] The Use of Highly Cross-linked Polyethylene in Total Knee Arthroplasty
    Lachiewicz, Paul F.
    Geyer, Mark R.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (03) : 143 - 151
  • [6] Long-term Wear Data From a Prospective Multicenter Study of Second-Generation Highly Cross-linked Polyethylene Inserts in Total Hip Arthroplasty
    Bonutti, Peter M.
    Mesko, J. Wesley
    Ramakrishnan, Rama
    ORTHOPEDICS, 2018, 41 (04) : E529 - E533
  • [7] Thirteen-year results of cementless total hip arthroplasty with zirconia heads on highly cross-linked polyethylene
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    MODERN RHEUMATOLOGY, 2021, 31 (05) : 1045 - 1049
  • [8] Cross-Linked Versus Conventional Polyethylene for Long-Term Clinical Outcomes After Total Hip Arthroplasty: A Systematic Review and Meta-Analysis
    Shi, Jiangyuan
    Zhu, Weicong
    Liang, Shaohua
    Li, Hongling
    Li, Siming
    JOURNAL OF INVESTIGATIVE SURGERY, 2021, 34 (03) : 307 - 317
  • [9] Unexpected Wear of a Uniquely Designed Moderately Cross-Linked Polyethylene in Total Hip Arthroplasty
    Yakkanti, Ramakanth R.
    Ocksrider, Justin L.
    Patel, Anand A.
    Kolevar, Matthew P.
    Moore, Rebecca D.
    Rimnac, Clare M.
    Kraay, Matthew J.
    Wright, Timothy M.
    Baral, Elexis C.
    Robinson, Raymond P.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (06) : 1130 - 1135
  • [10] Minimum 10-Year Wear Analysis of Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty
    So, Kazutaka
    Goto, Koji
    Kuroda, Yutaka
    Matsuda, Shuichi
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12) : 2224 - 2226