Monte Carlo method for evaluation of surface emission rate measurement uncertainty

被引:0
作者
Li, Yuan-Qiao [1 ]
Lin, Min [1 ,2 ]
Xu, Li-Jun [1 ,2 ]
Luo, Rui [1 ,2 ]
Zhang, Yu-He [1 ,2 ]
Ni, Qian-Xi [3 ,4 ]
Liu, Yun-Tao [1 ,2 ]
机构
[1] China Inst Atom Energy, Beijing 102413, Peoples R China
[2] Natl Key Lab Metrol & Calibrat Tech, Beijing 102413, Peoples R China
[3] Hunan Canc Hosp, Dept Radiat Oncol, Changsha 410031, Peoples R China
[4] Cent South Univ, Affiliated Canc Hosp, Xiangya Sch Med, Changsha 410031, Peoples R China
关键词
Surface emission rate; Monte Carlo method; Metrology; Probability distribution function; Dead time; Low-energy loss correction; Least-squares method; PROPORTIONAL COUNTING SYSTEM; DEAD-TIME; EMITTER; ALPHA;
D O I
10.1007/s41365-024-01474-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The aim of this study is to evaluate the uncertainty of 2 pi alpha and 2 pi beta surface emission rates using the windowless multiwire proportional counter method. This study used the Monte Carlo method (MCM) to validate the conventional Guide to the Expression of Uncertainty in Measurement (GUM) method. A dead time measurement model for the two-source method was established based on the characteristics of a single-channel measurement system, and the voltage threshold correction factor measurement function was indirectly obtained by fitting the threshold correction curve. The uncertainty in the surface emission rate was calculated using the GUM method and the law of propagation of uncertainty. The MCM provided clear definitions for each input quantity and its uncertainty distribution, and the simulation training was realized with a complete and complex mathematical model. The results of the surface emission rate uncertainty evaluation for four radioactive plane sources using both methods showed the uncertainty's consistency E-n<0.070 for the comparison of each source, and the uncertainty results of the GUM were all lower than those of the MCM. However, the MCM has a more objective evaluation process and can serve as a validation tool for GUM results.
引用
收藏
页数:11
相关论文
共 36 条
[1]   Measurement of dead time by time interval distribution method [J].
Arkani, Mohammad ;
Raisali, Gholamreza .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 774 :151-158
[2]   DETERMINATION OF SR-89 AND SR-90 RADIOACTIVE CONCENTRATIONS FROM LEAST-SQUARES FITS TO THE GROWTH DECAY CURVES [J].
BAEZA, A ;
DELRIO, LM ;
MIRO, C ;
PANIAGUA, JM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 312 (1-2) :198-200
[3]   Supplementary comparison of the measurement of the alpha and beta particle surface emission rates from large area sources (CCRI(II)-S10 LASCE) [J].
Felice P.D. ;
Anuradha R. ;
Bludovsky J. ;
Bobin C. ;
Bosley R. ;
Broda R. ;
Capogni M. ;
Collins S.M. ;
Dix T. ;
Frechou C. ;
Hutchins S. ;
Ioan R. ;
Javornik A. ;
Joseph L. ;
Keightley J.D. ;
Kharitonov I.A. ;
King L. ;
Kulkami D.B. ;
Lewis G. ;
Arcos J.M.L. ;
Maringer F.J. ;
Mihelic M. ;
Msimang Z. ;
Nahle O. ;
Netwon S. ;
Pateman D. ;
Sahagia M. ;
Sato Y. ;
Slade J. ;
Sokolova I.A. ;
Sparrow R. ;
Stanev S. ;
Stanga D. ;
Svec A. ;
Szucs L. ;
Thoka W. ;
Unterweger M. ;
Woods M.J. ;
Yamada T. ;
Yamamoto S. ;
Yunoki A. ;
Zanevsky A. ;
Zhao Q. ;
Ziemek T. .
Metrologia, 2022, 59 (1A)
[4]   Application of the iterated weighted least-squares fit to counting experiments [J].
Dembinski, Hans ;
Schmelling, Michael ;
Waldi, Roland .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 940 :135-141
[5]   Dead time corrections using the backward extrapolation method [J].
Gilad, E. ;
Dubi, C. ;
Geslot, B. ;
Blaise, P. ;
Kolin, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 854 :53-60
[6]   New method to incorporate Type B uncertainty into least-squares procedures in radionuclide metrology [J].
Han, Jubong ;
Lee, K. B. ;
Lee, Jong-Man ;
Park, Tae Soon ;
Oh, J. S. ;
Oh, Pil-Jei .
APPLIED RADIATION AND ISOTOPES, 2016, 109 :82-84
[7]  
He H.J., 2016, Nuclear Electron. Detect. Technol., V36, P1172, DOI [10.3969/j.issn.0258-0934.2016.11.021, DOI 10.3969/J.ISSN.0258-0934.2016.11.021]
[8]   Useful and little-known applications of the Least Square Method and some consequences of covariances [J].
Helene, Otaviano ;
Mariano, Leandro ;
Guimaraes-Filho, Zwinglio .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 833 :82-87
[9]  
[黄秋 Huang Qiu], 2012, [核电子学与探测技术, Nuclear Electronics and Detection Technology], V32, P471
[10]  
Hutchinson J., 1995, Metrologia, V32, P326, DOI [10.1088/0026-1394/32/4/15, DOI 10.1088/0026-1394/32/4/15]