Multi-slice spiral CT findings of tubulovillous adenoma of the duodenum

被引:0
|
作者
Li, Li-Chao [1 ]
Zheng, Li-Rong [1 ]
Han, Ning [1 ]
机构
[1] Department of CT, Tangshan Gongren Hospital, Hebei, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Objectives: To analyze the appearance of duodenal tubulovillous adenoma on multi-slice spiral CT images to facilitate early diagnosis and treatment to potentially improve prognosis. Methods: We retrospectively analyzed clinical data and CT imaging findings of 11 cases of duodenal tubulovillous adenomas, all confirmed by pathology. The location, size, shape, CT density, relationship with surrounding structures, accompanying bile duct obstruction, and enhancement pattern of each lesion were documented. Results: All 11 lesions occurred in the descending part of the duodenum. Ten cases occurred in the duodenal papilla area. Nine cases had a low-density ring sign or semicircle sign between the lesion and the adjacent normal intestinal wall on axial images. Eight cases had differing degrees of bile duct dilatation, five of which had concomitant pancreatic duct dilatation. Noncontrast images revealed uniform soft tissue density; contrast enhanced images showed moderate, mostly uniform enhancement, with the most enhancement in the venous phase. In the arterial phase, two lesions showed linear enhancing vessels. Conclusions: On multi-slice spiral CT imaging, duodenal tubulovillous adenomas have certain characteristics that could be used for clinical diagnosis and treatment. Precis: On multi-slice spiral CT imaging of duodenal tubulovillous adenoma, findings of nodular or cauliflower-like shape, uniform density, uniform moderate enhancement, and a peripheral low-density ring sign could improve diagnostic accuracy. © 2021
引用
收藏
页码:135 / 138
相关论文
共 50 条
  • [1] Multi-slice spiral CT findings of tubulovillous adenoma of the duodenum
    Li, Li-Chao
    Zheng, Li-Rong
    Han, Ning
    CLINICAL IMAGING, 2022, 82 : 135 - 138
  • [2] Dose in multi-slice spiral CT
    Spreiter, Q
    Doubrava, C
    von der Haar, T
    Flohr, T
    Schaller, S
    PHYSICA MEDICA, 2000, 16 (03) : 151 - 154
  • [3] Technical advances in multi-slice spiral CT
    Fuchs, T
    Kachelriess, M
    Kalender, WA
    EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) : 69 - 73
  • [4] The effect of pitch in multi-slice spiral/helical CT
    Wang, G
    Vannier, MW
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 116 - 127
  • [5] Characterization of motion artifacts in multi-slice spiral CT
    Graf, H
    Heuschmid, M
    Küttner, A
    Kopp, AF
    Claussen, CD
    Schick, F
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (10): : 1301 - 1308
  • [6] TUBULOVILLOUS ADENOMA OF THE DUODENUM
    ALLES, JU
    KRACHT, J
    STAMBOLIS, C
    MEDIZINISCHE WELT, 1985, 36 (39): : 1252 - 1256
  • [7] Diagnosis value of multi-slice spiral CT in renal trauma
    Peng, Naixiong
    Wang, Xisheng
    Zhang, Zejian
    Fu, Shui
    Fan, Jiqing
    Zhang, Yuanyuan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (05) : 649 - 655
  • [8] Dynamic reconstruction of the lung using multi-slice spiral CT
    Wang, G
    Hoffman, EA
    Heuscher, DJ
    Chandra, S
    RADIOLOGY, 2000, 217 : 565 - 565
  • [9] Diagnostic value of multi-slice spiral CT in aortic dissection
    刘昌伟
    黄向明
    符水
    South China Journal of Cardiology, 2010, 11 (04) : 234 - 237
  • [10] Temporal resolution of multi-slice spiral CT with subsecond scanning
    Liang, Y
    Kopecky, KK
    Ruimi, D
    RADIOLOGY, 1998, 209P : 284 - 285