Performance analysis of high voltage disc insulators with different profiles in clean and polluted environments using flashover, withstand voltage tests and finite element analysis

被引:0
|
作者
Ali, Arfan [1 ,2 ]
Bhatti, Abdul Rauf [1 ]
Rasool, Akhtar [3 ]
Rehman, Fazal Ur [2 ]
Khan, Muhammad Amjad [2 ]
Ali, Ahmed [4 ]
Sherefa, Abdulkerim [5 ]
机构
[1] Govt Coll Univ Faisalabad, Dept Elect Engn & Technol, Faisalabad 38000, Pakistan
[2] Natl Transmiss & Despatch Co, Lahore 54000, Pakistan
[3] Univ Botswana, Dept Elect Engn, UB0061, Gaborone, Botswana
[4] Univ Johannesburg, Fac Engn & Built Environm, Dept Elect & Elect Engn Technol, ZA-2092 Johannesburg, South Africa
[5] Wolkite Univ, Dept Elect & Comp Engn, Wolkite, Ethiopia
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
D O I
10.1038/s41598-024-71392-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Severe pollution-induced flashovers on insulators present a pressing challenge to power system safety. The frequent failure of high-voltage insulators, particularly in the polluted environments of Pakistan, poses a critical concern. This paper investigates the impact of insulator profile on reducing pollution flashovers, testing two designs as per IEC standard 60383 and simulated using the Finite Element Method in COMSOL Multiphysics (R). The test results revealed that deep under-ribs insulators exhibited a 5.008% reduction in flashover voltage, while alternating shed insulators experienced a 3.233% decrease in polluted conditions compared to clean conditions. Notably, under both clean and polluted conditions, alternating shed insulators consistently outperformed deep under-ribs insulators, with a 25.377% higher flashover voltage in clean conditions and a 27.400% superiority in polluted conditions. Computational analysis through the Finite Element Method in COMSOL Multiphysics shows a consistent pattern in potential distribution with increasing insulator count, but the presence of a pollution layer introduces spikes in the electric field distribution, validating experimental results. These findings highlight the superior performance of alternating shed insulators, especially in polluted environments.
引用
收藏
页数:26
相关论文
共 50 条
  • [21] Finite element analysis of novel dual-redundancy high voltage BLDCM
    Fu, Zhaoyang
    Liu, Jinglin
    Zhao, Xiaopeng
    Xibei Gongye Daxue Xuebao/Journal of Northwestern Polytechnical University, 2010, 28 (01): : 37 - 41
  • [22] Voltage Elevation Analysis of Overhead Distribution Lines Using the Finite Element Method
    de Oliveira, P. S.
    Biasotto, E.
    Lima, M. A. A.
    Vieira, J. C. M.
    Oleskovicz, M.
    Coury, D. V.
    Suzuki, M.
    Miranda, S. A. N.
    Querne, H. F. R.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [23] Dynamic braking of a voltage supplied induction motor using finite element analysis
    Pham, TH
    Wendling, PF
    Lombard, P
    Salon, SJ
    Acikgoz, H
    1997 IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE RECORD, 1997, : WB331 - WB333
  • [24] Modelling of partial discharge pulses in high voltage cable insulation using finite element analysis software
    Illias, H. A.
    Yon, H. R.
    Bakar, A. H. A.
    Mokhlis, H.
    Chen, G.
    Lewin, P. L.
    Ariffin, A. M.
    2013 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2013, : 52 - 56
  • [25] Electric Field Analysis of Extra High Voltage (EHV) Underground Cables Using Finite Element Method
    Kumar, Mantosh
    Bhaskar, Mahajan Sagar
    Padmanaban, Sanjeevikumar
    Siano, Pierluigi
    Blaabjerg, Frede
    Leonowicz, Zbigniew
    2017 1ST IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2017 17TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2017,
  • [26] Finite element model of high-voltage transmission tower environmental sensitivity analysis
    School of Civil Engineering and Architecture, Northeast Dianli University, Jilin
    132012, China
    不详
    110015, China
    Yingyong Jichu yu Gongcheng Kexue Xuebao, 4 (805-814):
  • [27] Electromagnetic and Thermal Analysis of High Voltage Three-Phase Underground Cables Using Finite Element Method
    Conti, Stefania
    Dilettoso, Emanuele
    Rizzo, Santi Agatino
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [28] Finite Element Analysis of a High Voltage Semiconductor Polymeric Package Design using a Taguchi Based Experimental Design
    Nobeen, N. S.
    Whalley, D. C.
    Hutt, D. A.
    Haworth, B.
    2012 4TH ELECTRONIC SYSTEM-INTEGRATION TECHNOLOGY CONFERENCE (ESTC), 2012,
  • [29] Flashover process analysis of non-uniformly polluted insulation surface using experimental design methodology and finite element method
    Terrab, Hocine
    Boulanouar, Hasna
    Bayadi, Abdelhafid
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 163 : 581 - 589
  • [30] High Frequency Finite Element Analysis of Electromagnetic Radiation due to Partial Discharges in High Voltage Equipment
    Xiao, S.
    Moore, P. J.
    Judd, M. D.
    Portugues, I. E.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 3822 - +