In recent years, with increasing complex grid environment and growing wind power penetration, the operation technique of doubly fed induction generator (DFIG) under nonideal grid conditions, including harmonic distortion, voltage unbalance, and voltage dip, has been a research hotspot. Under harmonic distorted and unbalanced grid conditions, some enhanced control strategies can be used to improve the performance of the DFIG itself or to benefit the power quality at the point of common coupling. When the grid voltage dips, protecting measures based on software or hardware are required to keep the DFIG connected to the grid and support the voltage restoration by providing reactive power. In this paper, the existing researches in the aforementioned fields are reviewed. Different technical solutions for DFIG operating under non-ideal grid conditions are compared, then the technical trends and potential research topics are discussed and prospected. © 2020, Electrical Technology Press Co. Ltd. All right reserved.
引用
收藏
页码:455 / 471
页数:16
相关论文
共 121 条
  • [1] Hu S., Meng Y., Gong W., Et al., Operation control strategy of DFIG wind turbine under non-ideal grid conditions, Transactions of China Electrotechnical Society, 28, 5, pp. 99-104, (2013)
  • [2] Xu L., Wang Y., Dynamic modeling and control of dfig-based wind turbines under unbalanced network conditions, IEEE Transactions on Power Systems, 22, 1, pp. 314-323, (2007)
  • [3] Xu L., Enhanced control and operation of DFIG-based wind farms during network unbalance, IEEE Transactions on Energy Conversion, 23, 4, pp. 1073-1081, (2008)
  • [4] Hu J., Nian H., Xu H., Et al., Dynamic modeling and improved control of DFIG under distorted grid voltage conditions, IEEE Transactions on Energy Conversion, 26, 1, pp. 163-175, (2011)
  • [5] Xu H., Hu J., He Y., Integrated modeling and enhanced control of DFIG under unbalanced and distorted grid voltage conditions, IEEE Transactions on Energy Conversion, 27, 3, pp. 725-736, (2012)
  • [6] Shang L., Hu J., Sliding-mode-based direct power control of grid-connected wind-turbine-driven doubly fed induction generators under unbalanced grid voltage conditions, IEEE Transactions on Energy Conversion, 27, 2, pp. 362-373, (2012)
  • [7] Zarei M.E., Nicolas C.V., Arribas J.R., Improved Predictive direct power control of doubly fed induction generator during unbalanced grid voltage based on four vectors, IEEE Journal of Emerging and Selected Topics in Power Electronics, 5, 2, pp. 695-707, (2017)
  • [8] Santos-Martin D., Rodriguez-Amenedo J.L., Arnalte S., Direct power control applied to doubly fed induction generator under unbalanced grid voltage conditions, IEEE Transactions on Power Electronics, 23, 5, pp. 2328-2336, (2008)
  • [9] Santos-Martin D., Rodriguez-Amenedo J.L., Arnalte S., Providing ride-through capability to a doubly fed induction generator under unbalanced voltage dips, IEEE Transactions on Power Electronics, 24, 7, pp. 1747-1757, (2009)
  • [10] Xiong P., Sun D., Backstepping-based DPC strategy of a wind turbine-driven DFIG under normal and harmonic grid voltage, IEEE Transactions on Power Electronics, 31, 6, pp. 4216-4225, (2016)