On the feasibility of ultrasound Doppler-based personalized hemodynamic modeling of the abdominal aorta

被引:0
作者
Fonken, Judith [1 ,2 ]
Gillissen, Milan [1 ,2 ]
van Engelen, Eline [1 ]
van Sambeek, Marc [1 ,2 ]
van de Vosse, Frans [3 ]
Lopata, Richard [1 ]
机构
[1] Eindhoven Univ Technol, Photoacoust & Ultrasound Lab Eindhoven PULS e, Groene Loper 3, NL-5612 AE Eindhoven, Netherlands
[2] Catharina Hosp, Dept Vasc Surg, Michelangelolaan 2, NL-5623 EJ Eindhoven, Netherlands
[3] Eindhoven Univ Technol, Cardiovasc Biomech, Groene Loper 3, NL-5612 AE Eindhoven, Netherlands
关键词
Abdominal aortic aneurysms; Ultrasound Doppler; Hemodynamics; Personalized modeling; Computational fluid dynamics; FLUID-STRUCTURE INTERACTION; WALL STRESS-ANALYSIS; COLOR DOPPLER; BLOOD-FLOW; ANEURYSMS; BIOMECHANICS; LIMITATIONS; RUPTURE; RISK; REST;
D O I
10.1186/s12938-024-01267-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BackgroundPersonalized modeling is a promising tool to improve abdominal aortic aneurysm (AAA) rupture risk assessment. Computed tomography (CT) and quantitative flow (Q-flow) magnetic resonance imaging (MRI) are widely regarded as the gold standard for acquiring patient-specific geometry and velocity profiles, respectively. However, their frequent utilization is hindered by various drawbacks. Ultrasound is used extensively in current clinical practice and offers a safe, rapid and cost-effective method to acquire patient-specific geometries and velocity profiles. This study aims to extract and validate patient-specific velocity profiles from Doppler ultrasound and to examine the impact of the velocity profiles on computed hemodynamics.MethodsPulsed-wave Doppler (PWD) and color Doppler (CD) data were successfully obtained for six volunteers and seven patients and employed to extract the flow pulse and velocity profile over the cross-section, respectively. The US flow pulses and velocity profiles as well as generic Womersley profiles were compared to the MRI velocities and flows. Additionally, CFD simulations were performed to examine the combined impact of the velocity profile and flow pulse.ResultsLarge discrepancies were found between the US and MRI velocity profiles over the cross-sections, with differences for US in the same range as for the Womersley profile. Differences in flow pulses revealed that US generally performs best in terms of maximum flow, forward flow and ratios between forward and backward flow, whereas it often overestimates the backward flow. Both spatial patterns and magnitude of the computed hemodynamics were considerably affected by the prescribed velocity boundary conditions. Larger errors and smaller differences between the US and generic CFD cases were observed for patients compared to volunteers.ConclusionThese results show that it is feasible to acquire the patient-specific flow pulse from PWD data, provided that the PWD acquisition could be performed proximal to the aneurysm region, and resulted in a triphasic flow pattern. However, obtaining the patient-specific velocity profile over the cross-section using CD data is not reliable. For the volunteers, utilizing the US flow profile instead of the generic flow profile generally resulted in improved performance, whereas this was the case in more than half of the cases for the patients.
引用
收藏
页数:17
相关论文
共 50 条
[31]  
Sakuma H, 2001, MAGNET RESON MED, V45, P346, DOI 10.1002/1522-2594(200102)45:2<346::AID-MRM1044>3.0.CO
[32]  
2-I
[33]   Biomechanical Investigation of Disturbed Hemodynamics-Induced Tissue Degeneration in Abdominal Aortic Aneurysms Using Computational and Experimental Techniques [J].
Salman, Huseyin Enes ;
Ramazanli, Burcu ;
Yavuz, Mehmet Metin ;
Yalcin, Huseyin Cagatay .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2019, 7
[34]   Wall stress and flow dynamics in abdominal aortic aneurysms: finite element analysis vs. fluid-structure interaction [J].
Scotti, Christine M. ;
Jimenez, Jorge ;
Muluk, Satish C. ;
Finol, Ender A. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 (03) :301-322
[35]   Compliant biomechanics of abdominal aortic aneurysms: A fluid-structure interaction study [J].
Scotti, Christine M. ;
Finol, Ender A. .
COMPUTERS & STRUCTURES, 2007, 85 (11-14) :1097-1113
[36]   Fluid-structure interaction in abdominal aortic aneurysms: effects of asymmetry and wall thickness [J].
Scotti, Christine M. ;
Shkolnik, Alexander D. ;
Muluk, Satish C. ;
Finol, Ender A. .
BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
[37]  
Sequeira A., 2007, PORTRAIT STATE OF TH, P65, DOI DOI 10.1007/978-1-4020-5690-1_4
[38]   SPATIOTEMPORAL REGISTRATION OF 3-D MULTI-PERSPECTIVE ULTRASOUND IMAGES OF ABDOMINAL AORTIC ANEURYSMS [J].
Sjoerdsma, Marloes ;
Verstraeten, Sabine C. F. P. M. ;
Maas, Esther J. ;
Van De Vosse, Frans N. ;
Van Sambeek, Marc R. H. M. ;
Lopata, Richard G. P. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (01) :318-332
[39]   Extraction of Peak Velocity Profiles from Doppler Echocardiography Using Image Processing [J].
Taebi, Amirtaha ;
Sandler, Richard H. ;
Kakavand, Bahram ;
Mansy, Hansen A. .
BIOENGINEERING-BASEL, 2019, 6 (03)
[40]   The Effect of Blood Rheology and Inlet Boundary Conditions on Realistic Abdominal Aortic Aneurysms under Pulsatile Flow Conditions [J].
Tzirakis, Konstantinos ;
Kamarianakis, Yiannis ;
Kontopodis, Nikolaos ;
Ioannou, Christos V. V. .
BIOENGINEERING-BASEL, 2023, 10 (02)