On the feasibility of ultrasound Doppler-based personalized hemodynamic modeling of the abdominal aorta

被引:0
作者
Fonken, Judith [1 ,2 ]
Gillissen, Milan [1 ,2 ]
van Engelen, Eline [1 ]
van Sambeek, Marc [1 ,2 ]
van de Vosse, Frans [3 ]
Lopata, Richard [1 ]
机构
[1] Eindhoven Univ Technol, Photoacoust & Ultrasound Lab Eindhoven PULS e, Groene Loper 3, NL-5612 AE Eindhoven, Netherlands
[2] Catharina Hosp, Dept Vasc Surg, Michelangelolaan 2, NL-5623 EJ Eindhoven, Netherlands
[3] Eindhoven Univ Technol, Cardiovasc Biomech, Groene Loper 3, NL-5612 AE Eindhoven, Netherlands
关键词
Abdominal aortic aneurysms; Ultrasound Doppler; Hemodynamics; Personalized modeling; Computational fluid dynamics; FLUID-STRUCTURE INTERACTION; WALL STRESS-ANALYSIS; COLOR DOPPLER; BLOOD-FLOW; ANEURYSMS; BIOMECHANICS; LIMITATIONS; RUPTURE; RISK; REST;
D O I
10.1186/s12938-024-01267-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BackgroundPersonalized modeling is a promising tool to improve abdominal aortic aneurysm (AAA) rupture risk assessment. Computed tomography (CT) and quantitative flow (Q-flow) magnetic resonance imaging (MRI) are widely regarded as the gold standard for acquiring patient-specific geometry and velocity profiles, respectively. However, their frequent utilization is hindered by various drawbacks. Ultrasound is used extensively in current clinical practice and offers a safe, rapid and cost-effective method to acquire patient-specific geometries and velocity profiles. This study aims to extract and validate patient-specific velocity profiles from Doppler ultrasound and to examine the impact of the velocity profiles on computed hemodynamics.MethodsPulsed-wave Doppler (PWD) and color Doppler (CD) data were successfully obtained for six volunteers and seven patients and employed to extract the flow pulse and velocity profile over the cross-section, respectively. The US flow pulses and velocity profiles as well as generic Womersley profiles were compared to the MRI velocities and flows. Additionally, CFD simulations were performed to examine the combined impact of the velocity profile and flow pulse.ResultsLarge discrepancies were found between the US and MRI velocity profiles over the cross-sections, with differences for US in the same range as for the Womersley profile. Differences in flow pulses revealed that US generally performs best in terms of maximum flow, forward flow and ratios between forward and backward flow, whereas it often overestimates the backward flow. Both spatial patterns and magnitude of the computed hemodynamics were considerably affected by the prescribed velocity boundary conditions. Larger errors and smaller differences between the US and generic CFD cases were observed for patients compared to volunteers.ConclusionThese results show that it is feasible to acquire the patient-specific flow pulse from PWD data, provided that the PWD acquisition could be performed proximal to the aneurysm region, and resulted in a triphasic flow pattern. However, obtaining the patient-specific velocity profile over the cross-section using CD data is not reliable. For the volunteers, utilizing the US flow profile instead of the generic flow profile generally resulted in improved performance, whereas this was the case in more than half of the cases for the patients.
引用
收藏
页数:17
相关论文
共 50 条
[1]   Towards the 2D velocity reconstruction in abdominal aorta from Color-Doppler Ultrasound [J].
Antonuccio, Maria Nicole ;
Morales, Hernan G. ;
This, Alexandre ;
Capellini, Katia ;
Avril, Stephane ;
Celi, Simona ;
Rouet, Laurence .
MEDICAL ENGINEERING & PHYSICS, 2022, 107
[2]   Emerging Technology: Ultrasound Vector Flow Imaging-A Novel Approach to Arterial Hemodynamic Quantification [J].
Baun, Jim .
JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2021, 37 (06) :599-606
[3]   A wave propagation model of blood flow in large vessels using an approximate velocity profile function [J].
Bessems, David ;
Rutten, Marcel ;
Van De Vosse, Frans .
JOURNAL OF FLUID MECHANICS, 2007, 580 :145-168
[4]   Hemodynamics of the Normal Aorta Compared to Fusiform and Saccular Abdominal Aortic Aneurysms with Emphasis on a Potential Thrombus Formation Mechanism [J].
Biasetti, Jacopo ;
Gasser, T. Christian ;
Auer, Martin ;
Hedin, Ulf ;
Labruto, Fausto .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (02) :380-390
[5]   Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics [J].
Bollache, Emilie ;
van Ooij, Pim ;
Powell, Alex ;
Carr, James ;
Markl, Michael ;
Barker, Alex J. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (10) :1529-1541
[6]   Low wall shear stress predominates at sites of abdominal aortic aneurysm rupture [J].
Boyd, April J. ;
Kuhn, David C. S. ;
Lozowy, Richard J. ;
Kulbisky, Gordon P. .
JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) :1613-1619
[7]   The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm [J].
Chaikof, Elliot L. ;
Dalman, Ronald L. ;
Eskandari, Mark K. ;
Jackson, Benjamin M. ;
Lee, W. Anthony ;
Mansour, M. Ashraf ;
Mastracci, Tara M. ;
Mell, Matthew ;
Murad, M. Hassan ;
Nguyen, Louis L. ;
Oderich, Gustavo S. ;
Patel, Madhukar S. ;
Schermerhorn, Marc L. ;
Starnes, Benjamin W. .
JOURNAL OF VASCULAR SURGERY, 2018, 67 (01) :2-+
[8]   Fluid-Structure Interaction Modeling of Abdominal Aortic Aneurysms: The Impact of Patient-Specific Inflow Conditions and Fluid/Solid Coupling [J].
Chandra, Santanu ;
Raut, Samarth S. ;
Jana, Anirban ;
Biederman, Robert W. ;
Doyle, Mark ;
Muluk, Satish C. ;
Finol, Ender A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (08)
[9]   Comparison of abdominal aortic hemodynamics between men and women at rest and during lower limb exercise [J].
Cheng, CP ;
Herfkens, RJ ;
Taylor, CA .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (01) :118-123
[10]  
Collin J, 1999, LANCET, V353, P407, DOI 10.1016/S0140-6736(05)74979-5