Totally implantable venous ports in infants and children: a single-center retrospective study of indications and safety

被引:2
作者
Sosnowska-Sienkiewicz, Patrycja [1 ]
Morycinski, Sebastian [1 ]
Januszkiewicz-Lewandowska, Danuta [2 ]
Michalik, Karolina [1 ]
Madziar, Klaudyna [3 ]
Kukfisz, Agata [4 ]
Zielinska, Daria [5 ]
Mankowski, Przemyslaw [1 ]
机构
[1] Poznan Univ Med Sci, Dept Pediat Surg Traumatol & Urol, Poznan, Poland
[2] Poznan Univ Med Sci, Dept Pediat Oncol Hematol & Transplantol, Poznan, Poland
[3] Poznan Univ Med Sci, Dept Perinatol & Gynecol, Poznan, Poland
[4] Med Univ Silesia, Fac Med Sci Zabrze, Zabrze, Poland
[5] Prov Hosp Neurol & Mental Illness, Lubiaz, Poland
关键词
long-term access; child; Seldinger method; venous port; complications; infections; ACCESS DEVICES; COMPLICATIONS; CATHETERS; ONCOLOGY; CARE; EXPERIENCE;
D O I
10.3389/fonc.2024.1351630
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction Totally Implantable Venous Access Devices (TIVADs) contribute significantly to the treatment progress and comfort of patients requiring long-term therapy. However, the procedure for implanting TIVADs, as well as its very presence, may be associated with complications.Aim This study evaluates the indications, safety, and complication rates of venous port implantations in pediatric patients. It also explores factors influencing the occurrence of early and late complications post-implantation.Materials and methods The study included 383 pediatric patients treated at the Department of Pediatric Surgery, Traumatology, and Urology in Poznan between 2013 and 2020 who underwent 474 implantations of intravenous ports. Venous access was achieved using the Seldinger technique. Statistical analysis was performed using Statistica 13 with TIBCO and PQStat 1.8.2.156 with PQStat.Results Venous ports were used in 345 oncology patients requiring chemotherapy (90% of the total group) and in 38 children (10%) with non-oncology indications. There were 36 early complications (7.6%) and 18 late complications (3.8%), excluding infectious complications. The most common early, non-infectious complications included pneumothorax (15 patients; 3%) and port pocket hematoma (12 patients; 2.5%). The most common late, non-infectious complications observed were venous catheter obstruction (8 children; 1.7%) and port system leakage (5 children; 1%). Infectious complications occurred in 129 cases (27.2%). Children with a diagnosis of non-Hodgkin's lymphoma, acute myeloid leukemia, and acute lymphoblastic leukemia had a significantly higher incidence of port infections. Venous ports equipped with a polyurethane catheter, compared to systems with a silicone catheter, functioned significantly shorter.Conclusions The Seldinger method of port implantation is quick, minimally invasive, and safe. The type of port, including the material of the port's venous catheter, and the underlying disease have an impact on the durability of implantable intravenous systems. The experience of the surgeon is related to the frequency of complications associated with the procedure.
引用
收藏
页数:11
相关论文
共 44 条
[1]   Implanted vascular access devices (ports) in children: complications and their prevention [J].
Babu, R ;
Spicer, RD .
PEDIATRIC SURGERY INTERNATIONAL, 2002, 18 (01) :50-53
[2]  
Bagnall-Reeb Holly, 2004, J Infus Nurs, V27, P118, DOI 10.1097/00129804-200403000-00008
[3]   Totally Implantable Central Venous Access Ports. Analysis of 700 Cases [J].
Barbetakis, Nikolaos ;
Asteriou, Christos ;
Kleontas, Athanassios ;
Tsilikas, Christodoulos .
JOURNAL OF SURGICAL ONCOLOGY, 2011, 104 (06) :654-656
[4]   Totally implantable venous access port insertion via open Seldinger approach of the internal jugular vein-a retrospective risk stratification of 500 consecutive patients [J].
Becker, Felix ;
Wurche, Lennart A. ;
Darscht, Martina ;
Pascher, Andreas ;
Struecker, Benjamin .
LANGENBECKS ARCHIVES OF SURGERY, 2021, 406 (03) :903-910
[5]   Totally implantable venous access ports systems for patients receiving chemotherapy for solid tissue malignancies: A randomized controlled clinical trial examining the safety, efficacy, costs, and impact on quality of life [J].
Bow, EJ ;
Kilpatrick, MG ;
Clinch, JJ .
JOURNAL OF CLINICAL ONCOLOGY, 1999, 17 (04) :1267-1273
[6]   Incidence and risk factor for infection of totally implantable venous access port [J].
Chang, Tung-Cheng ;
Yen, Min-Hsuan ;
Kiu, Kee-Thai .
LANGENBECKS ARCHIVES OF SURGERY, 2022, 407 (01) :343-351
[7]  
Cil Barbaros Erhan, 2006, Diagn Interv Radiol, V12, P93
[8]  
Cohen Lindsey L, 2008, Pediatrics, V122 Suppl 3, pS134, DOI 10.1542/peds.2008-1055f
[9]  
Dheer Geetika, 2011, J Indian Assoc Pediatr Surg, V16, P145, DOI 10.4103/0971-9261.86873
[10]  
Dogar SA, 2013, J PAK MED ASSOC, V63, P1248