Prior studies on cryogenic thermal contact resistance (TCR) measurement mainly focus on liquid nitrogen temperature region and above. There are limited solid TCR data in the lower temperature region. The present measurement is based on an RDK-408D2 two-stage G-M cryogenic refrigerator. By using the laminated method, the TCR data of brass samples in the temperature range of 10—30 K at different roughnesses and preloads are measured and the influence of different factors on TCR is discussed. The results show that the TCR of the brass contact surface in this temperature zone is between 6.89×10-4 and 1.86×10-2 m2·W/K. With a smaller roughness of the contact surface, higher temperature, and greater pre-tightening force, the TCR becomes smaller. This behavior is consistent with the conventional qualitative understanding. The above cryogenic experimental data can provide certain support for the calculation of TCR for related cryogenic application design. © 2023 Shanghai Jiao Tong University. All rights reserved.
引用
收藏
页码:76 / 83
页数:7
相关论文
共 21 条
  • [1] FUJII Y, MORITANI A, NAKAI J., Photoacoustic spectroscopy theory for multi-layered samples and interference effect, Japanese Journal of Applied Physics, 20, 2, (1981)
  • [2] BAUMANN J, TILGNER R., Determining photothermally the thickness of a buried layer, Journal of Applied Physics, 58, 5, pp. 1982-1985, (1985)
  • [3] SALAZAR A, SANCHEZ-LAVEGA A., Thermal diffusivity measurements using linear relations from photothermal wave experiments, Review of Scientific Instruments, 65, 9, pp. 2896-2900, (1994)
  • [4] KWON O, SHI L, MAJUMDAR A., Scanning thermal wave microscopy (STWM), Journal of Heat Transfer, 125, pp. 156-163, (2003)
  • [5] LARSON K B, KOYAMA K., Measurement by the flash method of thermal diffusivity, heart capacity, and thermal conductivity in two-layer composite samples, Journal of Applied Physics, 39, 9, pp. 4408-4416, (1968)
  • [6] LE NILIOT C, GALLET P., Infrared thermography applied to the resolution of inverse heat conduction problems: Recovery of heat line sources and boundary conditions, Revue Générale De Thermique, 37, 8, pp. 629-643, (1998)
  • [7] ZHOU Jiemin, ZHU Zaixing, XIE Dongjiang, Et al., Thermal physical property of refractory material measured by plane heat source method with constant heat rate, Journal of Central South University (Science and Technology), 42, 5, pp. 1467-1472, (2011)
  • [8] CAHILL D G., Thermal conductivity measurement from 30 to 750 K: The 3ω method, Review of Scientific Instruments, 61, 2, pp. 802-808, (1990)
  • [9] YOUNG D A, THOMSEN C, GRAHN H T, Et al., Heat flow in glasses on a picosecond timescale, Phonon Scattering in Condensed Matter V, pp. 49-51, (1986)
  • [10] CHEN M J, LI Q, ZHANG P., Experimental investigation of high temperature thermal contact resistance of thin disk samples using infrared camera in vacuum condition, International Journal of Heat and Mass Transfer, 157, (2020)