Design and implementation of control system for fault current limiter

被引:0
|
作者
Liu Y. [1 ]
Zhou Q. [1 ]
Fang T. [1 ,2 ]
Wang D. [1 ]
Ding F. [1 ]
Lü W. [1 ]
机构
[1] NR Electric Co. Ltd, Nanjing
[2] NARI Group Corporation (State Grid Electric Power Research Institute), Nanjing
来源
Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control | 2020年 / 48卷 / 01期
关键词
Control system; Embedded platform; Fault current limiter; Fault identification; High real-time;
D O I
10.19783/j.cnki.pspc.190177
中图分类号
学科分类号
摘要
Aiming at the high-speed and high-real-time application requirements of fault current limiter, the control system based on embedded platform is designed and implemented in this paper. In modular design, the hardware includes three parts: data acquisition unit, main control unit and sub-module control unit. High-performance DSP and FPGA are adopted in the core control module. The control software consists of fault identification module, state monitoring module and logic control module. The fault identification module adopts amplitude calculation method based on short data window and the control logic and its related settings are also designed in detail. Through type test and RTDS test, the system can quickly identify short-circuit fault and control the fault current limiter, which lays a foundation for the engineering application of fault current limiter. © 2020, Power System Protection and Control Press. All right reserved.
引用
收藏
页码:150 / 156
页数:6
相关论文
共 24 条
  • [1] Schmitt H., Amon-Filho J., Adapa R., Application and feasibility of fault current limiters in power systems, CIGRE Technical Brochure, 2, (2012)
  • [2] Zheng J., Current status and application prospect of fault current limiters, Proceedings of the CSEE, 34, 29, pp. 5140-5148, (2014)
  • [3] Patil S., Thorat A., Development of fault current limiters: a review, 2017 International Conference on Data Management, Analytics and Innovation (ICDMAI), pp. 122-126, (2017)
  • [4] Liu K., Chen H., Lin J., Et al., Study situation of applications of fault current limiter in power system, Power System Protection and Control, 38, 7, pp. 147-151, (2010)
  • [5] Wei Y., Han S., Xu K., Critical review on high-voltage series resonance type fault current limiter, High Voltage Apparatus, 49, 7, pp. 104-109, (2013)
  • [6] Chen G., Jiang D., Lu Z., Et al., A novel topology of solid state fault current limiter and its control strategy, Automation of Electric Power Systems, 28, 3, pp. 32-36, (2004)
  • [7] Ghanbari T., Farjah E., Development of an efficient solid-state fault current limiter for microgrid, IEEE Transactions on Power Delivery, 27, 4, pp. 1829-1834, (2012)
  • [8] Chen S., Li P., Ball R., Et al., Analysis of a switched impedance transformer-type nonsuperconducting fault current limiter, IEEE Transactions on Power Electronics, 30, 4, pp. 1925-1936, (2014)
  • [9] Gong J., Zhu J., Fang J., Et al., Analysis of transient resistance characteristics for resistive type high temperature superconducting fault current limiter, Transactions of China Electrotechnical Society, 33, 9, pp. 204-212, (2018)
  • [10] Qie Z., Zhu B., Liu F., Et al., Defense measures of magnetic-controlled fault current limiter for power grid access, Smart Power, 47, 6, pp. 95-100, (2019)