Effect of Poly(ethylene glycol) Configuration on Microbubble Pharmacokinetics

被引:3
|
作者
Navarro-Becerra, J. Angel [1 ,2 ]
Castillo, Jair I. [2 ]
Borden, Mark A. [1 ,2 ]
机构
[1] Univ Colorado Boulder, Mech Engn Dept, Boulder, CO 80309 USA
[2] Univ Colorado Boulder, Biomed Engn Program, Boulder, CO 80309 USA
基金
美国国家卫生研究院;
关键词
poly(ethylene glycol) configuration; microbubble volumedose; pharmacokinetics; immune response; BLOOD-BRAIN-BARRIER; ULTRASOUND CONTRAST AGENT; FOCUSED ULTRASOUND; VISCOELASTIC PROPERTIES; COATED MICROBUBBLES; PHASE-BEHAVIOR; DRUG-DELIVERY; IN-VITRO; SIZE; PEG;
D O I
10.1021/acsbiomaterials.3c01764
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Microbubbles (MBs) hold substantial promise for medical imaging and therapy; nonetheless, knowledge gaps persist between composition, structure, and in vivo performance, especially with respect to pharmacokinetics. Of particular interest is the role of the poly(ethylene glycol) (PEG) layer, which is thought to shield the MB against opsonization and rapid clearance but is also known to cause an antibody response upon multiple injections. The goal of this study was, therefore, to elucidate the role of the PEG layer in circulation persistence of MBs in the naive animal (prior to an adaptive immune response). Here, we directly observe the number and size of individual MBs obtained from blood samples, unifying size and concentration into the microbubble volume dose (MVD) parameter. This approach enables direct evaluation of the pharmacokinetics of intact MBs, comprising both the lipid shell and gaseous core, rather than separately assessing the lipid or gas components. We examined the in vivo circulation persistence of 3 mu m diameter phospholipid-coated MBs with three different mPEG(2000) content: 2 mol % (mushroom), 5 mol % (intermediate), and 10 mol % (brush). MB size and concentration in the blood were evaluated by a hemocytometer analysis over 30 min following intravenous injections of 20 and 40 mu L/kg MVD in Sprague-Dawley rats. Interestingly, pharmacokinetic analysis demonstrated that increasing PEG concentration on the MB surface resulted in faster clearance. This was evidenced by a 1.6-fold reduction in half-life and area under the curve (AUC) (p < 0.05) in the central compartment. Conversely, the AUC in the peripheral compartment increased with PEG density, suggesting enhanced MB trapping by the mononuclear phagocyte system. This was supported by an in vitro assay, which showed a significant rise in complement C3a activation with a higher PEG content. In conclusion, a minimal PEG concentration on the MB shell (mushroom configuration) was found to prolong circulation and mitigate immunogenicity.
引用
收藏
页码:3331 / 3342
页数:12
相关论文
共 50 条
  • [41] Effect of poly(ethylene glycol) molecular weight on tensile and swelling properties of oligo(poly(ethylene glycol) fumarate) hydrogels for cartilage tissue engineering
    Temenoff, JS
    Athanasiou, KA
    LeBaron, RG
    Mikos, AG
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 59 (03): : 429 - 437
  • [42] POLY(ETHYLENE-TEREPHTHALATE) COPOLYMERS WITH A SMALLER AMOUNT OF POLY(ETHYLENE GLYCOL)S AND POLY(BUTYLENE GLYCOL)S
    KIYOTSUKURI, T
    MASUDA, T
    TSUTSUMI, N
    SAKAI, W
    NAGATA, M
    POLYMER, 1995, 36 (13) : 2629 - 2635
  • [43] Poly(ethylene glycol)-poly(tetrahydrofuran)-poly(ethylene glycol) triblock copolymer: Synthesis, crystallization behavior and novel morphology
    Fan, W. W.
    Fan, X. D.
    Tian, W.
    Liao, X. Q.
    Zhang, W. B.
    Mu, C. G.
    Kong, J.
    EXPRESS POLYMER LETTERS, 2013, 7 (05): : 416 - 430
  • [44] Synthesis of mesoporous silica by templating of amphiphilic poly (ethylene glycol)-block-poly (propylene glycol)-block-poly(ethylene glycol)
    Cui, XG
    Cho, WJ
    Ha, CS
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2000, 353 : 309 - 316
  • [45] Identification of Poly(ethylene glycol) and Poly(ethylene glycol)-Based Detergents Using Peptide Search Engines
    Ahmadi, Shiva
    Winter, Dominic
    ANALYTICAL CHEMISTRY, 2018, 90 (11) : 6594 - 6600
  • [46] Diffusion procedure of poly(ethylene glycol) segregated phase in the film of poly(ethylene glycol) /polyethylene blends
    Qian, Hao
    Lin, Zhi-Yong
    Zhang, Ying-Xue
    Gaofenzi Cailiao Kexue Yu Gongcheng/Polymeric Materials Science and Engineering, 2006, 22 (03): : 167 - 170
  • [47] Micellization of Aminoterminated Poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) in the Presence of Hyaluronic Acid
    Neffe, Axel T.
    Santan, Harshal D.
    Kamlage, Stefan
    Gottschalk, Benjamin
    Lendlein, Andreas
    MACROMOLECULAR SYMPOSIA, 2014, 345 (01) : 91 - 97
  • [48] REDOX-LABELED POLY(ETHYLENE GLYCOL) USED AS A DIFFUSION PROBE IN POLY(ETHYLENE GLYCOL) MELTS
    HAAS, O
    VELASQUEZ, C
    PORAT, Z
    MURRAY, RW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 165 - PHYS
  • [49] Measurement of Poly(ethylene glycol) by Cell-Based Anti-poly(ethylene glycol) ELISA
    Chuang, Kuo-Hsiang
    Tzou, Shey-Cherng
    Cheng, Ta-Chun
    Kao, Chien-Han
    Tseng, Wei-Lung
    Shiea, Jentaie
    Liao, Kuang-Wen
    Wang, Yun-Ming
    Chang, Ya-Chen
    Huang, Bo-Jyun
    Wu, Chang-Jer
    Chu, Pei-Yu
    Roffler, Steve R.
    Cheng, Tian-Lu
    ANALYTICAL CHEMISTRY, 2010, 82 (06) : 2355 - 2362
  • [50] Effect of poly(ethylene glycol)-polyhedral oligomeric silsesquioxanes on the crystallization kinetics and morphology of biodegradable poly(ethylene succinate)