Feasibility of patient-specific quality assurance (PSQA) for real-time robotic stereotactic body radiotherapy (SBRT) based on tumor motion traces

被引:0
作者
Xu, Qianyi [1 ,2 ]
Fan, Jiajin [1 ]
Vinogradskiy, Yevgeniy [2 ]
Chawla, Ashish K. [1 ]
Kubicek, Gregory [3 ]
Yang, Haihua [4 ]
Huynh, Kiet [1 ]
LaCouture, Tamara [2 ]
Grimm, Jimm [5 ]
Nie, Wei [1 ]
机构
[1] Inova Schar Canc Inst, Dept Adv Radiat Oncol & Proton Therapy, Fairfax, VA USA
[2] Thomas Jefferson Univ, Dept Radiat Oncol, 111 South 11th St, Philadelphia, PA 19107 USA
[3] Univ Miami, Dept Radiat Oncol, Miami, FL USA
[4] Taizhou Hosp, Dept Radiat Oncol, Taizhou, Zhejiang, Peoples R China
[5] Dept Radiat Oncol, Wellstar Hlth Syst, Marietta, GA USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 08期
关键词
CyberKnife; diode array; motion platform; PSQA; synchrony; RADIATION-THERAPY; TRACKING SYSTEM; ACCURACY; SRS;
D O I
10.1002/acm2.14352
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design a patient specific quality assurance (PSQA) process for the CyberKnife Synchrony system and quantify its dosimetric accuracy using a motion platform driven by patient tumor traces with rotation. Methods: The CyberKnife Synchrony system was evaluated using a motion platform (MODUSQA) and a SRS MapCHECK phantom. The platform was programed to move in the superior-inferior (SI) direction based on tumor traces. The detector array housed by the StereoPhan was placed on the platform. Extra rotational angles in pitch (head down, 4.0 degrees +/- 0.15 degrees or 1.2 degrees +/- 0.1 degrees) were added to the moving phantom to examine robot capability of angle correction during delivery. A total of 15 Synchrony patients were performed SBRT PSQA on the moving phantom. All the results were benchmarked by the PSQA results based on static phantom. Results: For smaller pitch angles, the mean gamma passing rates were 99.75% +/- 0.87%, 98.63% +/- 2.05%, and 93.11% +/- 5.52%, for 3%/1 mm, 2%/1 mm, and 1%/1 mm, respectively. Large discrepancy in the passing rates was observed for different pitch angles due to limited angle correction by the robot. For larger pitch angles, the corresponding mean passing rates were dropped to 93.00% +/- 10.91%, 88.05% +/- 14.93%, and 80.38% +/- 17.40%. When comparing with the static phantom, no significant statistic difference was observed for smaller pitch angles (p = 0.1 for 3%/1 mm), whereas a larger statistic difference was observed for larger pitch angles (p < 0.02 for all criteria). All the gamma passing rates were improved, if applying shift and rotation correction. Conclusions: The significance of this work is that it is the first study to benchmark PSQA for the CyberKnife Synchrony system using realistically moving phantoms with rotation. With reasonable delivery time, we found it may be feasible to perform PSQA for Synchrony patients with a realistic breathing pattern.
引用
收藏
页数:9
相关论文
共 30 条
  • [21] A phase I/II study on stereotactic body radiotherapy with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm for lung tumors
    Hiromitsu Iwata
    Satoshi Ishikura
    Taro Murai
    Michio Iwabuchi
    Mitsuhiro Inoue
    Koshi Tatewaki
    Seiji Ohta
    Naoki Yokota
    Yuta Shibamoto
    [J]. International Journal of Clinical Oncology, 2017, 22 : 706 - 714
  • [22] Stereotactic body radiotherapy using gated radiotherapy with real-time tumor-tracking for stage I non-small cell lung cancer
    Inoue, Tetsuya
    Katoh, Norio
    Onimaru, Rikiya
    Shimizu, Shinichi
    Tsuchiya, Kazuhiko
    Suzuki, Ryusuke
    Sakakibara-Konishi, Jun
    Shinagawa, Naofumi
    Oizumi, Satoshi
    Shirato, Hiroki
    [J]. RADIATION ONCOLOGY, 2013, 8
  • [23] Optimization based trajectory planning for real-time 6DoF robotic patient motion compensation systems
    Liu, Xinmin
    Wiersma, Rodney D.
    [J]. PLOS ONE, 2019, 14 (01):
  • [24] A prospective study on the effect of tumor shrinkage on exit fluence gamma pass rate in high precision radiotherapy and influence of phantom setup error in patient-specific quality assurance
    Tiwari, Arnav
    Das, Saikat
    Pandey, Vindhyavasini P.
    Kharade, Vipin
    Gupta, Manish
    Pasricha, Rajesh
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (03) : 935 - 942
  • [25] Image-Guided Liver Stereotactic Body Radiotherapy Using VMAT and Real-Time Adaptive Tumor Gating: Evaluation of the Efficacy and Toxicity for Hepatocellular Carcinoma
    Cantaloube, Marie
    Castan, Florence
    Creoff, Morgane
    Prunaretty, Jessica
    Bordeau, Karl
    Michalet, Morgan
    Assenat, Eric
    Guiu, Boris
    Pageaux, Georges-Philippe
    Ychou, Marc
    Ailleres, Norbert
    Fenoglietto, Pascal
    Azria, David
    Riou, Olivier
    [J]. CANCERS, 2021, 13 (19)
  • [26] Feasibility, detectability and clinical experience with platinum fiducial seeds for MRI/CT fusion and real-time tumor tracking during CyberKnife((R)) stereotactic ablative radiotherapy
    Nair, Vimoj J.
    Szanto, Janos
    Vandervoort, Eric
    Henderson, Elizabeth
    Avruch, Leonard
    Malone, Shawn
    Pantarotto, Jason R.
    [J]. JOURNAL OF RADIOSURGERY AND SBRT, 2015, 3 (04): : 315 - 323
  • [27] Clinical assessment of coiled fiducial markers as internal surrogates for hepatocellular carcinomas during gated stereotactic body radiotherapy with a real-time tumor-tracking system
    Hanazawa, Hideki
    Takahashi, Shotaro
    Shiinoki, Takehiro
    Park, Sung Chul
    Yuasa, Yuki
    Koike, Masahiro
    Kawamura, Shinji
    Shibuya, Keiko
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 (01) : 43 - 48
  • [28] Clinical outcomes of stage I and IIA non-small cell lung cancer patients treated with stereotactic body radiotherapy using a real-time tumor-tracking radiotherapy system
    Katoh, Norio
    Soda, Itaru
    Tamamura, Hiroyasu
    Takahashi, Shotaro
    Uchinami, Yusuke
    Ishiyama, Hiromichi
    Ota, Kiyotaka
    Inoue, Tetsuya
    Onimaru, Rikiya
    Shibuya, Keiko
    Hayakawa, Kazushige
    Shirato, Hiroki
    [J]. RADIATION ONCOLOGY, 2017, 12
  • [29] Dosimetric comparison of Synchrony® real-time motion tracking treatment plans between CyberKnife robotic radiosurgery and Radixact system for stereotactic body radiation therapy of lung and prostate cancer
    Kong, C. W.
    Chiu, T. L.
    Geng, H.
    Lam, W. W.
    Yang, B.
    Cheung, C. W.
    Yu, S. K.
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [30] Intrafractional Diaphragm Variations During Breath-Hold Stereotactic Body Radiotherapy for a Liver Tumor Based on Real-Time Registration Between Kilovoltage Projection Streaming and Digitally Reconstructed Radiograph Images: A Case Report
    Katano, Atsuto
    Nozawa, Yuki
    Minamitani, Masanari
    Ohira, Shingo
    Nakagawa, Keiichi
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)