Preparation and application of a high-performance vanadium oxide thermosensitive film

被引:0
作者
Ma Z. [1 ]
Wang Y. [1 ]
Wang C. [1 ]
Ye F. [1 ]
Gao J. [1 ]
Huang L. [1 ]
机构
[1] Wuhan Guide Infrared Co., Ltd., Wuhan
来源
Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering | 2021年 / 50卷 / 02期
关键词
Reactive magnetron sputtering; TCR; Uncooled infrared focal plane detector; Vanadium oxide film;
D O I
10.3788/IRLA20200349
中图分类号
学科分类号
摘要
A method for preparing high performance vanadium oxide thermosensitive thin films and its application were reported. Using reactive magnetron sputtering film deposition technology, the preparation process of vanadium oxide thin films was optimized by changing the sputtering power during the deposition of vanadium oxide thermosensitive thin films, the deposition rate of vanadium atoms was adjusted when they touched the surface of the substrate after being sputtered. At the same time, the equipment was modified and upgraded, that is, a control power supply outside the vanadium sputtering chamber was added to accurately control the sputtering voltage and oxygen partial pressure and other parameters to accurately control the current density in the reaction process. A vanadium oxide film with a sheet resistance of 500 kΩ/□ and a temperature coefficient of resistance (TCR) of −2.7% K−1 was prepared. The experimental results show that the noise equivalent temperature difference (NETD) performance of uncooled infrared focal plane detector made of high-performance vanadium oxide thermal sensitive film is reduced by 30% and the noise is reduced by 28%. The overall performance of the uncooled focal plane detector has been improved significantly. Copyright ©2021 Infrared and Laser Engineering. All rights reserved.
引用
收藏
相关论文
共 10 条
  • [1] Tissot J., IR detection with uncooled sensors, Infrared Physics & Technology, 46, 1-2, pp. 147-153, (2004)
  • [2] Song W B., Fabrication of adaptive microbolometers, Proceedings of SPIE the International Society for Optical Engineering, 5406, pp. 566-576, (2004)
  • [3] Cole B, Horning R, Johnson B, Et al., High performance infrared detector arrays using thin film microstructures, Proceedings of 1994 IEEE International Symposium on Applications of Ferroelectrics, pp. 653-656, (1994)
  • [4] Lei Shuyu, Fang Hui, Liu Jun, Et al., Research on domestic 640×512 uncooled VOx infrared focal plane array, Infrared Technology, 35, 12, pp. 759-763, (2013)
  • [5] Becker S, Imperinetti P, Yon J J, Et al., Latest pixel size reduction of uncooled IR-FPA at CEA, LETI, Proceedings of SPIE the International Society for Optical Engineering, 8541, (2012)
  • [6] Li Huagao, Yang Ziwen, Liu Shuang, Preparation of VOx films for uncooled infrared detectors, Semiconductor Optoelectronics, 22, 1, pp. 38-40, (2001)
  • [7] Niklaus F, Vieider C, Jakobsen H., MEMS-based uncooled infrared bolometer arrays: a review, Proc SPIE, 6836, (2008)
  • [8] Hay A K A., Large format VOx microbolometer UFPA development at ITC, Proceedings of SPIE-The International Society for Optical Engineering, 6295, (2006)
  • [9] Zhao Y, Mao M Y, Horowitz R, Et al., Optomechanical uncooled infrared imaging system: design, microfabrication, and performance, Journal of Microelectromechanical Systems, 11, 2, pp. 136-146, (2002)
  • [10] Feng Tao, Jin Weiqi, Si Junjie, Uncooled infrared FPA−A review and forecast, Infrared Technology, 37, 3, pp. 177-184, (2015)