Linearizing the vertical scale of an interferometric microscope and its effect on step-height measurement

被引:0
|
作者
Germer, Thomas A. [1 ]
Renegar, T. Brian [1 ]
Griesmann, Ulf [1 ]
Soons, Johannes A. [1 ]
机构
[1] Natl Inst Stand & Technol, Sensor Sci Div, Gaithersburg, MD 20899 USA
关键词
microscope; linearization; interferometer; calibration; step-height; coherence scanning interferometer; CALIBRATION;
D O I
10.1088/2051-672X/ad44bb
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The vertical scale calibration of an interferometric microscope is important for establishing traceability of surface topography measurements to the International System of Units (SI) unit of length, the meter. Building on the calibration procedure for the amplification coefficient developed by de Groot and Beverage [Proc. SPIE 9526, 952610 (2015)], this paper describes a calibration procedure that yields the response curve for the entire vertical scan motion of a coherent scanning interferometric microscope. The method requires only a flat mirror as an artifact, a narrow band spectral filter, an aperture to reduce the effective numerical aperture, and the ability to raise and lower the microscope head so that the center of the interferogram can be varied within the scan range. The local frequency of the interferogram is determined by fitting sections of the interferogram to a sinusoidal function. The nonlinearity determined from the local frequency data can be used to estimate the uncertainty in uncorrected vertical height measurements. We describe how optical profile data can be corrected for nonlinearity due to dynamic effects in the scan motion and show that the correction improves the reproducibility of step height measurements by at least a factor of three and close to that of the repeatability.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Step-height measurement by means of a dual-frequency interferometric confocal microscope
    Lin, DJ
    Liu, ZY
    Zhang, R
    Yan, JQ
    Yin, CY
    Xu, Y
    APPLIED OPTICS, 2004, 43 (07) : 1472 - 1479
  • [2] Shearing interference microscope for step-height measurements
    Hung-Xuan Trinh
    Lin, Shyh-Tsong
    Chen, Liang-Chia
    Yeh, Sheng-Lih
    Chen, Chin-Sheng
    Hong-Hai Hoang
    JOURNAL OF MICROSCOPY, 2017, 266 (02) : 178 - 185
  • [3] RESOLVING INTERFEROMETRIC STEP-HEIGHT MEASUREMENT AMBIGUITIES USING A-PRIORI INFORMATION
    GREIVENKAMP, JE
    SULLIVAN, KG
    PALUM, RJ
    OPTICAL ENGINEERING, 1991, 30 (11) : 1821 - 1824
  • [4] Simultaneous three-dimensional step-height measurement and high-resolution tomographic imaging with a spectral interferometric microscope
    Mehta, Dalip Singh
    Sugai, Masaya
    Hinosugi, Hideki
    Saito, Shohei
    Takeda, Mitsuo
    Kurokawa, Takashi
    Takahashi, Hideki
    Ando, Masahito
    Shishido, Masataka
    Yoshizawa, Tetsuo
    Applied Optics, 2002, 41 (19): : 3874 - 3885
  • [5] Simultaneous three-dimensional step-height measurement and high-resolution tomographic imaging with a spectral interferometric microscope
    Mehta, DS
    Sugai, M
    Hinosugi, H
    Saito, S
    Takeda, M
    Kurokawa, T
    Takahashi, H
    Ando, M
    Shishido, M
    Yoshizawa, T
    APPLIED OPTICS, 2002, 41 (19) : 3874 - 3885
  • [6] Two-wavelength Talbot effect and its application for three-dimensional step-height measurement
    Mehta, Dalip Singh
    Dubey, Satish Kumar
    Shakher, Chandra
    Takeda, Mitsuo
    APPLIED OPTICS, 2006, 45 (29) : 7602 - 7609
  • [7] Wavelength-scanning Talbot effect and its application for arbitrary three-dimensional step-height measurement
    Dubey, Satish Kumar
    Mehta, Dalip Singh
    Roy, Amitava
    Shakher, Chandra
    OPTICS COMMUNICATIONS, 2007, 279 (01) : 13 - 19
  • [8] Flexible Digital Fringe Projection System for Step-height Measurement
    Zhang, Song
    Oliver, James
    INTERNATIONAL CONFERENCE ON ADVANCED PHASE MEASUREMENT METHODS IN OPTICS AN IMAGING, 2010, 1236 : 433 - 437
  • [9] Spectral interferometric microscope with tandem liquid-crystal Fabry-Perot interferometers for extension of the dynamic range in three-dimensional step-height measurement
    Mehta, DS
    Hinosugi, H
    Saito, S
    Takeda, M
    Kurokawa, T
    Takahashi, H
    Ando, M
    Shishido, M
    Yoshizawa, T
    APPLIED OPTICS, 2003, 42 (04) : 682 - 690
  • [10] Step height measurement by means of common-path heterodyne interferometric confocal microscope
    Liu, ZY
    Zhang, R
    Lin, DJ
    Yan, JQ
    Yin, CY
    Ye, XY
    Xu, J
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3, 2004, : 170 - 174