Axial Compression Behavior of Circular Seawater and Sea Sand Concrete Columns Reinforced with Hybrid GFRP-Stainless Steel Bars

被引:3
作者
Wang, Hongwei [1 ]
Xu, Jinjin [2 ]
Zhao, Jiuzhang [3 ]
Han, Xiaoyan [3 ]
Pan, Kaiming [3 ]
Yu, Rena C. [4 ]
Wu, Zhimin [1 ]
机构
[1] Zhejiang Univ Sci & Technol, Sch Civil Engn & Architecture, Hangzhou 310023, Peoples R China
[2] Tianjin Renai Coll, Sch Civil Engn, Tianjin 301636, Peoples R China
[3] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[4] Univ Castilla La Mancha, ETSI Caminos Canales & Puertos, Ciudad Real 13001, Spain
基金
中国国家自然科学基金;
关键词
hybrid reinforcement; column; axial compression; ductility; STRENGTH; CAPACITY; TESTS;
D O I
10.3390/ma17081767
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The ductility of FRP-reinforced concrete structures is reduced by the brittleness of FRP bars. To address this issue, this study employs the hybrid reinforcement of stainless steel (SS) and GFRP bars to enhance the ductility of concrete columns. A total of 21 axially compressed seawater and sea sand concrete (SWSSC) circular columns are fabricated, including 15 hybrid GFRP and SS bar-reinforced SWSSC (GFRP-SS-SWSSC) columns, 3 GFRP bar-reinforced SWSSC (GFRP-SWSSC) columns, and 3 SS bar-reinforced SWSSC (SS-SWSSC) columns. The test results are analyzed in terms of failure mode, load-axial displacement curve, bearing capacity, and ductility. Results show that GFRP-SWSSC columns suffer brittle failure, while GFRP-SS-SWSSC columns and SS-SWSSC columns demonstrate ductile failure characteristics. Furthermore, the hybrid reinforcement contributes to an improvement in the bearing capacity of the columns. A calculation equation for the bearing capacity of axially compressed columns was established, providing reasonable predictions of bearing capacities, with a design compressive strain of 2000 mu epsilon for GFRP bars. It was found that hybrid reinforcement enhanced the ductility of GFRP-SWSSC columns. In addition, when the percentage of the SS reinforcement ratio reaches 50%, the ductility indexes of the GFRP-SS-SWSSC columns closely approach those of the SS-SWSSC columns.
引用
收藏
页数:23
相关论文
共 35 条
[1]   Strength and Axial Behavior of Circular Concrete Columns Reinforced with CFRP Bars and Spirals [J].
Afifi, Mohammad Z. ;
Mohamed, Hamdy M. ;
Benmokrane, Brahim .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (02)
[2]   Axial Capacity of Circular Concrete Columns Reinforced with GFRP Bars and Spirals [J].
Afifi, Mohammad Z. ;
Mohamed, Hamdy M. ;
Benmokrane, Brahim .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (01)
[3]  
[Anonymous], 2019, 500812019 GBT NAT ST
[4]  
[Anonymous], 2011, ASTM D7205
[5]  
[Anonymous], 2010, Metallic Materials-Tensile Testing-Part 1: Method of Test at Room Temperature
[6]  
[Anonymous], 2015, GB 50010-2010
[7]  
[Anonymous], 2011, 146842011 GBT NAT ST
[8]  
De Luca A, 2010, ACI STRUCT J, V107, P589
[9]   Structural performance and serviceability of concrete beams reinforced with hybrid (GFRP and steel) bars [J].
El Refai, Ahmed ;
Abed, Farid ;
Al-Rahmani, Abdullah .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 96 :518-529
[10]   Circular Concrete Columns and Beams Reinforced with GFRP Bars and Spirals under Axial, Eccentric, and Flexural Loading [J].
Elchalakani, Mohamed ;
Dong, Minhao ;
Karrech, Ali ;
Ali, Mohamed Sadakkathulla Mohamed ;
Huo, Jing-Si .