Registration accuracy comparing different rendering techniques on local vs external virtual 3D liver model reconstruction for vascular landmark setting by intraoperative ultrasound in augmented reality navigated liver resection

被引:0
作者
Sheriff, Nonkoh J. [1 ,2 ]
Thomas, Michael [1 ]
Bunck, Alexander C. [3 ]
Peterhans, Matthias [4 ]
Datta, Rabi Raj [1 ]
Hellmich, Martin [5 ]
Bruns, Christiane J. [1 ]
Stippel, Dirk Ludger [1 ]
Wahba, Roger [1 ,2 ]
机构
[1] Univ Cologne, Univ Hosp Cologne, Fac Med, Dept Gen Visceral Canc & Transplant Surg, D-50937 Cologne, Germany
[2] Helios Hosp Berlin Buch, Dept Gen Visceral & Oncol Surg, Berlin, Germany
[3] Univ Cologne, Univ Hosp Cologne, Inst Diagnost & Intervent Radiol, Fac Med, Cologne, Germany
[4] CAScinat AG, Steigerhubelstr 3, CH-3008 Bern, Switzerland
[5] Univ Cologne, Univ Hosp Cologne, Med Fac, Inst Med Stat & Computat Biol, Cologne, Germany
关键词
Augmented reality; Intraoperative 3D navigation; Innovation; Liver surgery; Registration accuracy; Segmentation; IMAGE; TIME; METASTASES; ABLATION; SURGERY; SYSTEM;
D O I
10.1007/s00423-024-03456-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose Augmented reality navigation in liver surgery still faces technical challenges like insufficient registration accuracy. This study compared registration accuracy between local and external virtual 3D liver models (vir3DLivers) generated with different rendering techniques and the use of the left vs right main portal vein branch (LPV vs RPV) for landmark setting. The study should further examine how registration accuracy behaves with increasing distance from the ROI. Methods Retrospective registration accuracy analysis of an optical intraoperative 3D navigation system, used in 13 liver tumor patients undergoing liver resection/thermal ablation. Results 109 measurements in 13 patients were performed. Registration accuracy with local and external vir3DLivers was comparable (8.76 +/- 0.9 mm vs 7.85 +/- 0.9 mm; 95% CI = -0.73 to 2.55 mm; p = 0.272). Registrations via the LPV demonstrated significantly higher accuracy than via the RPV (6.2 +/- 0.85 mm vs 10.41 +/- 0.99 mm, 95% CI = 2.39 to 6.03 mm, p < 0.001). There was a statistically significant positive but weak correlation between the accuracy (d(Feature)) and the distance from the ROI (d(ROI)) (r = 0.298; p = 0.002). Conclusion Despite basing on different rendering techniques both local and external vir3DLivers have comparable registration accuracy, while LPV-based registrations significantly outperform RPV-based ones in accuracy. Higher accuracy can be assumed within distances of up to a few centimeters around the ROI.
引用
收藏
页数:9
相关论文
共 29 条
[1]   Intraoperative image-guided navigation system: development and applicability in 65 patients undergoing liver surgery [J].
Banz, Vanessa M. ;
Mueller, Philip C. ;
Tinguely, Pascale ;
Inderbitzin, Daniel ;
Ribes, Delphine ;
Peterhans, Matthias ;
Candinas, Daniel ;
Weber, Stefan .
LANGENBECKS ARCHIVES OF SURGERY, 2016, 401 (04) :495-502
[2]   Computer planned, image-guided combined resection and ablation for bilobar colorectal liver metastases [J].
Banz, Vanessa M. ;
Baechtold, Matthias ;
Weber, Stefan ;
Peterhans, Matthias ;
Inderbitzin, Daniel ;
Candinas, Daniel .
WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (40) :14992-14996
[3]   Complete response of colorectal liver metastases after chemotherapy:: Does it mean cure? [J].
Benoist, Stephane ;
Brouquet, Antoine ;
Penna, Christophe ;
Julie, Catherine ;
El Hajjam, Mostafa ;
Chagnon, Sophie ;
Mitry, Emmanuel ;
Rougier, Philippe ;
Nordlinger, Bernard .
JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (24) :3939-3945
[4]   Evaluation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound [J].
Clements, Logan W. ;
Collins, Jarrod A. ;
Weis, Jared A. ;
Simpson, Amber L. ;
Adams, Lauryn B. ;
Jarnagin, William R. ;
Miga, Michael I. .
JOURNAL OF MEDICAL IMAGING, 2016, 3 (01)
[5]   Organ Surface Deformation Measurement and Analysis in Open Hepatic Surgery: Method and Preliminary Results From 12 Clinical Cases [J].
Clements, Logan W. ;
Dumpuri, Prashanth ;
Chapman, William C. ;
Dawant, Benoit M. ;
Galloway, Robert L. ;
Miga, Michael I. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (08) :2280-2289
[6]   Incidence, patterns, and clinical relevance of variant portal vein anatomy [J].
Covey, AM ;
Brody, LA ;
Getrajdman, GI ;
Sofocleous, CT ;
Brown, KT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (04) :1055-1064
[7]  
Dirisamer A, 2005, RADIOLOGE, V45, P8, DOI 10.1007/s00117-004-1150-5
[8]   Increased use of parenchymal-sparing surgery for bilateral liver metastases from colorectal cancer is associated with improved mortality without change in oncologic outcome -: Trends in treatment over time in 440 patients [J].
Gold, Jason S. ;
Are, Chandrakanth ;
Kornprat, Peter ;
Jarnagin, William R. ;
Gonen, Mithat ;
Fong, Yuman ;
DeMatteo, Ronald P. ;
Blumgart, Leslie H. ;
D'Angelica, Michael .
ANNALS OF SURGERY, 2008, 247 (01) :109-117
[9]   How Much Remnant Is Enough in Liver Resection? [J].
Guglielmi, Alfredo ;
Ruzzenente, Andrea ;
Conci, Simone ;
Valdegamberi, Alessandro ;
Iacono, Calogero .
DIGESTIVE SURGERY, 2012, 29 (01) :6-17
[10]   Intraoperative ultrasound in visceral surgery [J].
Hackl, C. ;
Bitterer, F. ;
Platz Batista da Silva, N. ;
Jung, E. M. ;
Schlitt, H. J. .
CHIRURG, 2020, 91 (06) :474-480