Effects of increasing tidal volume and end-expiratory lung volume on induced bronchoconstriction in healthy humans

被引:0
|
作者
Gobbi, Alessandro [1 ,2 ]
Antonelli, Andrea [3 ]
Dellaca, Raffaele [1 ]
Pellegrino, Giulia M. [4 ]
Pellegrino, Riccardo [5 ]
Fredberg, Jeffrey J. [6 ]
Solway, Julian [7 ]
Brusasco, Vito [8 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, I-20133 Milan, Italy
[2] Restech Srl, I-20124 Milan, Italy
[3] ASO S Croce & Carle, Allergol & Fisiopatol Resp, I-12100 Cuneo, Italy
[4] Casa Cura Policlin, Dipartimento Sci Neuroriabilitat, Milan, Italy
[5] Ctr Med Pneumol Torino, I-10129 Turin, Italy
[6] Harvard Univ, Harvard T H Chan Sch Publ Hlth, Boston, MA 02115 USA
[7] Univ Chicago, Dept Med, Chicago, IL USA
[8] Univ Genoa, Dipartimento Med Sperimentale, Genoa, Italy
关键词
Lung volume; Tidal breathing; Airway caliber; Oscillometry; Methacholine; AIRWAY SMOOTH-MUSCLE; RESPIRATORY IMPEDANCE; LENGTH ADAPTATION; METHACHOLINE; RESISTANCE; RESPONSIVENESS; FREQUENCY; MECHANICS; BREATH;
D O I
10.1186/s12931-024-02909-9
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
BackgroundIncreasing functional residual capacity (FRC) or tidal volume (VT) reduces airway resistance and attenuates the response to bronchoconstrictor stimuli in animals and humans. What is unknown is which one of the above mechanisms is more effective in modulating airway caliber and whether their combination yields additive or synergistic effects. To address this question, we investigated the effects of increased FRC and increased VT in attenuating the bronchoconstriction induced by inhaled methacholine (MCh) in healthy humans.MethodsNineteen healthy volunteers were challenged with a single-dose of MCh and forced oscillation was used to measure inspiratory resistance at 5 and 19 Hz (R5 and R19), their difference (R5-19), and reactance at 5 Hz (X5) during spontaneous breathing and during imposed breathing patterns with increased FRC, or VT, or both. Importantly, in our experimental design we held the product of VT and breathing frequency (BF), i.e, minute ventilation (VE) fixed so as to better isolate the effects of changes in VT alone.ResultsTripling VT from baseline FRC significantly attenuated the effects of MCh on R5, R19, R5-19 and X5. Doubling VT while halving BF had insignificant effects. Increasing FRC by either one or two VT significantly attenuated the effects of MCh on R5, R19, R5-19 and X5. Increasing both VT and FRC had additive effects on R5, R19, R5-19 and X5, but the effect of increasing FRC was more consistent than increasing VT thus suggesting larger bronchodilation. When compared at iso-volume, there were no differences among breathing patterns with the exception of when VT was three times larger than during spontaneous breathing.ConclusionsThese data show that increasing FRC and VT can attenuate induced bronchoconstriction in healthy humans by additive effects that are mainly related to an increase of mean operational lung volume. We suggest that static stretching as with increasing FRC is more effective than tidal stretching at constant VE, possibly through a combination of effects on airway geometry and airway smooth muscle dynamics.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomography
    Grivans, C.
    Lundin, S.
    Stenqvist, O.
    Lindgren, S.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (09) : 1068 - 1077
  • [22] EFFECTS OF INCREASED END-EXPIRATORY LUNG-VOLUME ON BREATHING IN AWAKE PONIES
    BRICE, AG
    FORSTER, HV
    PAN, LG
    LOWRY, TF
    MURPHY, CL
    MEAD, J
    JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (02) : 715 - 725
  • [23] The Influence of Increased End-Expiratory Lung Volume on Pharyngeal Collapsibility
    Owens, R. L.
    Campana, L. M.
    Stevenson, K.
    Hess, L.
    White, D. P.
    Malhotra, A.
    Jordan, A. S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [24] Lung mechanics and end-expiratory lung volume during hypoxia in rats
    Bonora, M
    Vizek, M
    JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (01) : 15 - 21
  • [25] Effect of End-Expiratory Lung Volume (EELV) on Upper Airway Collapsibility (UAC) in Sleeping Humans
    Squier, S. B.
    Patil, S. P.
    Schneider, H.
    Smith, P. L.
    Schwartz, A. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [26] REGULATION OF END-EXPIRATORY LUNG-VOLUME DURING EXERCISE
    HENKE, KG
    SHARRATT, M
    PEGELOW, D
    DEMPSEY, JA
    JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (01) : 135 - 146
  • [27] REGULATION OF END-EXPIRATORY LUNG-VOLUME DURING EXERCISE
    HENKE, KG
    SHARRATT, M
    PEGELOW, D
    DEMPSEY, J
    FEDERATION PROCEEDINGS, 1987, 46 (03) : 491 - 491
  • [28] The influence of end-expiratory lung volume on measurements of pharyngeal collapsibility
    Owens, Robert L.
    Malhotra, Atul
    Eckert, Danny J.
    White, David P.
    Jordan, Amy S.
    JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (02) : 445 - 451
  • [29] Control of end-expiratory lung volume:: component of the control of breathing
    Vízek, M
    JOURNAL OF PHYSIOLOGY-LONDON, 1998, 511P : 42S - 43S
  • [30] Estimation of end-expiratory lung volume variations by optoelectronic plethysmography
    Dellacà, RL
    Aliverti, A
    Pelosi, P
    Carlesso, E
    Chiumello, D
    Pedotti, A
    Gattinoni, L
    CRITICAL CARE MEDICINE, 2001, 29 (09) : 1807 - 1811