摘要
Deep learning has achieved notable performance in the denoising task of low-quality medical images and the detection task of lesions, respectively. However, existing low-quality medical image denoising approaches are disconnected from the detection task of lesions. Intuitively, the quality of denoised images will influence the lesion detection accuracy that in turn can be used to affect the denoising performance. To this end, we propose a play-andplug medical image denoising framework, namely Lesion-Inspired Denoising Network (LIDnet), to collaboratively improve both denoising performance and detection accuracy of denoised medical images. Specifically, we propose to insert the feedback of downstream detection task into existing denoising framework by jointly learning a multi-loss objective. Instead of using perceptual loss calculated on the entire feature map, a novel region-of-interest (ROI) perceptual loss induced by the lesion detection task is proposed to further connect these two tasks. To achieve better optimization for overall framework, we propose a customized collaborative training strategy for LIDnet. On consideration of clinical usability and imaging characteristics, three low-dose CT images datasets are used to evaluate the effectiveness of the proposed LIDnet. Experiments show that, by equipping with LIDnet, both of the denoising and lesion detection performance of baseline methods can be significantly improved.
引用
收藏
页码:3283 / 3292
页数:10
相关论文
共 54 条
[1]  
Ahmed Hanan Saleh S., 2011, Journal of Computer Sciences, V7, P1831, DOI 10.3844/jcssp.2011.1831.1838
[2]   Routine low-radiation-dose coronary computed tomography angiography [J].
Al-Mallah, Mouaz H. ;
Aljizeeri, Ahmed ;
Alharthi, Mohsen ;
Alsaileek, Ahmed .
EUROPEAN HEART JOURNAL SUPPLEMENTS, 2014, 16 (0B) :B12-B16
[3]  
Anantharaman R, 2018, IEEE INT C BIOINFORM, P2197, DOI 10.1109/BIBM.2018.8621112
[4]  
[Anonymous], 2021, MULTIMEDIA TOOLS APP, DOI DOI 10.1109/IRI51335.2021.00007
[5]  
[Anonymous], IEEE ACCESS
[6]  
[Anonymous], NAT MACH INTELL
[7]   Unsupervised Multi-Modal Image Registration via Geometry Preserving Image-to-Image Translation [J].
Arar, Moab ;
Ginger, Yiftach ;
Danon, Dov ;
Bermano, Amit H. ;
Cohen-Or, Daniel .
2020 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2020), 2020, :13407-13416
[8]  
Arjovsky M, 2017, PR MACH LEARN RES, V70
[9]   Ray Contribution Masks for Structure Adaptive Sinogram Filtering [J].
Balda, Michael ;
Hornegger, Joachim ;
Heismann, Bjoern .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (06) :1228-1239
[10]  
Cavaro-Menard Christine, 2010, 2010 2nd European Workshop on Visual Information Processing (EUVIP 2010), P277, DOI 10.1109/EUVIP.2010.5699147