Simultaneous Measurement of Local Pulse Wave Velocities in Radial Arteries Using a Soft Sensor Based on the Fiber Bragg Grating Technique

被引:2
作者
Wang, Jing [1 ,2 ,3 ]
Wang, Zhukun [1 ]
Zhang, Zijun [1 ]
Li, Peiyun [1 ]
Pan, Han [1 ]
Ren, Yong [2 ,4 ,5 ]
Hou, Tuo [4 ]
Wang, Chengbo [1 ,2 ]
Kwong, Chiew-Foong [1 ,3 ]
Zhang, Bei [6 ]
Yang, Sen [1 ,2 ]
Bie, Jing [7 ]
机构
[1] Univ Nottingham Ningbo China, Dept Elect & Elect Engn, Ningbo 315100, Peoples R China
[2] Univ Nottingham Ningbo China, Nottingham Ningbo China Beacons Excellence Res & I, Ningbo 315048, Peoples R China
[3] Univ Nottingham Ningbo China, Key Lab More Elect Aircraft Technol Zhejiang Prov, Ningbo 315100, Peoples R China
[4] Univ Nottingham Ningbo China, Dept Mech Mat & Mfg Engn, Ningbo 315100, Peoples R China
[5] Univ Nottingham Ningbo China, Key Lab More Elect Aircraft Technol Zhejiang Prov, Ningbo 315100, Peoples R China
[6] Beihang Univ, Dept Automat Sci & Elect Engn, 37 Xueyuan Rd, Beijing 100191, Peoples R China
[7] Univ Nottingham Ningbo China, Dept Civil Engn, Ningbo 315100, Peoples R China
关键词
fiber Bragg grating; pulse wave velocity; radial artery; cardiovascular disease; wearable sensor; soft sensor; arterial stiffness; NONINVASIVE METHOD; STIFFNESS; RISK; STROKE;
D O I
10.3390/mi15040507
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Arterial stiffness has been proved to be an important parameter in the evaluation of cardiovascular diseases, and Pulse Wave Velocity (PWV) is a strong indicator of arterial stiffness. Compared to regional PWV (PWV among different arteries), local PWV (PWV within a single artery) outstands in providing higher precision in indicating arterial properties, as regional PWVs are highly affected by multiple parameters, e.g., variations in blood vessel lengths due to individual differences, and multiple reflection effects on the pulse waveform. However, local PWV is less-developed due to its high dependency on the temporal resolution in synchronized signals with usually low signal-to-noise ratios. This paper presents a method for the noninvasive simultaneous measurement of two local PWVs in both left and right radial arteries based on the Fiber Bragg Grating (FBG) technique via correlation analysis of the pulse pairs at the fossa cubitalis and at the wrist. Based on the measurements of five male volunteers at the ages of 19 to 21 years old, the average left radial PWV ranged from 9.44 m/s to 12.35 m/s and the average right radial PWV ranged from 11.50 m/s to 14.83 m/s. What is worth mentioning is that a stable difference between the left and right radial PWVs was observed for each volunteer, ranging from 2.27 m/s to 3.04 m/s. This method enables the dynamic analysis of local PWVs and analysis of their features among different arteries, which will benefit the diagnosis of early-stage arterial stiffening and may bring more insights into the diagnosis of cardiovascular diseases.
引用
收藏
页数:13
相关论文
共 47 条
  • [1] Aortic Pulse Wave Velocity Improves Cardiovascular Event Prediction An Individual Participant Meta-Analysis of Prospective Observational Data From 17,635 Subjects
    Ben-Shlomo, Yoav
    Spears, Melissa
    Boustred, Chris
    May, Margaret
    Anderson, Simon G.
    Benjamin, Emelia J.
    Boutouyrie, Pierre
    Cameron, James
    Chen, Chen-Huan
    Cruickshank, J. Kennedy
    Hwang, Shih-Jen
    Lakatta, Edward G.
    Laurent, Stephane
    Maldonado, Joao
    Mitchell, Gary F.
    Najjar, Samer S.
    Newman, Anne B.
    Ohishi, Mitsuru
    Pannier, Bruno
    Pereira, Telmo
    Vasan, Ramachandran S.
    Shokawa, Tomoki
    Sutton-Tyrell, Kim
    Verbeke, Francis
    Wang, Kang-Ling
    Webb, David J.
    Hansen, Tine Willum
    Zoungas, Sophia
    McEniery, Carmel M.
    Cockcroft, John R.
    Wilkinson, Ian B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (07) : 636 - 646
  • [2] Determination of Aortic Characteristic Impedance and Total Arterial Compliance From Regional Pulse Wave Velocities Using Machine Learning: An in-silico Study
    Bikia, Vasiliki
    Rovas, Georgios
    Pagoulatou, Stamatia
    Stergiopulos, Nikolaos
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [3] Bramwell JC, 1922, LANCET, V1, P891
  • [4] A noninvasive method to estimate pulse wave velocity in arteries locally by means of ultrasound
    Brands, PJ
    Willigers, JM
    Ledoux, LAF
    Reneman, RS
    Hoeks, APG
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (09) : 1325 - 1335
  • [5] Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration
    Chen, W
    Kobayashi, T
    Ichikawa, S
    Takeuchi, Y
    Togawa, T
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) : 569 - 574
  • [6] Darwich M.A., 2015, J. Biomed. Sci. Eng., V8, P227, DOI [10.4236/jbise.2015.84022, DOI 10.4236/JBISE.2015.84022]
  • [7] Eguchi K, 2015, PULSE, V3, P190, DOI [10.1159/000443740, 10.1159/000443615]
  • [8] Pulse wave analysis and pulse wave velocity - A review of blood pressure interpretation 100 years after Korotkov
    Hirata, Kozo
    Kawakami, Masanobu
    O'Rourke, Michael F.
    [J]. CIRCULATION JOURNAL, 2006, 70 (10) : 1231 - 1239
  • [9] Hoctor RT, 2004, ULTRASON, P1492
  • [10] Skin-Coupled Personal Wearable Ambulatory Pulse Wave Velocity Monitoring System Using Microelectromechanical Sensors
    Hsu, Yu-Pin
    Young, Darrin J.
    [J]. IEEE SENSORS JOURNAL, 2014, 14 (10) : 3490 - 3497