Double implantation of Xen 45 gel stent in primary open-angle glaucoma: a pilot study

被引:1
作者
Grosso, Andrea [1 ,2 ]
Ceruti, Piero [3 ]
Garlasco, Jacopo [4 ]
Frohlich, Jacqueline [5 ]
Orione, Matteo [1 ]
Gugleta, Konstantin [5 ,6 ]
Fioretto, Mauro [1 ]
Calzetti, Giacomo [5 ,6 ]
机构
[1] ASL Alessandria Santo Spirito Hosp, Ophthalmol Unit, Casale Monferrato, Italy
[2] Ctr Macular Res, 73 Via Roma, San Mauro Torinese, Italy
[3] Univ Verona, Dept Neurol & Visual Sci, Eye Clin, Verona, Italy
[4] Univ Turin, Dept Publ Hlth & Paediat, Turin, Italy
[5] Univ Basel, Dept Ophthalmol, Basel, Switzerland
[6] Inst Mol & Clin Ophthalmol Basel, Basel, Switzerland
关键词
Xen 45 gel stent; Primary open-angle glaucoma; Double Xen; Minimally invasive glaucoma surgery; Ab externo; SURGERY; SAFETY;
D O I
10.1007/s10792-024-03153-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo describe the outcomes of double implantation of Xen 45 Gel Stent (Xen) using an ab externo approach with closed conjunctiva. MethodsRetrospective single-centre case series of primary open-angle glaucoma patients with at least six months of follow-up after implantation of a second Xen in the same eye via ab externo technique without conjunctival opening. ResultsEight pseudophakic eyes of 8 patients were included. Intraocular pressure (IOP) dropped from 30 +/- 2.6 mmHg pre-operatively to 22.4 +/- 2.3 mmHg one month after the first Xen implant (mean difference: -7.6 mmHg [95% confidence interval: -9.4, -5.9 mmHg], p = 0.0092). A second Xen was then implanted to achieve the target IOP. The procedure showed no significant intraoperative or postoperative complications. The IOP dropped to 16.1 +/- 2.7 mmHg six months following this second implant (mean difference: -6.3 mmHg [95% confidence interval: -7.2, -5.3 mmHg], p = 0.0183); however, 3 patients needed medical therapy to further reduce the IOP towards the target value. ConclusionSequential implantation of two Xen 45 Gel Stents using an ab externo approach with closed conjunctiva appears a promising procedure that showed a favorable safety and efficacy profile in this small case series. This pilot data might pave the way for further studies to evaluate the safety and efficacy of the procedure.
引用
收藏
页数:7
相关论文
共 27 条
[1]   Results of fluorouracil-augmented Xen45 implantation in primary open-angle and pseudoexfoliation glaucoma [J].
Baser, Esin Fatma ;
Seymenoglu, Recep Goktug .
INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (03) :945-955
[2]   Outcomes of Deep Sclerectomy following Failed XEN Gel Stent Implantation in Open-Angle Glaucoma: A Prospective Study [J].
Bravetti, Giorgio Enrico ;
Gillmann, Kevin ;
Rao, Harsha L. ;
Mermoud, Andre ;
Mansouri, Kaweh .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (16)
[3]   Theoretic scientific rationale of double XEN 45 Gel Stent implant in severe glaucomatous ocular hypertension [J].
De Gregorio, Alessandra ;
Montali, Margherita ;
Stevan, Giulia ;
Pedrotti, Emilio ;
Morselli, Simonetta .
INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (05) :1629-1638
[4]   Single versus Double Preserflo MicroShunt Implantation in Glaucoma Patients: A Retrospective Cohort Study [J].
Dervos, Thomas ;
Gugleta, Konstantin ;
Scholl, Hendrik P. N. ;
Gatzioufas, Zisis ;
Enz, Tim J. .
OPHTHALMIC RESEARCH, 2023, 66 (01) :1362-1375
[5]  
Dinno A., 2017, CRAN Repos, V10, P1
[6]   XEN® Gel Stent: A Comprehensive Review on Its Use as a Treatment Option for Refractory Glaucoma [J].
Fea, Antonio M. ;
Durr, Georges M. ;
Marolo, Paola ;
Malinverni, Lorenza ;
Economou, Mario A. ;
Ahmed, Ike .
CLINICAL OPHTHALMOLOGY, 2020, 14 :1805-1832
[7]   Comparison of Clinical Outcomes Following Gel Stent Implantation via Ab-Externo and Ab-Interno Approaches in Patients with Refractory Glaucoma [J].
Gallardo, Mark J. ;
Vincent, Logan R. ;
Porter, Matthew .
CLINICAL OPHTHALMOLOGY, 2022, 16 :2187-2197
[8]   Trabeculectomy Following Failed Ab Interno Gelatin Microstent: Case Series [J].
Gizzi, Corrado ;
Mohamed-Noriega, Jibran ;
Elkarmouty, Ahmed ;
Scott, Andrew .
JOURNAL OF GLAUCOMA, 2018, 27 (10) :E168-E173
[9]  
Grehn, 2009, GUIDELINES DESIGN RE
[10]   Performance and Safety of a New Ab Intern Gelatin Stent in Refractory Glaucoma at 12 Months [J].
Grover, Davinder S. ;
Flynn, William J. ;
Bashford, Kent P. ;
Lewis, Richard A. ;
Duh, Yi-Jing ;
Nangia, Rupali S. ;
Niksch, Barbara .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 183 :25-36