Preliminary protocol for measuring the reproducibility and accuracy of flow values on digital PET/CT systems in [15O]H2O myocardial perfusion imaging using a flow phantom

被引:0
作者
Siekkinen, Reetta [1 ,2 ,3 ,4 ,5 ]
Partanen, Heidi [2 ,3 ]
Kukola, Linda [2 ,3 ,7 ]
Tolvanen, Tuula [2 ,3 ,4 ]
Fenwick, Andrew [6 ]
Smith, Nadia A. S. [6 ]
Teras, Mika [2 ,4 ,5 ,8 ]
Saraste, Antti [2 ,3 ,5 ,9 ]
Teuho, Jarmo [1 ,2 ,3 ,5 ]
机构
[1] Univ Turku, Turku PET Ctr, Turku, Finland
[2] Turku Univ Hosp, Turku PET Ctr, Turku, Finland
[3] Wellbeing Serv Cty Southwest Finland, Turku, Finland
[4] Turku Univ Hosp, Dept Med Phys, Turku, Finland
[5] Univ Turku, Turku, Finland
[6] Natl Phys Lab, Teddington, England
[7] Univ Turku, Dept Phys & Astron, Turku, Finland
[8] Univ Turku, Inst Biomed, Turku, Finland
[9] Turku Univ Hosp, Heart Ctr, Turku, Finland
关键词
PET/CT; Myocardial perfusion imaging; Flow phantom; Test-retest reproducibility; Technical factors; Radiowater; BLOOD-FLOW; QUANTIFICATION; REPEATABILITY; RESERVE;
D O I
10.1186/s40658-024-00654-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Several factors may decrease the accuracy of quantitative PET myocardial perfusion imaging (MPI). It is therefore essential to ensure that myocardial blood flow (MBF) values are reproducible and accurate, and to design systematic protocols to achieve this. Until now, no systematic phantom protocols have been available to assess the technical factors affecting measurement accuracy and reproducibility in MPI. Materials and methods We implemented a standard measurement protocol, which applies a flow phantom in order to compare image-derived flow values with respect to a ground truth flow value with [O-15]H2O MPI performed on both a Discovery MI (DMI-20, GE Healthcare) and a Biograph Vision 600 (Vision-600, Siemens Healthineers) system. Both systems have automatic [O-15]H2O radio water generators (Hidex Oy) individually installed, allowing us to also study the differences occurring due to two different bolus delivery systems. To investigate the technical factors contributing to the modelled flow values, we extracted the [O-15]H2O bolus profiles, the flow values from the kinetic modeling (Qin and Qout), and finally calculated their differences between test-retest measurements on both systems. Results The measurements performed on the DMI-20 system produced Qin and Qout values corresponging to each other as well as to the reference flow value across all test-retest measurements. The repeatability differences on DMI-20 were 2.1% +/- 2.6% and 3.3% +/- 4.1% for Qin and Qout, respectively. On Vision-600 they were 10% +/- 8.4% and 11% +/- 10% for Qin and Qout, respectively. The measurements performed on the Vision-600 system showed more variation between Qin and Qout values across test-retest measurements and exceeded 15% difference in 7/24 of the measurements. Conclusions A preliminary protocol for measuring the accuracy and reproducibility of flow values in [O-15]H2O MPI between digital PET/CT systems was assessed. The test-retest reproducibility falls below 15% in majority of the measurements conducted between two individual injector systems and two digital PET/CT systems. This study highlights the importance of implementing a standardized bolus injection and delivery protocol and importance of assessing technical factors affecting flow value reproducibility, which should be carefully investigated in a multi-center setting.
引用
收藏
页数:17
相关论文
共 23 条
[1]   EANM/EARL harmonization strategies in PET quantification: from daily practice to multicentre oncological studies [J].
Aide, Nicolas ;
Lasnon, Charline ;
Veit-Haibach, Patrick ;
Sera, Terez ;
Sattler, Bernhard ;
Boellaard, Ronald .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 :S17-S31
[2]  
Akamatsu G, 2023, Ann Nucl Med.
[3]   Standards for PET Image Acquisition and Quantitative Data Analysis [J].
Boellaard, Ronald .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 :11S-20S
[4]   Test-retest repeatability and software reproducibility of myocardial flow measurements using rest/adenosine stress Rubidium-82 PET/CT with and without motion correction in healthy young volunteers [J].
Byrne, Christina ;
Kjaer, Andreas ;
Olsen, Naja Enevold ;
Forman, Julie Lyng ;
Hasbak, Philip .
JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) :2860-2871
[5]   More evidence for adequate test-retest repeatability of myocardial blood flow quantification with 82Rb PET/CT [J].
deKemp, Robert A. ;
Celiker Guler, Emel ;
Ruddy, Terrence D. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) :2872-2875
[6]   82Rb PET imaging of myocardial blood flow-have we achieved the 4 "R"s to support routine use? [J].
deKemp, Robert A. ;
Klein, Ran ;
Beanlands, Rob S. B. .
EJNMMI RESEARCH, 2016, 6
[7]   Impact of PET reconstruction protocols on quantification of lesions that fulfil the PERCIST lesion inclusion criteria [J].
Devriese, Joke ;
Beels, Laurence ;
Maes, Alex ;
Van de Wiele, Christophe ;
Pottel, Hans .
EJNMMI PHYSICS, 2018, 5
[8]   Use of a Qualification Phantom for PET Brain Imaging in a Multicenter Consortium: A Collaboration Between the Pediatric Brain Tumor Consortium and the SNMMI Clinical Trials Network [J].
Fahey, Frederic ;
Christiana, Paul ;
Zukotynski, Katherine ;
Sexton-Stallone, Briana ;
Kiss, Christina ;
Clarke, Bonnie ;
Onar-Thomas, Arzu ;
Poussaint, Tina Young .
JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (05) :677-682
[9]   Validation of a Multimodality Flow Phantom and Its Application for Assessment of Dynamic SPECT and PET Technologies [J].
Gabrani-Juma, Hanif ;
Clarkin, Owen J. ;
Pourmoghaddas, Amir ;
Driscoll, Brandon ;
Wells, R. Glenn ;
deKemp, Robert A. ;
Klein, Ran .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (01) :132-141
[10]   MEASUREMENT OF ABSOLUTE MYOCARDIAL BLOOD-FLOW WITH (H2O)-O-15 AND DYNAMIC POSITRON-EMISSION TOMOGRAPHY - STRATEGY FOR QUANTIFICATION IN RELATION TO THE PARTIAL-VOLUME EFFECT [J].
IIDA, H ;
KANNO, I ;
TAKAHASHI, A ;
MIURA, S ;
MURAKAMI, M ;
TAKAHASHI, K ;
ONO, Y ;
SHISHIDO, F ;
INUGAMI, A ;
TOMURA, N ;
HIGANO, S ;
FUJITA, H ;
SASAKI, H ;
NAKAMICHI, H ;
MIZUSAWA, S ;
KONDO, Y ;
UEMURA, K .
CIRCULATION, 1988, 78 (01) :104-115