Real-World Continuous Glucose Monitoring Data from a Population with Type 1 Diabetes in South Korea: Nationwide Single-System Analysis

被引:0
作者
Kim, Ji Yoon [1 ]
Jin, Sang-Man [1 ]
Andrade, Sarah B. [2 ]
Chen, Boyang [2 ]
Kim, Jae Hyeon [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Div Endocrinol & Metab,Dept Med, 81 Irwon ro, Seoul 06351, South Korea
[2] Dexcom Inc, San Diego, CA USA
关键词
Real-time continuous glucose monitoring; Time in range; Type; 1; diabetes; Glycemic control; Global health; TIME;
D O I
10.1089/dia.2023.0513
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We used continuous glucose monitoring (CGM) data to investigate glycemic outcomes in a real-world population with type 1 diabetes (T1D) from South Korea, where the widespread use of CGM and the nationwide education program began almost simultaneously. Methods: Data from Dexcom G6 users with T1D in South Korea were collected between January 2019 and January 2023. Users were included if they provided at least 90 days of glucose data and used CGM at least 70% of the days in the investigational period. The relationship between CGM utilization and glycemic metrics, including the percentage of time in range (TIR), time below range (TBR), and time above range (TAR), was assessed. The study was approved by the Institutional Review Board of Samsung Medical Center (SMC 2023-05-030). Results: A total of 2288 users were included. Mean age was 41.5 years (57% female), with average uploads of 428 days. Mean TIR was 62.4% +/- 18.5%, mean TBR <70 mg/dL was 2.6% +/- 2.8%, mean TAR >180 mg/dL was 35.0% +/- 19.3%, mean glucose was 168.1 +/- 35.8 mg/dL, mean glucose management indicator was 7.2% +/- 0.9%, and mean coefficient of variation was 36.7% +/- 6.0%. Users with higher CGM utilization had higher TIR (67.8% vs. 52.7%), and lower TBR <70 mg/dL (2.3% vs. 4.7%) and TAR >180 mg/dL (30.0% vs. 42.6%) than those with low CGM utilization (P < 0.001 for all). Users whose data were shared with others had higher TIR than those who did not (63.3% vs. 60.8%, P = 0.001). Conclusions: In this South Korean population, higher CGM utilization was associated with a favorably higher mean TIR, which was close to the internationally recommended target. Using its remote data-sharing feature showed beneficial impact on TIR.
引用
收藏
页码:394 / 402
页数:9
相关论文
共 31 条
[1]   G6 continuous glucose monitoring system feature use and its associations with glycaemia in Europe [J].
Acciaroli, Giada ;
Parkin, Christopher G. ;
Thomas, Roy ;
Layne, Jennifer ;
Norman, Gregory J. ;
Leone, Keri .
DIABETIC MEDICINE, 2023, 40 (06)
[2]   Longitudinal analysis of users transitioning from the Dexcom G5 to the G6 RT-CGM system in Germany, Sweden and the United Kingdom (2018-2020) [J].
Acciaroli, Giada ;
van der Linden, Joost ;
Chao, Christy ;
Walker, Tomas C. ;
Oliver, Nick .
DIABETIC MEDICINE, 2023, 40 (02)
[3]   Real-World Evidence and Glycemic Improvement Using Dexcom G6 Features [J].
Akturk, Halis Kaan ;
Dowd, Robert ;
Shankar, Kaushik ;
Derdzinski, Mark .
DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 :S21-S26
[4]  
[Anonymous], 2015, IDF DIABETES ATLAS, V7th
[5]   Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range [J].
Battelino, Tadej ;
Danne, Thomas ;
Bergenstal, Richard M. ;
Amiel, Stephanie A. ;
Beck, Roy ;
Biester, Torben ;
Bosi, Emanuele ;
Buckingham, Bruce A. ;
Cefalu, William T. ;
Close, Kelly L. ;
Cobelli, Claudio ;
Dassau, Eyal ;
DeVries, J. Hans ;
Donaghue, Kim C. ;
Dovc, Klemen ;
Doyle, Francis J. ;
Garg, Satish ;
Grunberger, George ;
Heller, Simon ;
Heinemann, Lutz ;
Hirsch, Irl B. ;
Hovorka, Roman ;
Jia, Weiping ;
Kordonouri, Olga ;
Kovatchev, Boris ;
Kowalski, Aaron ;
Laffel, Lori ;
Levine, Brian ;
Mayorov, Alexander ;
Mathieu, Chantal ;
Murphy, Helen R. ;
Nimri, Revital ;
Norgaard, Kirsten ;
Parkin, Christopher G. ;
Renard, Eric ;
Rodbard, David ;
Saboo, Banshi ;
Schatz, Desmond ;
Stoner, Keaton ;
Urakami, Tatsuiko ;
Weinzimer, Stuart A. ;
Phillip, Moshe .
DIABETES CARE, 2019, 42 (08) :1593-1603
[6]   The Association of Time in Range and Diabetic Complications: The Evidence Is Strong [J].
Beck, Roy W. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 (06) :375-377
[7]   Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections The DIAMOND Randomized Clinical Trial [J].
Beck, Roy W. ;
Riddlesworth, Tonya ;
Ruedy, Katrina ;
Ahmann, Andrew ;
Bergenstal, Richard ;
Haller, Stacie ;
Kollman, Craig ;
Kruger, Davida ;
McGill, Janet B. ;
Polonsky, William ;
Toschi, Elena ;
Wolpert, Howard ;
Price, David .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (04) :371-378
[8]   Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Tamborlane, William V. ;
Ahmann, Andrew ;
Buse, John B. ;
Dailey, George ;
Davis, Stephen N. ;
Joyce, Carol ;
Peoples, Tim ;
Perkins, Bruce A. ;
Welsh, John B. ;
Willi, Steven M. ;
Wood, Michael A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (04) :311-320
[9]   Real-world outcomes of continuous glucose monitoring in adults with diabetes mellitus attending an Irish tertiary hospital [J].
Courtney, Aoife ;
Smith, Diarmuid ;
Forde, Hannah .
IRISH JOURNAL OF MEDICAL SCIENCE, 2023, 192 (06) :2763-2768
[10]   Glycemic Outcomes and Feature Set Engagement Among Real-Time Continuous Glucose Monitoring Users With Type 1 or Non-Insulin-Treated Type 2 Diabetes: Retrospective Analysis of Real-World Data [J].
Dowd, Robert ;
Jepson, Lauren H. ;
Green, Courtney R. ;
Norman, Gregory J. ;
Thomas, Roy ;
Leone, Keri .
JMIR DIABETES, 2023, 8