Effect of needles distance of arteriovenous fistula cannulation on hemodialysis adequacy based on KT/V: a randomized controlled trial

被引:1
作者
Karkhah, Samad [1 ]
Pourshaikhian, Majid [2 ]
Maroufizadeh, Saman [3 ]
Ghorbani Vajargah, Pooyan [1 ]
Aghajanzadeh, Pegah [4 ]
Osuji, Joseph [5 ]
Moghadamnia, Mohammad Taghi [1 ,2 ]
机构
[1] Guilan Univ Med Sci, Sch Nursing & Midwifery, Dept Med Surg Nursing, Rasht, Iran
[2] Guilan Univ Med Sci, Sch Nursing & Midwifery, Dept Prehosp Emergency Med, Rasht, Iran
[3] Guilan Univ Med Sci, Sch Hlth, Dept Biostat, Rasht, Iran
[4] Guilan Univ Med Sci, Razi Hosp, Urol Res Ctr, Sch Med, Rasht, Iran
[5] Mt Royal Univ, Fac Hlth Community & Educ, Sch Nursing & Midwifery, Calgary, AB, Canada
关键词
arteriovenous fistula; cannulation; dialysis adequacy; haemodialysis; vascular access;
D O I
10.1097/MS9.0000000000001966
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study aims to assess the effect of needle distance of arteriovenous fistula (AVF) cannulation on haemodialysis adequacy based on KT/V. Materials and methods: This study was a parallel-group, randomized controlled trial. Patients who met the inclusion criteria were divided into two groups with 3 and 6 cm needle distances using block randomization. Data acquisition transpired through a comprehensive checklist encompassing demographic variables such as age and sex, alongside clinical metrics comprising actual weight, dry weight, average dialysis duration, fistula longevity, and KT/V rate. Results: A total of 42 haemodialysis patients were enroled in this investigation, with 21 allocated to the 3 cm needle distance group and another 21 to the 6 cm needle distance group. The mean post-haemodialysis KT/V values for the 3 cm and 6 cm needle distance groups were 1.25 (SD=0.25) and 1.42 (SD=0.24), respectively, demonstrating a statistically significant difference (P<0.001). While there was no significant difference in the average pre-haemodialysis and post-haemodialysis KT/V values within the 3 cm needle distance group (t=1.93, P=0.068), the corresponding values for the 6 cm needle distance group exhibited a notable discrepancy (t=9.66, P<0.001). Conclusion: In general, a needle distance of 6 cm between arteriovenous points yielded superior enhancements in dialysis adequacy compared to a 3 cm needle distance following haemodialysis. Consequently, health administrators and policymakers may consider instituting efficacious interventions to scrutinize the care and therapeutic protocols for haemodialysis patients, involving the development of policies and applications.
引用
收藏
页码:2739 / 2744
页数:6
相关论文
共 20 条
[1]   Tract dilation to salvage failing buttonholes in arteriovenous dialysis fistulae [J].
Barzel, Eyal ;
Larkin, John W. ;
Marcus, Allen ;
Reviriego-Mendoza, Marta M. ;
Usvyat, Len A. ;
Sor, Murat ;
Maddux, Franklin W. .
JOURNAL OF VASCULAR ACCESS, 2019, 20 (03) :290-300
[2]  
Cheng A, 2016, CLIN SIMUL NURS, V12, pA3, DOI [10.1016/j.ecns.2016.04.008, 10.1186/s41077-016-0025-y]
[3]  
Daugirdas J T, 1995, Adv Ren Replace Ther, V2, P295
[4]   Arteriovenous Fistula Puncture: An Essential Factor for Hemodialysis Efficiency [J].
Dias, Taisa Silva ;
Neto, Miguel Moyses ;
Cardeal da Costa, Jose Abrao .
RENAL FAILURE, 2008, 30 (09) :870-876
[5]   Impact of arteriovenous fistula cannulation on the quality of dialysis [J].
Elias, Michelle ;
Nnang-Obada, Erika ;
Charpentier, Bernard ;
Durrbach, Antoine ;
Beaudreuil, Severine .
HEMODIALYSIS INTERNATIONAL, 2018, 22 (01) :45-49
[6]   Factors affecting arteriovenous fistula dysfunction: A narrative review [J].
Gameiro, Joana ;
Ibeas, Jose .
JOURNAL OF VASCULAR ACCESS, 2020, 21 (02) :134-147
[7]   Needle Direction and Distance of Arteriovenous Fistula Cannulation in Hemodialysis Adequacy; a Systematic Review and Meta-Analysis [J].
Karkhah, Samad ;
Pourshaikhian, Majid ;
Vajargah, Pooyan Ghorbani ;
Mahdiabadi, Morteza Zaboli ;
Mollaei, Amirabbas ;
Maroufizadeh, Saman ;
Hosseini, Seyed Javad ;
Osuji, Joseph ;
Moghadamnia, Mohammad Taghi .
ARCHIVES OF ACADEMIC EMERGENCY MEDICINE, 2023, 11 (01)
[8]   What is the best between needles distance and direction for arteriovenous fistula cannulation in hemodialysis patients? An important yet challenging issue [J].
Karkhah, Samad ;
Ghazanfari, Mohammad Javad ;
Emami Zeydi, Amir .
JOURNAL OF VASCULAR ACCESS, 2022, 23 (03) :490-491
[9]   Coronal mode ultrasound guided hemodialysis cannulation: A pilot randomized comparison with standard cannulation technique [J].
Kumbar, Lalathaksha ;
Soi, Vivek ;
Adams, Elizabeth ;
Brown Deacon, Cheryl ;
Zidan, Mohamed ;
Yee, Jerry .
HEMODIALYSIS INTERNATIONAL, 2018, 22 (01) :23-30
[10]  
Laing B., 2019, Bioengineering, P2314