Aerodynamic mitigation of wind loads on a large-span cantilevered roof: A combined wind tunnel and CFD analysis

被引:1
作者
Chen, Fubin [1 ]
Wang, Weijia [1 ]
Yang, Danqing [1 ]
Shu, Zhenru [2 ]
机构
[1] Changsha Univ Sci & Technol, Sch Civil Engn, Changsha 410114, Peoples R China
[2] Cent South Univ, Sch Civil Engn, Changsha 410075, Peoples R China
基金
中国国家自然科学基金;
关键词
aerodynamic mitigation; large-span cantilevered roof; numerical simulation; wind pressure distribution; wind tunnel test; LOW-RISE BUILDINGS; PREDICTION; PRESSURES;
D O I
10.12989/was.2024.38.3.203
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Large-span cantilevered roof represents a unique type of structure that is vulnerable to wind loads. Inspired by the need to maximumly reducing the rooftop wind loads, this study examined the feasibility of positioning vented slots on the leading edge, and the effectiveness of such aerodynamic mitigation measures are assessed via both physical and numerical simulations. The reliability of numerical simulation was evaluated via comparisons with the wind tunnel tests. The results indicated that, the variation of venting hole arrangement can cause significant change in the rooftop wind load characteristics. For the cases involved in this study, the maximum reduction of mean and peak wind suction coefficients are found to be 9% and 8% as compared to the original circular slot without venting holes. In addition, the effect of slot shape is also evident. It was shown that the triangular shaped slot tends to increase the wind suction near the leading edge, whereas the hexagonal and octagonal shaped slots are found to decrease the wind suction. In particular, with the installation of octagonal shaped slot, the maximum reduction of wind suction coefficients near the leading edge reaches up to 31% as compared to the circular shaped slot, while the maximum reduction of mean wind suction coefficients is about 30%.
引用
收藏
页码:203 / 214
页数:12
相关论文
共 38 条
[1]   Experimental investigation of wind impact on low-rise elevated residences [J].
Abdelfatah, Nourhan ;
Elawady, Amal ;
Irwin, Peter ;
Chowdhury, Arindam Gan .
ENGINEERING STRUCTURES, 2022, 257
[2]   Aerodynamic mitigation of wind-induced uplift forces on low-rise buildings: A comparative study [J].
Aly, Aly-Mousaad ;
Bresowar, Joseph .
JOURNAL OF BUILDING ENGINEERING, 2016, 5 :267-276
[3]  
[Anonymous], 2012, GB 50009-2012 Load Code for the Design of Building Structures
[4]  
[Anonymous], 1990, Static structures. Building Research Establishment Report
[5]   MODEL FULL-SCALE PRESSURE MEASUREMENTS ON A GRANDSTAND [J].
APPERLEY, LW ;
PITSIS, NG .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1986, 23 (1-3) :99-111
[6]   WIND LOADS ON CANTILEVERED ROOF STRUCTURES [J].
BARNARD, RH .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1981, 8 (1-2) :21-30
[7]   Full-scale validation of vortex suppression techniques for mitigation of roof uplift [J].
Blessing, Collette ;
Chowdhury, Arindam Gan ;
Lin, Jason ;
Huang, Peng .
ENGINEERING STRUCTURES, 2009, 31 (12) :2936-2946
[8]   Experimental investigation of wind pressure characteristics and aerodynamic optimization of a large-span cantilevered roof [J].
Chen, Fubin ;
Wang, Weijia ;
Zhou, Jinfang ;
Shu, Zhenru ;
Li, Qiusheng .
STRUCTURES, 2021, 34 :303-313
[9]  
Chen J., 2022, Quarter. J. Mech., V43, P372
[10]  
Cochran L.S., 1997, Architectural Science Review, V40, P79, DOI DOI 10.1080/00038628.1997.9697388