Cardiac Magnetic Resonance and Cardiac Implantable Electronic Devices: Are They Truly Still "Enemies"?

被引:0
|
作者
Fogante, Marco [1 ]
Volpato, Giovanni [2 ]
Pirani, Paolo Esposto [1 ]
Cela, Fatjon [1 ]
Compagnucci, Paolo [2 ]
Valeri, Yari [2 ]
Selimi, Adelina [2 ]
Alfieri, Michele [2 ]
Brugiatelli, Leonardo [2 ]
Belleggia, Sara [2 ]
Coraducci, Francesca [2 ]
Argalia, Giulio [1 ]
Casella, Michela [2 ,3 ]
Dello Russo, Antonio [2 ,4 ]
Schicchi, Nicolo [5 ]
机构
[1] Univ Hosp Marche, Dept Radiol Sci, Maternal Child Senol Cardiol Radiol & Outpatient U, I-60126 Ancona, Italy
[2] Univ Hosp Azienda Osped Univ Marche, Cardiol & Arrhythmol Clin, I-60126 Ancona, Italy
[3] Marche Polytech Univ, Dept Clin Special & Dent Sci, I-60121 Ancona, Italy
[4] Marche Polytech Univ, Dept Biomed Sci & Publ Hlth, I-60121 Ancona, Italy
[5] Univ Hosp Marche, Dept Radiol Sci, Cardiovasc Radiol Diagnost, Ancona, Italy
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 04期
关键词
cardiac magnetic resonance; cardiac implantable electronic device; pacemaker; implantable cardiac defibrillator; loop recorder; safety; artifacts; CARDIOVERTER-DEFIBRILLATORS; SAFETY; RISK; MRI; CT; ELECTROPHYSIOLOGY; PACEMAKERS; SOCIETY; SYNCOPE; PATIENT;
D O I
10.3390/medicina60040522
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices With Abandoned Leads
    Schaller, Robert D.
    Brunker, Tamara
    Riley, Michael P.
    Marchlinski, Francis E.
    Nazarian, Saman
    Litt, Harold
    JAMA CARDIOLOGY, 2021, 6 (05) : 549 - 556
  • [22] Magnetic resonance imaging in patients with cardiac implantable electronic devices: A prospective study
    Navarro-Valverde, Cristina
    Ramos-Maqueda, Javier
    Jose Romero-Reyes, M.
    Esteve-Ruiz, Irene
    Garcia-Medina, Dolores
    Pavon-Jimenez, Ricardo
    Rodriguez-Gomez, Cristobal
    Leal-Del-Ojo, Juan
    Cayuela, Aurelio
    Molano-Casimiro, Francisco J.
    MAGNETIC RESONANCE IMAGING, 2022, 91 : 9 - 15
  • [23] MAGNETIC RESONANCE AND CARDIAC IMPLANTABLE DEVICES: A SAFE COMBINATION
    Saporito, D.
    Fabbri, F.
    Spighi, L.
    Trevisi, N.
    Ottani, F.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2024, 26 : ii18 - ii18
  • [24] Magnetic Resonance Imaging in Patients With Implantable Cardiac Devices
    Sierra, Mark
    Machado, Christian
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2008, 9 (04) : 232 - 238
  • [25] Cardiac Implantable Electronic Devices
    Al-Khatib, Sana M.
    NEW ENGLAND JOURNAL OF MEDICINE, 2024, 390 (05): : 442 - 454
  • [26] "Power-on resets" in cardiac implantable electronic devices during magnetic resonance imaging
    Higgins, John V.
    Sheldon, Seth H.
    Watson, Robert E., Jr.
    Dalzell, Connie
    Acker, Nancy
    Cha, Yong-Mei
    Asirvatham, Samuel J.
    Kapa, Suraj
    Felmlee, Joel P.
    Friedman, Paul A.
    HEART RHYTHM, 2015, 12 (03) : 540 - 544
  • [27] Clinical Performance of Magnetic Resonance Imaging Conditional and Nonconditional Cardiac Implantable Electronic Devices
    Shah, Anand D.
    Patel, Adarsh U.
    Knezevic, Andrea
    Hoskins, Michael H.
    Hirsh, David S.
    Merchant, Faisal M.
    El Chami, Mikhael F.
    Delurgio, David B.
    Patel, Anshul M.
    Leon, Angel R.
    Langberg, Jonathan J.
    Lloyd, Michael S.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (05): : 467 - 475
  • [28] Synopsis of JBS recommendations for magnetic resonance imaging in patients with cardiac implantable electronic devices
    Zghaib, Tarek
    Nazarian, Saman
    HEART, 2024, 110 (04) : 225 - 227
  • [29] Infections of cardiac implantable electronic devices: still a cause of high mortality
    Goette, Andreas
    Sommer, Philipp
    EUROPACE, 2021, 23 : 1 - 2
  • [30] Cardiac MRI for Patients With Cardiac Implantable Electronic Devices
    Stojanovska, Jadranka
    Runge, Mason
    Mahani, Maryam Ghadimi
    Cronin, Paul P.
    Sayyouh, Mohamed
    Bogun, Frank
    Ibrahim, El-Sayed H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 374 - 381