共 15 条
Experimental studies on the heat transfer characteristics of helium-based cryogenic oscillating heat pipes
被引:1
作者:
Yi, Huo
[1
,2
]
Changcheng, Ma
[1
]
Jun, Zhang
[3
]
Rui, Huang
[3
]
Rui, Ge
[1
]
机构:
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Hefei Univ Technol, Hefei, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Heat transfer characteristics;
Cryogenic oscillating heat pipe;
Oscillation intensity;
THERMAL PERFORMANCE;
D O I:
10.1007/s41605-024-00464-x
中图分类号:
TL [原子能技术];
O571 [原子核物理学];
学科分类号:
0827 ;
082701 ;
摘要:
PurposeCopper is a cooling transfer material used in cryogenic superconducting systems. The effective thermal conductivity (ETC) of copper in the 4K region is only about 400 W/(m K). Its heat transfer performance is poor, there are some shortcomings such as large temperature difference, temperature fluctuation lag, cryogenic system layout limited. The ETC value of helium-based cryogenic oscillating heat pipes (COHP) in the 4K region is much higher than that of copper. However, the choice of heating power interval is very important, and the heating power will affect the oscillation characteristics of COHP.MethodsIn this study, a helium-based COHP heat transfer performance test platform was built in the 4K region, and the effects of heating power and liquid filling rate on oscillation conditions and ETC were studied. The heating power ranges from 0.1 to 0.5 W, and the liquid filling rate ranges from 20% to 87%.Results and conclusionThe heating power interval suitable for oscillation behavior is given quantitatively. The intrinsic correlation between ETC and amplitude is further discussed. The results are of great significance for improving the performance of cryogenic superconducting systems.
引用
收藏
页码:1 / 7
页数:7
相关论文