Research on target organ motion tracking method based on the fusion of inertial navigation and electromagnetic navigation

被引:0
|
作者
Wang K. [1 ,2 ]
Zhang Y. [1 ,2 ]
Liu Y. [3 ]
机构
[1] Key Laboratory of Ministry of Education of Advanced Manufacturing and Intelligent Technology, Harbin University of Science and Technology, Harbin
[2] Intelligent Machine Institute, Harbin University of Science and Technology, Harbin
[3] T Stone Robotics Institute, Shenzhen Research Institute, The Chinese University of Hong Kong, Shenzhen
来源
Zhang, Yongde (zhangyd@hrbust.edu.cn) | 1600年 / Science Press卷 / 41期
关键词
Electromagnetic navigation; Fusion algorithm; Inertial navigation; Intraoperative navigation; Target organ tracking;
D O I
10.19650/j.cnki.cjsi.J2006779
中图分类号
学科分类号
摘要
The intraoperative movement of target organs is currently a key and difficult problem that restricts the diagnosis and treatment of clinical surgery, especially radiotherapy. The unexpected posture changes can cause the deviation of the target area during operation, thereby affecting the treatment effect and even causing serious complications. Therefore, it is necessary to track the movement of target organs in real time and accurately improve the effect and safety of surgical treatment. This paper proposes a target organ movement fusion tracking method based on inertial navigation and electromagnetic navigation fusion, which can directly measure the movement of the target organ under non-invasive or minimally invasive conditions using the human natural cavity. Based on the proposed interference state discriminating method of the fusion tracking system, the extended Kalman filter is used to fuse the inertial measurement unit and the electromagnetic positioning information and realize the fusion tracking of the target organ movement under different interference conditions, which effectively improves the real-time performance and robustness of intraoperative organ tracking. At the same time, based on a 0.002 rad/s gyroscope, a 5 mg accelerometer and a 6-DOF electromagnetic positioning system, a catheter-type target organ fusion tracker was developed, and dynamic and static verification experiments were carried out in a simulated intraoperative electromagnetic interference environment. Through experiments, the maximum tracking errors of displacement and attitude are 2.51 mm and 0.127 rad, respectively under severe electromagnetic disturbance. Under non-electromagnetic interference condition, the maximum tracking errors of displacement and attitude are 0.93 mm and 0.011 rad, respectively. The results prove that the target organ tracking method based on the fusion of inertial navigation and electromagnetic navigation is feasible, and can realize the tracking and measurement of the target organ movement posture within the clinical permission error range. © 2020, Science Press. All right reserved.
引用
收藏
页码:177 / 187
页数:10
相关论文
共 21 条
  • [1] KOK E N, EPPENGA R, KUHLMANN K F, Et al., Accurate surgical navigation with real-time tumor tracking in cancer surgery, NPJ Precision Oncology, 4, 1, pp. 1-7, (2020)
  • [2] LIANG Z, YANG J, LIU H, Et al., Real-time tumor motion monitoring and PTV margin determination in lung SBRT treatment, Acta Oncologica, 58, 12, pp. 1786-1789, (2019)
  • [3] TONG Y, GONG G, CHEN J, Et al., The heterogeneous CTV-PTV margins should be given for different parts of tumors during tomotherapy, Oncotarget, 8, 51, pp. 89086-89094, (2017)
  • [4] ZHANG Y D, ZHANG W X, LIANG Y, Et al., Research on mechanism and strategy of high accuracy puncture of prostate, Chinese Journal of Scientific Instrument, 38, 6, pp. 1405-1412, (2017)
  • [5] GORGISYAN J, LOMAX A J, AF ROSENSCHOLD P M, Et al., The dosimetric effect of residual breath-hold motion in pencil beam scanned proton therapy-An experimental study, Radiotherapy and Oncology, 134, pp. 135-142, (2019)
  • [6] ROMAGUERA L V, OLOFSSON N, PLANTEFEVE R, Et al., Automatic self-gated 4D-MRI construction from free-breathing 2D acquisitions applied on liver images, International Journal of Computer Assisted Radiology and Surgery, 14, 6, pp. 933-944, (2019)
  • [7] GINN J S, RUAN D, LOW D A, Et al., An image regression motion prediction technique for MRI-guided radiotherapy evaluated in single-plane cine imaging, Medical Physics, 47, 2, pp. 404-413, (2020)
  • [8] LINGAIAH R, ALI M A, KULSUM U, Et al., GTV volume estimation using different mode of computer tomography for lung tumors in stereotactic body radiation therapy, Polish Journal of Medical Physics and Engineering, 25, 1, pp. 29-34, (2019)
  • [9] ZELENTY W D, RENEHAN J R, FERGUSON J, Et al., Intraoperative navigation: Current applications and future directions, Seminars in Spine Surgery, (2020)
  • [10] CHENG C, FANG H Y, WEN C T, Et al., Real-time image-guided electromagnetic navigation bronchoscopy dual-marker technique to localize deep pulmonary nodules in a hybrid operating room, European Journal of Cardio-Thoracic Surgery, pp. 1-3, (2020)