Comparison of Flow Reduction Efficacy of Nominal and Oversized Flow Diverters Using a Novel Measurement-assisted in Silico Method

被引:0
|
作者
Csippa, Benjamin [1 ]
Sandor, Levente [1 ]
Zavodszky, Gabor [1 ,3 ]
Szikora, Istvan [2 ]
Paal, Gyorgy [1 ]
机构
[1] Budapest Univ Technol & Econ, Fac Mech Engn, Dept Hydrodynam Syst, Muegyetem Rkp 1-3, H-1111 Budapest, Hungary
[2] Natl Inst Mental Hlth Neurol & Neurosurg, Dept Neurointervent, Budapest, Hungary
[3] Univ Amsterdam, Informat Inst, Fac Sci, Computat Sci Lab, Amsterdam, Netherlands
基金
欧盟地平线“2020”;
关键词
Aneurysm; CFD; Hemodynamics; Stroke; Intervention; DIVERSION; ANEURYSMS; STENTS; IMPACT;
D O I
10.1007/s00062-024-01404-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose The high efficacy of flow diverters (FD) in the case of wide-neck aneurysms is well demonstrated, yet new challenges have arisen because of reported posttreatment failures and the growing number of new generation of devices. Our aim is to present a measurement-supported in silico workflow that automates the virtual deployment and subsequent hemodynamic analysis of FDs. In this work, the objective is to analyze the effects of FD deployment variability of two manufacturers on posttreatment flow reduction.Methods The virtual deployment procedure is based on detailed mechanical calibration of the flow diverters, while the flow representation is based on hydrodynamic resistance (HR) measurements. Computational fluid dynamic simulations resulted in 5 untreated and 80 virtually treated scenarios, including 2 FD designs in nominal and oversized deployment states. The simulated aneurysmal velocity reduction (AMVR) is correlated with the HR values and deployment scenarios.Results The linear HR coefficient and AMVR revealed a power-law relationship considering all 80 deployments. In nominal deployment scenarios, a significantly larger average AMVR was obtained (60.3%) for the 64-wire FDs than for 48-wire FDs (51.9%). In oversized deployments, the average AMVR was almost the same for 64-wire and 48-wire device types, 27.5% and 25.7%, respectively.Conclusion The applicability of our numerical workflow was demonstrated, also in large-scale hemodynamic investigations. The study revealed a robust power-law relationship between a HR coefficient and AMVR. Furthermore, the 64 wire configurations in nominal sizing produced a significantly higher posttreatment flow reduction, replicating the results of other in vitro studies.
引用
收藏
页码:675 / 684
页数:10
相关论文
共 26 条
  • [1] Treatment for middle cerebral artery bifurcation aneurysms: in silico comparison of the novel Contour device and conventional flow-diverters
    Lyu, Mengzhe
    Torii, Ryo
    Liang, Ce
    Peach, Thomas W.
    Bhogal, Pervinder
    Makalanda, Levansri
    Li, Qiaoqiao
    Ventikos, Yiannis
    Chen, Duanduan
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2024, 23 (04) : 1149 - 1160
  • [2] A novel method of using a control valve for measurement and control of flow
    Atmanand, MA
    Konnur, MS
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (06) : 1224 - 1226
  • [3] A novel method of using a control valve for measurement and control of flow
    Atmanand, MA
    Konnur, MS
    JOINT CONFERENCE - 1996: IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE & IMEKO TECHNICAL COMMITTEE 7, CONFERENCE PROCEEDINGS, VOLS I AND II: QUALITY MEASUREMENTS: THE INDISPENSABLE BRIDGE BETWEEN THEORY AND REALITY (NO MEASUREMENTS? NO SCIENCE!), 1996, : 813 - 816
  • [4] Reduction of Device Induced Artifacts in Novel Bioresorbable Flow Diverters Using Ultra High Resolution Photon Counting Detector CT
    Koons, E.
    Oliver, A.
    Kallmes, D.
    McCollough, C.
    Leng, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E550 - E551
  • [5] A COMPUTER-ASSISTED METHOD FOR MEASUREMENT OF PULSATILE BLOOD-FLOW USING CINE DENSITOMETRY
    BRILL, AB
    PRICE, RR
    ERICKSON, JJ
    SMITH, CW
    EFRON, U
    KEDEM, D
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 775 - 775
  • [6] A comparison of a novel flow cytometry method with a haemagglutination card technique in the measurement of blood group isoagglutinins
    Abel, Angela A.
    Turkington, Sylvia
    Stewart, Karen M.
    Steven, Raymond
    Marson, Lorna
    Turner, David M.
    TISSUE ANTIGENS, 2010, 75 (05): : 590 - 590
  • [7] A novel echocardiography method to assess upper body systemic blood flow in preterm infants and comparison with superior vena cava flow measurement
    Schena, Federico
    Iannotta, Rossella
    D'Andrea, Vito
    Francescato, Gaia
    Mayer, Alessandra
    Mancini, Giuseppina
    Prontera, Giorgia
    Mosca, Fabio
    Vento, Gianni
    EUROPEAN JOURNAL OF PEDIATRICS, 2023, 182 (04) : 1839 - 1845
  • [8] A novel echocardiography method to assess upper body systemic blood flow in preterm infants and comparison with superior vena cava flow measurement
    Federico Schena
    Rossella Iannotta
    Vito D’Andrea
    Gaia Francescato
    Alessandra Mayer
    Giuseppina Mancini
    Giorgia Prontera
    Fabio Mosca
    Gianni Vento
    European Journal of Pediatrics, 2023, 182 : 1839 - 1845
  • [9] Measurement of cerebral blood flow responses to the thigh cuff maneuver: a comparison of TCD with a novel MRI method
    Saeed, Nazia P.
    Horsfield, Mark A.
    Panerai, Ronney B.
    Mistri, Amit K.
    Robinson, Tom G.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2011, 31 (05): : 1302 - 1310