A novel premixing strategy for highly sensitive detection of nitrite on paper-based analytical devices

被引:6
|
作者
Xu, Xiaohu [1 ]
Nilghaz, Azadeh [2 ,3 ]
Wan, Xiaofang [1 ]
Liu, Shan [4 ,5 ]
Xue, Meigui [6 ]
Guo, Wan [7 ]
Tian, Junfei [1 ,5 ]
机构
[1] South China Univ Technol, Sch Light Ind & Engn, State Key Lab Pulp & Paper Engn, Guangzhou 510641, Peoples R China
[2] Deakin Univ, Inst Frontier Mat, Waurn Ponds, Vic 3216, Australia
[3] Monash Univ, Monash Inst Pharmaceut Sci, Drug Delivery Disposit & Dynam, Parkville, Vic 3052, Australia
[4] South China Univ Technol, Sch Med, Guangzhou 510006, Peoples R China
[5] Guangdong Prov Key Lab Plant Resources Biorefinery, Guangzhou 510006, Peoples R China
[6] Dongguan Polytech, Dongguan 523808, Guangdong, Peoples R China
[7] Zhejiang Kan New Mat Co Ltd, Lishui 323300, Peoples R China
基金
中国国家自然科学基金;
关键词
Nitrite detection; Premixing strategy; Rapid food safety and quality analysis; Meat samples; Paper -based analytical devices; NITRATE; SAMPLES; PERFORMANCE; BIOSENSOR; PLATFORM; SYSTEM; SENSOR;
D O I
10.1016/j.aca.2024.342417
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Nitrite has been involved in many food processing techniques and its excessive consumption is closely related to the development of different diseases. Therefore, highly sensitive detection of nitrite is significant to ensure food safety. Result: This study presents a simple and novel strategy for the highly sensitive detection of nitrite in food using paper-based analytical devices (PADs). In this proposed strategy, the nitrite present in the sample undergoes efficient diazotization when initially mixed with sulfanilamide solution before reacting with N-(1-naphthyl) ethylenediamine dihydrochloride (NED) coated on the detection region of the PAD, leading to the maximum production of colored azo compounds. Specifically, within the concentration range of 0.1 -20 mg/L, the LOD and LOQ for the nitrite assay using the premixing strategy are determined as 0.053 mg/L and 0.18 mg/L, respectively which significantly surpass the corresponding values of 0.18 mg/L (LOD) and 0.61 mg/L (LOQ) achieved with the regular Griess reagent analysis. Significance: The study highlights the critical importance of the premixing strategy in nitrite detection. Under optimized conditions, the strategy demonstrates an excellent limit of detection (LOD) and limit of quantification (LOQ) for nitrite detection in eight different meat samples. In addition to its high precision, the strategy is applicable in the field of nitrite analysis. This strategy could facilitate rapid and cost-effective nitrite analysis in real food samples, ensuring food safety and quality analysis.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Highly Sensitive Detection of Salmonella typhimurium Using a Colorimetric Paper-Based Analytical Device Coupled with Immunomagnetic Separation
    Srisa-Art, Monpichar
    Boehle, Katherine E.
    Geiss, Brian J.
    Henry, Charles S.
    ANALYTICAL CHEMISTRY, 2018, 90 (01) : 1035 - 1043
  • [42] Microfluidic Paper-Based Analytical Device for the Determination of Nitrite and Nitrate
    Jayawardane, B. Manori
    Wei, Shen
    McKelvie, Ian D.
    Kolev, Spas D.
    ANALYTICAL CHEMISTRY, 2014, 86 (15) : 7274 - 7279
  • [43] Integration of paper-based analytical devices with digital microfluidics for colorimetric detection of creatinine
    Velasco, Larissa G.
    Rocha, Danielly S.
    de Campos, Richard P. S.
    Coltro, Wendell K. T.
    ANALYST, 2024, 150 (01)
  • [44] Research Progress on Electrochemical Paper-Based Analytical Devices for the Detection of Pesticide Residues
    Li, Yanqing
    Zong, Xinrong
    Chen, Si'an
    Zhang, Min
    Shipin Kexue/Food Science, 2024, 45 (15): : 252 - 262
  • [45] Janus Electrochemical Paper-Based Analytical Devices for Metals Detection in Aerosol Samples
    Mettakoonpitak, Jaruwan
    Volckens, John
    Henry, Charles S.
    ANALYTICAL CHEMISTRY, 2020, 92 (01) : 1439 - 1446
  • [46] Strategies for the detection of target analytes using microfluidic paper-based analytical devices
    Wei Zheng
    Kan Wang
    Hao Xu
    Chujun Zheng
    Bo Cao
    Qi Qin
    Qinghui Jin
    Daxiang Cui
    Analytical and Bioanalytical Chemistry, 2021, 413 : 2429 - 2445
  • [47] Strategies for the detection of target analytes using microfluidic paper-based analytical devices
    Zheng, Wei
    Wang, Kan
    Xu, Hao
    Zheng, Chujun
    Cao, Bo
    Qin, Qi
    Jin, Qinghui
    Cui, Daxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (09) : 2429 - 2445
  • [48] Novel concept of washing for microfluidic paper-based analytical devices based on capillary force of paper substrates
    Mohammadi, Saeed
    Alamo Busa, Lori Shayne
    Maeki, Masatoshi
    Mohamadi, Reza M.
    Ishida, Akihiko
    Tani, Hirofumi
    Tokeshi, Manabu
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (27) : 7559 - 7563
  • [49] Paper-based microfluidic analytical devices for colorimetric detection of toxic ions: A review
    Sriram, Ganesan
    Bhat, Mahesh P.
    Patil, Pravin
    Uthappa, Uluvangada T.
    Jung, Ho-Young
    Altalhi, Tariq
    Kumeria, Tushar
    Aminabhavi, Tejraj M.
    Pai, Ranjith Krishna
    Madhuprasad
    Kurkuri, Mahaveer D.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 93 : 212 - 227
  • [50] Paper-Based Analytical Devices for Colorimetric and Luminescent Detection of Mercury in Waters: An Overview
    Bendicho, Carlos
    Lavilla, Isela
    Pena-Pereira, Francisco
    de la Calle, Inmaculada
    Romero, Vanesa
    SENSORS, 2021, 21 (22)