Simultaneous determination of 58 glucocorticoid residues in milk by ultra-high performance liquid chromatography-tandem mass spectrometry

被引:2
作者
Guo, Can [1 ,4 ]
Wu, Cuiling [2 ]
Zhang, Zihao [2 ]
Tan, Sijia [1 ]
Chen, Sumeng [3 ]
Chen, Gang [1 ]
机构
[1] Beijing Technol & Business Univ, Key Lab Geriatr Nutr & Hlth, Minist Educ, Beijing 100048, Peoples R China
[2] Agilent Technol Co Ltd China, Beijing 100102, Peoples R China
[3] China Agr Univ, Beijing 100193, Peoples R China
[4] Chinese Acad Agr Sci, Inst Qual Stand & Testing Technol Agroprod, Beijing 100081, Peoples R China
关键词
Glucocorticoid; Milk; Liquid chromatography -tandem mass; spectrometry; SOLID-PHASE EXTRACTION; LONG-TERM STABILITY; BOVINE-MILK; LC-MS/MS; QUANTITATIVE-DETERMINATION; SYNTHETIC GLUCOCORTICOIDS; ANTIINFLAMMATORY DRUGS; VETERINARY DRUGS; CORTICOSTEROIDS; HORMONES;
D O I
10.1016/j.chroma.2024.464734
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Abuse of glucocorticoid veterinary drugs in dairy industry can potentially threat milk safety and consequently influence human health. Here a reliable method for determination of 58 glucocorticoid drug residues in milk was established by combining solid phase extraction with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The analytes were extracted with acetonitrile and cleanup with EMRLipid lipid removal column. The analytes were chromatographically separated using Poroshell EC-C18 column and acquired by electrospray ionization with multiple-reaction monitoring (MRM) mode. The limit of quantification (S/N >= 10) ranged from 0.2 to 2.0 mu g/kg and the limit of detection (S/N >= 3) ranged from 0.1 to 1.0 mu g/ kg. Average recoveries were from 71% to 113%, the relative standard deviations (RSDs) were less than 15%, and the correlation coefficients (R2) of calibration curves exceeded 0.99. The method was applied to detect twenty milk products obtained from local supermarkets including ten pasteurized milk and ten UHT milk. Two endogenous glucocorticoids, i.e. hydrocortisone and cortisone were detected but not exceed the maximum residue limits (MRLs).
引用
收藏
页数:9
相关论文
共 33 条
[1]  
[Anonymous], 2010, Off. J. Eur. Communities
[2]   Development of an LC-MS/MS method for the determination of endogenous cortisol in hair using 13C3-labeled cortisol as surrogate analyte [J].
Binz, Tina M. ;
Braun, Ueli ;
Baumgartner, Markus R. ;
Kraemer, Thomas .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1033 :65-72
[3]   Residue analysis of glucocorticoids in bovine milk by liquid chromatography-tandem mass spectrometry [J].
Caretti, Fulvia ;
Gentili, Alessandra ;
Ambrosi, Annalisa ;
Rocca, Lucia Mainero ;
Delfini, Maurizio ;
Di Cocco, Maria Enrica ;
D'Ascenzo, Giuseppe .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (06) :2477-2490
[4]   An overview of sample preparation procedures for LC-MS multiclass antibiotic determination in environmental and food samples [J].
Cruz Moreno-Bondi, Maria ;
Dolores Marazuela, Maria ;
Herranz, Sonia ;
Rodriguez, Erika .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (04) :921-946
[5]   Simultaneous Determination of Twelve Glucocorticoids Residues in Milk by Ultra Performance Liquid Chromatography-Electrospray Tandem Mass Spectrometry [J].
Cui Xiaoliang ;
Shao Bing ;
Zhao Rong ;
Meng Juan ;
Tu Xiaoming .
CHINESE JOURNAL OF CHROMATOGRAPHY, 2006, 24 (03) :213-217
[6]   Development and validation of a high-resolution mass-spectrometry-based method to study the long-term stability of natural and synthetic glucocorticoids in faeces [J].
De Clercq, Nathalie ;
Bussche, Julie Vanden ;
Croubels, Siska ;
Delahaut, Philippe ;
Vanhaecke, Lynn .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1336 :76-86
[7]   A validated analytical method to study the long-term stability of natural and synthetic glucocorticoids in livestock urine using ultra-high performance liquid chromatography coupled to Orbitrap-high resolution mass spectrometry [J].
De Clercq, Nathalie ;
Julie, Vanden Bussche ;
Croubels, Siska ;
Delahaut, Philippe ;
Vanhaecke, Lynn .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1301 :111-121
[8]  
EC (European Commission), 2002, OFF J EUR COMMUN L, V221, P8, DOI DOI 10.1017/CBO9781107415324.004
[9]   Review of the pharmacodynamics of antibiotic use in animal food production [J].
Florea, NF ;
Nightingale, CH .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2004, 49 (02) :105-108
[10]   LC-MS methods for analyzing anti-inflammatory drugs in animal-food products [J].
Gentili, Alessandra .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (06) :595-608