A Non-Disposable Electrochemical Sensor Based on Laser-Synthesized Pd/LIG Nanocomposite-Modified Screen-Printed Electrodes for the Detection of H2O2

被引:4
|
作者
Song, Ruijie [1 ]
Zhang, Jianwei [2 ]
Yang, Ge [1 ]
Wu, Yu [1 ]
Yu, Jun [1 ]
Zhu, Huichao [2 ]
机构
[1] Dalian Univ Technol, Dept Sch Med, Dalian 116024, Peoples R China
[2] Dalian Univ Technol, Dept Sch Control Sci & Engn, Dalian 116024, Peoples R China
关键词
nanoparticles; laser-induced graphene; hydrogen peroxide; electrochemical detection; REDUCED GRAPHENE OXIDE; HYDROGEN-PEROXIDE; NANOPARTICLES; ABLATION; REDUCTION; GRAPHITE;
D O I
10.3390/s24072043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There have been many studies on the significant correlation between the hydrogen peroxide content of different tissues or cells in the human body and the risk of disease, so the preparation of biosensors for detecting hydrogen peroxide concentration has been a hot topic for researchers. In this paper, palladium nanoparticles (PdNPs) and laser-induced graphene (LIG) were prepared by liquid-phase pulsed laser ablation and laser-induced technology, respectively. The complexes were prepared by stirring and used for the modification of screen-printed electrodes to develop a non-enzymatic hydrogen peroxide biosensor that is low cost and mass preparable. The PdNPs prepared with anhydrous ethanol as a solvent have a uniform particle size distribution. The LIG prepared by laser direct writing has good electrical conductivity, and its loose porous structure provides more adsorption sites. The electrochemical properties of the modified electrode were characterized by cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy. Compared with bare screen-printed electrodes, the modified electrodes are more sensitive for the detection of hydrogen peroxide. The sensor has a linear response range of 5 mu M-0.9 mM and 0.9 mM-5 mM. The limit of detection is 0.37 mu M. The above conclusions indicate that the hydrogen peroxide electrochemical biosensor prepared in this paper has great advantages and potential in electrochemical catalysis.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Fabrication of Screen-Printed Electrodes Modified by Hydrothermal MnO2 Microflowers and Carbon for Electrochemical Sensors in Copper Ions Detection
    Nguyen, Huyen T. T.
    Chu, Nam T. H.
    Le, Hang T. T.
    JOURNAL OF CHEMISTRY, 2023, 2023
  • [42] CNTs/Graphene Oxide-Nickel Phosphate Nanocomposite-Based Electrochemical Sensor for Detecting H2O2 in Human Serum
    El-Gohary, Asmaa R. M.
    Galal, Ahmed
    Atta, Nada F.
    CHEMISTRYSELECT, 2023, 8 (31):
  • [43] Non-Enzymatic and Highly Sensitive H2O2 Sensor Based on Pd Nanoparticle Modified Gold Nanowire Array Electrode
    Jamal, Mamun
    Hasan, Maksudul
    Mathewson, Alan
    Razeeb, Kafil M.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2012, 159 (11) : B825 - B829
  • [44] A non-enzymatic disposable electrochemical sensor based on surface-modified screen-printed electrode CuO-IL/rGO nanocomposite for a single-step determination of glucose in human urine and electrolyte drinks
    Janmee, Nopparat
    Preechakasedkit, Pattarachaya
    Rodthongkum, Nadnudda
    Chailapakul, Orawon
    Potiyaraj, Pranut
    Ruecha, Nipapan
    ANALYTICAL METHODS, 2021, 13 (25) : 2796 - 2803
  • [45] Electrochemical study of N-acetyl neuraminic acid at gold-modified screen-printed carbon electrodes for a glycoprotein sensor of SARS-CoV-2
    Syaifie, Putri Hawa
    Nasution, Mochammad Arfin Fardiansyah
    Rahmawati, Isnaini
    Saepudin, Endang
    Ivandini, Tribidasari Anggraningrum
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2024, 97 (01)
  • [46] Carbon black assisted tailoring of Prussian Blue nanoparticles to tune sensitivity and detection limit towards H2O2 by using screen-printed electrode
    Cinti, Stefano
    Arduini, Fabiana
    Vellucci, Giada
    Cacciotti, Ilaria
    Nanni, Francesca
    Moscone, Danila
    ELECTROCHEMISTRY COMMUNICATIONS, 2014, 47 : 63 - 66
  • [47] Self-assembled Pt screen printed electrodes with a novel peroxidase Panicum maximum and zinc oxide nanoparticles for H2O2 detection
    Uribe, Paula A.
    Ortiz, Claudia C.
    Centeno, Diana A.
    Castillo, John J.
    Blanco, Sergio, I
    Gutierrez, Jorge A.
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2019, 561 : 18 - 24
  • [48] A new Bluetooth-assisted sensor based on lab-made screen-printed electrode modified with Ni-Ag 2 S for electrochemical detection of triclosan
    Cetiner, Rumeysa
    Sarilmaz, Adem
    Ozel, Faruk
    Bas, Salih Zeki
    Ozmen, Mustafa
    ELECTROCHIMICA ACTA, 2024, 489
  • [49] A novel strategy for rapid, portable, and sensitive detection of Clostridium perfringens cpb2 gene using smartphone-based electrochemical DNA biosensor based on screen-printed electrodes modified with nanocomposite
    Wu, Qianyue
    Yang, Beiying
    Wang, Yutang
    Xiong, Yanyan
    Zhang, Jinhua
    Wen, Yangping
    Rajkovic, Andreja
    MICROCHIMICA ACTA, 2025, 192 (04)
  • [50] A Conductive Metal-Organic Framework Based on Triptycene Ligand: An Effective Electrochemical Sensor for Glucose and H2O2 Detection in Food and Human Serum
    Hu, Qin
    Wu, Jiaying
    Ling, Chengshuang
    Xing, Yun
    Tang, Xin
    Zhang, Yu
    Huang, Ke
    Ye, Jun
    Xiong, Xiaoli
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (03)