A Non-Disposable Electrochemical Sensor Based on Laser-Synthesized Pd/LIG Nanocomposite-Modified Screen-Printed Electrodes for the Detection of H2O2

被引:4
|
作者
Song, Ruijie [1 ]
Zhang, Jianwei [2 ]
Yang, Ge [1 ]
Wu, Yu [1 ]
Yu, Jun [1 ]
Zhu, Huichao [2 ]
机构
[1] Dalian Univ Technol, Dept Sch Med, Dalian 116024, Peoples R China
[2] Dalian Univ Technol, Dept Sch Control Sci & Engn, Dalian 116024, Peoples R China
关键词
nanoparticles; laser-induced graphene; hydrogen peroxide; electrochemical detection; REDUCED GRAPHENE OXIDE; HYDROGEN-PEROXIDE; NANOPARTICLES; ABLATION; REDUCTION; GRAPHITE;
D O I
10.3390/s24072043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There have been many studies on the significant correlation between the hydrogen peroxide content of different tissues or cells in the human body and the risk of disease, so the preparation of biosensors for detecting hydrogen peroxide concentration has been a hot topic for researchers. In this paper, palladium nanoparticles (PdNPs) and laser-induced graphene (LIG) were prepared by liquid-phase pulsed laser ablation and laser-induced technology, respectively. The complexes were prepared by stirring and used for the modification of screen-printed electrodes to develop a non-enzymatic hydrogen peroxide biosensor that is low cost and mass preparable. The PdNPs prepared with anhydrous ethanol as a solvent have a uniform particle size distribution. The LIG prepared by laser direct writing has good electrical conductivity, and its loose porous structure provides more adsorption sites. The electrochemical properties of the modified electrode were characterized by cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy. Compared with bare screen-printed electrodes, the modified electrodes are more sensitive for the detection of hydrogen peroxide. The sensor has a linear response range of 5 mu M-0.9 mM and 0.9 mM-5 mM. The limit of detection is 0.37 mu M. The above conclusions indicate that the hydrogen peroxide electrochemical biosensor prepared in this paper has great advantages and potential in electrochemical catalysis.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Sensing performance of a self-powered electrochemical sensor for H2O2 detection based on microbial fuel cell
    Liu, Weifeng
    Yin, Lin
    Jin, Qi
    Zhu, Yimin
    Zhao, Jiao
    Zheng, Libiao
    Zhou, Zihao
    Zhu, Bin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 832 : 97 - 104
  • [32] A disposable immunomagnetic electrochemical sensor based on functionalised magnetic beads and carbon-based screen-printed electrodes (SPCEs) for the detection of polychlorinated biphenyls (PCBs)
    Centi, S
    Laschi, S
    Fránek, M
    Mascini, M
    ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) : 205 - 212
  • [33] Photoelectrochemical versus Electrochemical Detection of H2O2 Using an All-inorganic Sensor Based on Nanostructured Copper Oxide
    Rehosek, Marco
    Mitoraj, Dariusz
    Bledowski, Michal
    Beranek, Radim
    ELECTROANALYSIS, 2016, 28 (10) : 2327 - 2334
  • [34] Non-enzymatic H2O2 electrochemical sensor based on NiAl-LDH/PPy-Ag composite
    Zhang, Kai
    Zeng, Hong-Yan
    Wang, Ming-Xin
    Li, Zhen
    IONICS, 2022, 28 (12) : 5561 - 5570
  • [35] An electrochemical sensor based on FeCo bimetallic single-atom nanozyme for sensitive detection of H2O2
    Liang, Yi
    Liu, Yiyi
    Zhao, Peng
    Chen, Yuanyuan
    Lei, Jincan
    Hou, Jingzhou
    Hou, Changjun
    Huo, Danqun
    ANALYTICA CHIMICA ACTA, 2023, 1281
  • [36] Non-Enzymatic Amperometric Detection of H2O2 on One-Step Electrochemical Fabricated Cu2O/Electrochemically Reduced Graphene Oxide Nanocomposite
    Dogan, Hulya O.
    Cepni, Emir
    Urhan, Bingul K.
    Eryigit, Mesut
    CHEMISTRYSELECT, 2019, 4 (28): : 8317 - 8321
  • [37] Disposable Electrochemical Ascorbic Acid Sensor Based on Molecularly Imprinted Poly(o-phenylenediamine)-Modified Dual Channel Screen-Printed Electrode for Orange Juice Analysis
    Zhao, Xiaojuan
    Zhang, Wei
    Chen, Haiguang
    Chen, Yuejiao
    Huang, Guiying
    FOOD ANALYTICAL METHODS, 2014, 7 (07) : 1557 - 1563
  • [38] Non-enzymatic Amperometric Sensor for H2O2 Based on MnCO3 Thin Film Electrodes
    Stojkovikj, Sasho
    Najdoski, Metodija
    Sefer, Birhan
    Mirceski, Valentin
    CROATICA CHEMICA ACTA, 2018, 91 (04) : 567 - 575
  • [39] A Novel H2O2 Amperometric Sensor based on Prussian Blue/Palladium Nanoparticles/Graphene Oxide Nanocomposite Modified Electrode
    Ahour, Fatemeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (06): : 812 - 829
  • [40] Electrochemical sensing of H2O2 in food samples using a Bi.Fe-P modified copper Foam-Based sensor
    Hamdi, Fatemeh
    Roushani, Mahmoud
    Ghalkhani, Masoumeh
    MICROCHEMICAL JOURNAL, 2025, 209