A 32-Channel Readout ASIC for X-Ray Spectrometry and Tracking in the GAPS Experiment

被引:1
|
作者
Manghisoni, Massimo [1 ,2 ]
Ghislotti, Luca [1 ,2 ]
Lazzaroni, Paolo [2 ]
Re, Valerio [1 ,2 ]
Riceputi, Elisa [1 ,2 ]
Ratti, Lodovico [2 ,3 ]
Fabris, Lorenzo [4 ]
Boezio, Mirko [5 ]
Zampa, Gianluigi [5 ]
机构
[1] Univ Bergamo, Dipartimento Ingn & Sci Applicate, I-24044 Bergamo, Italy
[2] INFN, Sez Pavia, I-27100 Pavia, Italy
[3] Univ Pavia, Dipartimento Ingn Ind & Informaz, I-27100 Pavia, Italy
[4] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
[5] INFN, Sez Trieste, I-34149 Trieste, Italy
关键词
CMOS; dynamic signal compression; front-end; low-noise; CHARGE SENSITIVE AMPLIFIER; DYNAMIC COMPRESSION; DETECTORS; SIGNAL;
D O I
10.1109/TNS.2023.3336192
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work describes the architecture and the experimental results from the characterization of a 32-channel mixed-signal application-specific integrated circuit (ASIC) developed for the readout of the lithium-drifted silicon (Si(Li)), detectors of the general antiparticle spectrometer (GAPS) experiment dedicated to searching for dark matter. The instrument is designed for the identification of antiprotons, antideuterons, and antihelium nuclei from cosmic rays during an Antarctic balloon mission scheduled for late 2024. A full-custom integrated circuit, named SLIDER32 (32-channel Si-Li detector readout) ASIC, has been produced in a commercial 180-nm CMOS technology. The ASIC comprises 32 low-noise analog readout channels featuring dynamic signal compression to comply with the wide input range, an 11-bit successive approximation register (SAR) analog-to-digital converter (ADC), and a digital back-end section which is responsible for channel setting and for sending digital information to the data acquisition system (DAQ). The circuit design criteria and the experimental results are discussed in this article.
引用
收藏
页码:96 / 105
页数:10
相关论文
共 50 条
  • [41] RG64-High Count Rate Multichannel ASIC with Energy Window Selection for X-ray Imaging Applications
    Szczygiel, R.
    Grybos, P.
    Maj, P.
    Tsukiyama, A.
    Matsushita, K.
    Taguchi, T.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1111 - +
  • [42] X-ray evaluation of the CMOS image sensor IU233N5-Z and readout the scintillation light
    Kayanoki, Taishu
    Takahashi, Hiromitsu
    Niwa, Ryota
    Morishita, Teruaki
    Hashizume, Masaki
    Fukazawa, Yasushi
    Suda, Yusuke
    Kawabata, Koji S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1066
  • [43] Development of a 512-channel module for digital X-ray imaging systems with silicon step detectors
    Bolanos, L.
    Cabal, A. E.
    Grybos, P.
    Maj, P.
    Marzari, A.
    Prino, F.
    Ramello, L.
    Swientek, K.
    Szczygiel, R.
    MEDICAL PHYSICS, 2008, 1032 : 229 - 232
  • [44] Continued developments in X-ray speed reading: fast, low noise readout for next-generation wide-field imagers
    Herrmann, Sven C.
    Orel, Peter
    Chattopadhyay, Tanmoy
    Morris, Glenn R.
    Prigozhin, Gregory Y.
    Stueber, Haley R.
    Allen, Steven W.
    Bautz, Marshall W.
    Donlon, Kevan
    LaMarr, Beverly J.
    Leitz, Christopher W.
    Miller, Eric D.
    Pan, Abby
    Poliszczuk, Artem
    Wilkins, Dan R.
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY XI, 2024, 13103
  • [45] Simulations and measurements of the background encountered by a high-altitude balloon-borne experiment for hard X-ray astronomy
    Lum, KSK
    Mohr, JJ
    Barret, D
    Grindlay, JE
    Manandhar, RP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 396 (03): : 350 - 359
  • [46] Single Photon-Counting Pixel Readout Chip Operating up to 1.2 Gcps/mm2 for Digital X-Ray Imaging Systems
    Kleczek, Rafal
    Grybos, Pawel
    Szczygiel, Robert
    Maj, Piotr
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2018, 53 (09) : 2651 - 2662
  • [47] A new structure of an n-channel junction field-effect transistor embedded in a pin diode for an X-ray detector
    Matsuura, H
    Nishida, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1998, 37 (2A): : L115 - L118
  • [48] Channel Hot Carrier Stress on Irradiated 130-nm NMOSFETs: Impact of Bias Conditions During X-ray Exposure
    Silvestri, M.
    Gerardin, S.
    Paccagnella, A.
    Faccio, F.
    Gonella, L.
    Pantano, D.
    Re, V.
    Manghisoni, M.
    Ratti, L.
    Ranieri, A.
    RADECS 2007: PROCEEDINGS OF THE 9TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS, 2007, : 73 - +
  • [49] SENSROC5: a 16-channel Radiation-Hardness Low-Noise Front-End ASIC Dedicated to CZT Detectors for X- and γ-Ray Imaging
    Gao, W.
    Gao, D.
    Wei, T.
    Hu, Y.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [50] Microstructural analysis of GaN films grown on (100) MgF2 substrate by 4D nanobeam diffraction and energy-dispersive X-ray spectrometry
    Niemeyer, Tobias
    Meyer, Kevin
    Flathmann, Christoph
    Meyer, Tobias
    Schaadt, Daniel M.
    Seibt, Michael
    JOURNAL OF CRYSTAL GROWTH, 2023, 602