Evaluation of energy-saving potential and indoor thermal environment of passive solar houses in various heating climate regions of China

被引:3
作者
Li, Gaochao [1 ,2 ]
Gu, Wenbo [1 ,2 ,3 ]
Xiermaimaiti, Arepati [1 ,2 ]
机构
[1] Xinjiang Univ, Sch Elect Engn, Urumqi, Peoples R China
[2] Xinjiang Univ, Engn Res Ctr Northwest Energy Carbon Neutral, Minist Educ ERCNECN, Urumqi, Peoples R China
[3] Xinjiang Univ, Sch Elect Engn, Urumqi 830017, Xinjiang, Peoples R China
关键词
Diverse passive heating climate regions; energy consumption; indoor thermal environment; PCM floors; DeST-S; PERFORMANCE; DESIGN;
D O I
10.1080/15567036.2024.2339528
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Passive solar houses comprise crucial strategies of reducing heating and cooling energy for buildings, which have been extensively used in plenty of nations. This study develops a study on indoor thermal environment, the energy-saving performance and natural lighting in different heating climate regions (represented by Lhasa, Xining and Urumqi). An attached-sunspace solar house integrated with phase change material floors is also proposed to ameliorate indoor thermal comfort and simultaneously diminish the heating energy consumption. In addition, the dominant factors analysis of building envelope affecting building energy consumption are sensitively studied. Moreover, the influence of the depth of sunspace and the intensities of internal heat gain on indoor thermal conditions and heating energy consumption are further analyzed. The results indicate that among the three types of solar houses, the passive solar sunspace offers the most stable indoor temperature and Trombe-wall solar houses and attached-sunspace solar houses have striking energy-saving advantages compared with the traditional houses. And the annual power consumption of 695.1 kWh, 427.4 kWh and 688.8 kWh in Lhasa, Xining and Urumqi can be saved in view of natural lighting respectively. Additionally, the whole natural temperature of attached-sunspace solar house is on the rise apparently when the PCM floors are embedded in the house and the energy saving fraction of these three regions is 81.9% for Lhasa, 68.8% for Xining, 55.7% for Urumqi respectively with the integration of phase change floors. The sensitivity analysis of key parameters impacting building energy consumption from high to low are the heat transfer coefficient of external wall, the ratio of window to wall, air tightness, the heat transfer coefficient of external window, and the heat transfer coefficient of roof. The depth of 1.2 m for sunspace is recommended as the optimal choice. Indoor natural temperature is on the rise as intensities of internal heat gain increase. The same downward trend for the main bedroom and the whole building is displayed with the increasing interior heat sources in terms of annual heating load.
引用
收藏
页码:5363 / 5381
页数:19
相关论文
共 27 条
[1]  
[Anonymous], 2012, JGJ/T 267-2012
[2]  
[Anonymous], 2003, GB 50019-2003 Code for design of heating ventilation and air conditioning
[3]   Analysis of thermal performance of building attached sunspace [J].
Bataineh, Khaled M. ;
Fayez, Nadia .
ENERGY AND BUILDINGS, 2011, 43 (08) :1863-1868
[4]   Characterizing the performance of a passive solar house with hydronic floor energy capture system - Heating season experiments [J].
Brown, Sarah ;
Beausoleil-Morrison, Ian .
ENERGY AND BUILDINGS, 2021, 252
[5]   Performance assessment of a passive solar building for thermal comfort and energy saving in a hilly terrain of India [J].
Chandel, S. S. ;
Sarkar, Amitava .
ENERGY AND BUILDINGS, 2015, 86 :873-885
[6]   Energy, economic and environmental benefits of integrating passive design strategies into buildings: A review [J].
Elaouzy, Y. ;
El Fadar, A. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 167
[7]   Use of sunspaces to obtain energy savings by preheating the intake air of the ventilation system: Analysis of its main characteristics in the different Spanish climate zones [J].
Gainza-Barrencua, J. ;
Odriozola-Maritorena, M. ;
Barrutieta, X. ;
Gomez-Arriaran, I ;
Hernandez Minguillon, Rufino .
JOURNAL OF BUILDING ENGINEERING, 2022, 62
[8]   Creating glazed facades performance map based on energy and thermal comfort perspective for office building design strategies in Asian hot-humid climate zone [J].
Hwang, Ruey-Lung ;
Chen, Wei-An .
APPLIED ENERGY, 2022, 311
[9]  
Jian Y., 2002, Housing Science, V7, P3
[10]  
Jiang Y., 2006, Building environmental system simulation and analysis-DeST