Development of a fast RP-HPLC method for the separation of nifurtimox and its forced degradation products through a design of experiment approach

被引:3
作者
Bedogni, Giselle [1 ]
Azcarate, Federico [2 ,3 ]
Seremeta, Katia [4 ]
Okulik, Nora [4 ]
Salomon, Claudio [1 ,3 ]
Boschetti, Carlos [2 ,3 ]
机构
[1] Consejo Nacl Invest Cient & Tecn IQUIR CONICET, Inst Quim Rosario, Suipacha 570, RA-2000 Rosario, Argentina
[2] Consejo Nacl Invest Cient & Tecn IPROBYQ CONICET, Inst Proc Biotecnol & Quim, Suipacha 570, RA-2000 Rosario, Argentina
[3] Univ Nacl Rosario, Fac Ciencias Bioquim & Farmaceut, Suipacha 570, RA-2000 Rosario, Argentina
[4] Univ Nacl Chaco Austral INIPTA CONICET UNCAUS, Consejo Nacl Invest Cient & Tecn, Inst Invest Proc Tecnol Avanzados, Cte Fernandez 755, RA-3700 Presidencia Roque Saenz P, Argentina
关键词
Design of Experiments; Method development; Nifurtimox; HPLC; VALIDATION;
D O I
10.1016/j.molliq.2024.124293
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The study depicts the successful development and validation of a simple and fast reverse -phase high-performance liquid chromatography (RP-HPLC) method for the separation of nifurtimox (NFX) and its degradation products. NFX was exposed to different degradation conditions and a RP-HPLC method reported in the literature was used to evaluate different peaks that could interfere with the one from the pure NFX. NaOH generated a degradation product, with a peak that tends to overlap with NFX. Therefore, the NFX exposed to this condition was used during screening and optimization of the RP-HPLC method using a Design of Experiment (DoE) approach. A factorial design was applied to screen different factors, followed by a central composite design for process optimization with those factors that significantly affected the evaluated responses during the screening step. The optimized method was further validated according to International Conference of Harmonization guidelines. Methanol proportion and gradient time to reach it, alongside with mobile phase flow rate, were the factors that had a statistically significant effect on resolution, retention time, and tailing factor in the chromatographic peak. The optimized chromatographic parameters were: 41.6 % of methanol, a gradient time of 2 min, and a flow rate of 0.62 mL/min. Under these chromatographic conditions, the retention time of NFX was 5.3 min, while for the nearest degradation products was 4.5 min and 6.3 min. The resolution of the NFX peak was 5.14 and the tailing was 1.13. The DoE approach allowed the development of an optimized RP-HPLC method capable of successfully separating NFX and its forced degradation products.
引用
收藏
页数:8
相关论文
共 33 条
[1]  
[Anonymous], 2006, INT C HARM GUID Q3B
[2]  
[Anonymous], 2017, INT C HARM GUID Q8 R
[3]   Development and Validation of a Stability-Indicating HPLC Method for Imidapril and Its Degradation Products Using a Design of Experiment (DoE) Approach [J].
Arumugam, Abiramasundari ;
Joshi, Amita ;
Vasu, Kamala K. .
JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (06) :1727-1738
[4]   The analysis of transformations for profit-and-loss data [J].
Atkinson, Anthony C. ;
Riani, Marco ;
Corbellini, Aldo .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES C-APPLIED STATISTICS, 2020, 69 (02) :251-275
[5]  
Bhattacharya S., 2021, RESPONSE SURFACE MET, DOI [10.5772/intechopen.95835, DOI 10.5772/INTECHOPEN.95835]
[6]   Nitrofurantoin hydrolytic degradation in the environment [J].
Biosic, Martina ;
Skoric, Irena ;
Beganovic, Jasmina ;
Babic, Sandra .
CHEMOSPHERE, 2017, 186 :660-668
[7]   The contemporary distribution of Trypanosoma cruzi infection in humans, alternative hosts and vectors [J].
Browne, Annie J. ;
Guerra, Carlos A. ;
Alves, Renato Vieira ;
da Costa, Veruska Maia ;
Wilson, Anne L. ;
Pigott, David M. ;
Hay, Simon I. ;
Lindsay, Steve W. ;
Golding, Nick ;
Moyes, Catherine L. .
SCIENTIFIC DATA, 2017, 4
[8]   Chemometrics Approaches in Forced Degradation Studies of Pharmaceutical Drugs [J].
de Alvarenga Junior, Benedito Roberto ;
Carneiro, Renato Lajarim .
MOLECULES, 2019, 24 (20)
[9]   Reactions of nifurtimox with critical sulfhydryl-containing biomolecules:: their potential toxicological relevance [J].
Díaz, EG ;
de Mecca, MM ;
Castro, JA .
JOURNAL OF APPLIED TOXICOLOGY, 2004, 24 (03) :189-195
[10]   Oxidation of Drugs during Drug Product Development: Problems and Solutions [J].
Gabric, Alen ;
Hodnik, Ziga ;
Pajk, Stane .
PHARMACEUTICS, 2022, 14 (02)