Real-Time Quantitative Evaluation of a Drug during Liposome Preparation Using a Probe-Type Raman Spectrometer

被引:1
|
作者
Sato, Takumi [1 ]
Haneishi, Kazuki [1 ]
Hisada, Hiroshi [1 ]
Fujii, Mika Yoshimura [1 ]
Koide, Tatsuo [2 ]
Fukami, Toshiro [1 ]
机构
[1] Meiji Pharmaceut Univ, Dept Mol Pharmaceut, Kiyose, Tokyo 2048588, Japan
[2] Natl Inst Hlth Sci, Kawasaki, Kanagawa 2109501, Japan
基金
日本学术振兴会;
关键词
CIPROFLOXACIN; DOXORUBICIN; SPECTROSCOPY; VESICLES; MODEL;
D O I
10.1021/acs.langmuir.3c03872
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
During the manufacturing process of liposome formulations, it is considered difficult to evaluate their physicochemical properties and biological profiles due to the complexity of their structure and manufacturing process. Conventional quality evaluation is labor-intensive and time-consuming; therefore, there was a need to introduce a method that could perform in-line, real-time evaluation during the manufacturing process. In this study, Raman spectroscopy was used to monitor in real time the encapsulation of drugs into liposomes and the drug release, which are particularly important quality evaluation items. Furthermore, Raman spectroscopy combined with partial least-squares (PLS) analysis was used for quantitative drug evaluation to assess consistency with results from UV-visible spectrophotometry (UV), a common quantification method. The prepared various ciprofloxacin (CPFX) liposomes were placed in cellulose tubes, and a probe-type Raman spectrophotometer was used to monitor drug encapsulation, the removal of unencapsulated drug, and drug release characteristics in real time using a dialysis method. In the Raman spectra of the liposomes prepared by remote loading, the intensities of the CPFX-derived peaks increased upon drug encapsulation and showed a slight decrease upon removal of the unencapsulated drug. Furthermore, the peak intensity decreased more gradually during the drug release. In all Raman monitoring experiments, the discrepancy between quantified values of CPFX concentration in liposomes, as measured by Raman spectroscopy combined with partial least-squares (PLS) analysis, and those obtained through ultraviolet (UV) spectrophotometry was within 6.7%. The results revealed that the quantitative evaluation of drugs using a combination of Raman spectroscopy and PLS analysis was as accurate as the evaluation using UV spectrophotometry, which was used for comparison. These results indicate the promising potential of Raman spectroscopy as an innovative method for the quality evaluation of liposomal formulations.
引用
收藏
页码:7962 / 7973
页数:12
相关论文
共 50 条
  • [1] Real-Time Formation Monitoring of Cocrystals with Different Stoichiometries Using Probe-Type Low-Frequency Raman Spectroscopy
    Inoue, Motoki
    Hisada, Hiroshi
    Koide, Tatsuo
    Carriere, James
    Heyler, Randy
    Fukami, Toshiro
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2017, 56 (44) : 12693 - 12697
  • [2] Monitoring the Dissolution Behavior of Novel Pharmaceutical Cocrystals Consisting of Antimalarial Drug Artemisinin with Probe-Type Low-Frequency Raman Spectrometer
    Kudo, Takayuki
    Miura, Soichiro
    Takatori, Kazuhiko
    Titapiwatanakun, Varin
    Palanisamy, Vasanthi
    Yamamoto, Katsuhiko
    Ikeda, Yukihiro
    Fukami, Toshiro
    APPLIED SPECTROSCOPY, 2024, 78 (11) : 1125 - 1135
  • [3] Real-Time Sample Analysis Using a Sampling Probe and Miniature Mass Spectrometer
    Chen, Chien-Hsun
    Lin, Ziqing
    Tian, Ran
    Shi, Riyi
    Cooks, R. Graham
    Ouyang, Zheng
    ANALYTICAL CHEMISTRY, 2015, 87 (17) : 8867 - 8873
  • [4] Evaluation of real-time imaging using a laparoscopic ultrasound probe during operative endoscopic procedures
    Letterie, GS
    Marshall, L
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (01) : 63 - 67
  • [5] EVALUATION OF THE VAGINAL MICROBIOTA USING QUANTITATIVE REAL-TIME PCR
    Shalepo, K.
    Nazarova, V.
    Menukhova, J.
    Savicheva, A.
    SEXUALLY TRANSMITTED INFECTIONS, 2013, 89 : A96 - A96
  • [6] A novel real-time quantitative PCR method using attached universal template probe
    Zhang, YL
    Zhang, DB
    Li, WQ
    Chen, JQ
    Peng, YF
    Cao, W
    NUCLEIC ACIDS RESEARCH, 2003, 31 (20)
  • [7] Quantitative detection method of Enterocytozoon hepatopenaei using TaqMan probe real-time PCR
    Liu, Ya-Mei
    Qiu, Liang
    Sheng, An-Zhi
    Wan, Xiao-Yuan
    Cheng, Dong-Yuan
    Huang, Jie
    JOURNAL OF INVERTEBRATE PATHOLOGY, 2018, 151 : 191 - 196
  • [8] Real-time Quantitative Monitoring of Synthesis Process of Clevidipine Butyrate Using Raman Spectroscopy
    Liu Yan-Hua
    Zhang Jun-Dong
    Yan Kun
    Wei Yu-Jiao
    Zhang Qian-Qian
    Lu Feng
    Yan Zheng-Yu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (02) : E1701 - E1708
  • [9] A simulation evaluation of a real-time traffic information system using probe vehicles
    Dai, XW
    Ferman, MA
    Roesser, RP
    2003 IEEE INTELLIGENT TRANSPORTATION SYSTEMS PROCEEDINGS, VOLS. 1 & 2, 2003, : 475 - 480
  • [10] REAL-TIME ESTIMATION OF MICROBIAL BIOMASS DURING FERMENTATIONS, USING A DIELECTRIC PROBE
    KELL, DB
    SAMWORTH, CM
    TODD, RW
    BUNGARD, SJ
    MORRIS, JG
    STUDIA BIOPHYSICA, 1987, 119 (1-3): : 153 - 156