Grid Strength Impedance Metric: An Alternative to SCR for Evaluating System Strength in Converter Dominated Systems

被引:14
作者
Henderson, Callum [1 ]
Egea-Alvarez, Agusti [1 ]
Kneuppel, Thyge [2 ]
Yang, Guangya [3 ]
Xu, Lie [1 ]
机构
[1] Univ Strathclyde, EEE Dept, PEDEC Grp, Glasgow G1 1XQ, Scotland
[2] Siemens Gamesa Renewable Energy A S, DK-7330 Brande, Denmark
[3] Tech Univ Denmark, DTU Wind, PWR Grp, DK-2800 Lyngby, Denmark
基金
英国工程与自然科学研究理事会;
关键词
Impedance; Power system stability; Measurement; Fault currents; Circuit stability; Voltage control; Phase locked loops; Short circuit ratio; grid stiffness; converter impedance; power system stability; grid forming converters; VECTOR CONTROL; POWER; STABILITY;
D O I
10.1109/TPWRD.2022.3233455
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Short circuit ratio is an outdated measure of system strength in converter dominated systems as the useful behaviour of inverter-based resources is not represented. While still useful for determining fault current provision, converter connected generation contributes to short circuit level and system strength in a different way to traditional synchronous generation. Additionally, traditional measures only account for system strength at the fundamental frequency while converters possess complex interactions across a frequency range. A novel method of determining system strength across this frequency range from the network impedances is proposed in this paper. The approach known as the Grid Strength Impedance Metric, calculates the system strength independently from short circuit level. The unique contribution of grid-following and grid-forming converters is represented by including the multiple-input multiple-output converter output impedances in the calculation. Small-signal impedance models are employed, and the metric is largely concerned with short-term voltage stability, but some inferences can be made for longer timescales. The approach is validated using time domain simulations to check for any identified areas of weakness in the frequency range. The Grid Strength Impedance Metric successfully represents the useful behaviour of grid-forming converters, indicating an enhancement in voltage stiffness in locations of deployment.
引用
收藏
页码:386 / 396
页数:11
相关论文
共 37 条
[1]  
Abdelrahim A., 2019, PROC 18 INT WINDINTE
[2]   New Fault Detection Algorithm for an Improved Dual VSM Control Structure With FRT Capability [J].
Abdelrahim, Ahmed ;
Smailes, Michael ;
Ahmed, Khaled H. ;
Mckeever, Paul ;
Egea-Alvarez, Agusti .
IEEE ACCESS, 2021, 9 :125134-125150
[3]  
Achilles S., 2017, INTEGRATING INVERTER
[4]  
[Anonymous], 2016, CIGRE working group B4.562
[5]  
Bolzoni A, 2020, IEEE W CONTR MODEL, P145
[6]   Subsynchronous Oscillation and Advanced Analysis: A Review [J].
Damas, Robin Noel ;
Son, Yongju ;
Yoon, Myungseok ;
Kim, Sung-Yul ;
Choi, Sungyun .
IEEE ACCESS, 2020, 8 (08) :224020-224032
[7]   Robust Vector Control of a Very Weak-Grid-Connected Voltage-Source Converter Considering the Phase-Locked Loop Dynamics [J].
Davari, Masoud ;
Mohamed, Yasser Abdel-Rady I. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (02) :977-994
[8]  
Department for Business Energy and Industrial Strategy, 2021, Energytrends U.K., April to June 2021, statistical release
[9]   Advanced Vector Control for Voltage Source Converters Connected to Weak Grids [J].
Egea-Alvarez, Agust ;
Fekriasl, Sajjad ;
Hassan, Fainan ;
Gomis-Bellmunt, Oriol .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (06) :3072-3081
[10]  
Fernades R., 2015, Report to NERC ERSTF forcomposite short circuit ratio (CSCR) estimation guideline