Dual threshold input receiver FPGA-only signal digitization method for time-of-flight positron emission tomography

被引:3
|
作者
Ko, Guen Bae [1 ,2 ]
Lee, Jae Sung [1 ,2 ,3 ,4 ]
机构
[1] Brightonix Imaging Inc, Seoul 04782, South Korea
[2] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul 03080, South Korea
[3] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul 03080, South Korea
[4] Seoul Natl Univ, Coll Engn, Interdisciplinary Program Bioengn, Seoul 03080, South Korea
关键词
Positron emission tomography; Field-programmable gate array; Silicon photomultiplier; Time-to-digital converter; Time-over-threshold; PET; PET/MRI;
D O I
10.1007/s13534-024-00380-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As silicon photomultiplier (SiPM)-based time-of-flight (TOF) positron emission tomography (PET) becomes popular, the need for sophisticated PET data acquisition (DAQ) systems is increasing. One promising solution to this challenge is the adoption of a field-programmable gate array (FPGA)-only signal digitization method. In this paper, we propose a new approach to efficiently implement an FPGA-only digitizer. We configured the input/output (IO) port of the FPGA to function as a dual-threshold voltage comparator through the use of simple passive circuitry and heterogeneous IO standards. This configuration overcomes the limitations of existing methods by allowing different threshold voltages for adjacent IO pins, effectively reducing routing complexity and lowering manufacturing costs. An FPGA-only digitizer was implemented by integrating the dual-threshold voltage comparator and FPGA-based time-to-digital converter. By combining the dual-threshold time-over-threshold (TOT) method and curve fitting, precise energy information could be obtained. The performance of the FPGA-only digitizer was assessed using a detector setup comprising a 3 x 3 x 20 mm3 LYSO scintillation crystal and a single pixel SiPM. Using the configured evaluation setup, an energy resolution of 12.5% and a time resolution of 146 +/- 9 ps were achieved for a 20 mm scintillation crystal. The dual-threshold TOT implemented using the proposed method showed consistent linearity across an energy range of 100 keV to 600 keV. The proposed method is well-suited for the development of cost-effective DAQ systems in highly integrated TOF PET systems.
引用
收藏
页码:847 / 858
页数:12
相关论文
共 42 条
  • [21] Segmented SiPM Readout for Cherenkov Time-of-Flight Positron Emission Tomography Detectors Based on Bismuth Germanate
    Yi, Minseok
    Lee, Daehee
    Gola, Alberto
    Merzi, Stefano
    Penna, Michele
    Lee, Jae Sung
    Cherry, Simon R.
    Kwon, Sun Il
    ACS PHOTONICS, 2025, 12 (02): : 1125 - 1136
  • [22] Wavelength discrimination (WLD) detector optimization for time-of-flight positron emission tomography with depth of interaction information
    Ullah, Muhammad Nasir
    Park, Jin Ho
    Pratiwi, Eva
    Kim, Gyeong Beom
    Yeom, Jung-Yeol
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 982
  • [23] Readout Electronics and Data Acquisition of a Positron Emission Tomography Time-of-Flight Detector Module With Waveform Digitizer
    Yeom, Jung Yeol
    Vinke, Ruud
    Spanoudaki, Virginia Ch
    Hong, Key Jo
    Levin, Craig S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3735 - 3741
  • [24] Feasibility Study of a Time-of-Flight Brain Positron Emission Tomography Employing Individual Channel Readout Electronics
    Park, Kuntai
    Jung, Jiwoong
    Choi, Yong
    Leem, Hyuntae
    Kim, Yeonkyeong
    SENSORS, 2021, 21 (16)
  • [25] Relationship between the image quality and noise-equivalent count in time-of-flight positron emission tomography
    Maebatake, Akira
    Akamatsu, Go
    Miwa, Kenta
    Tsutsui, Yuji
    Himuro, Kazuhiko
    Baba, Shingo
    Sasaki, Masayuki
    ANNALS OF NUCLEAR MEDICINE, 2016, 30 (01) : 68 - 74
  • [27] SensL B-Series and C-Series silicon photomultipliers for time-of-flight positron emission tomography
    O'Neill, K.
    Jackson, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 169 - 172
  • [28] An investigation of optimal photomultiplier signal delay method on detector time resolution in positron emission tomography
    Aykac, Mehmet
    Cho, Sanghee
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 641 (01) : 141 - 145
  • [29] The high matrix acquisition technique for imaging of atherosclerotic plaque inflammation in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography with time-of-flight: Phantom study
    Suda, Masaya
    Kiriyama, Tomonari
    Ishihara, Keiichi
    Onoguchi, Masahisa
    Kobayashi, Yasuhiro
    Sakurai, Minoru
    Shibutani, Takayuki
    Kumita, Shin-ichiro
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1161 - 1170
  • [30] A CMOS Time-to-digital converter for multi-voltage threshold method in Positron Emission Tomography
    Li, Yan
    Yu, Hang
    Jiang, Lai
    Ji, Zhen
    Zhu, Jun
    Niu, Ming
    Xiao, Peng
    2013 IEEE INTERNATIONAL CONFERENCE OF ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC), 2013,