Analysis and investigation of synchronous machine rotor winding short-circuit fault in a distribution system

被引:0
作者
Dhara, Saumen [1 ]
Shrivastav, Alok Kumar [2 ]
Bhaumik, Kallol [3 ]
Sadhu, Pradip Kumar [4 ]
机构
[1] Greater Kolkata Coll Engn & Management, Elect Engn Dept, Kolkata 743387, West Bengal, India
[2] JIS Coll Engn, Elect Engn Dept, Kalyani 741235, West Bengal, India
[3] Malla Reddy Engn Coll & Management Sci, EEE Dept, Hyderabad 501401, Telangana, India
[4] IIT ISM, Dept Elect Engn, Dhanbad 826004, Jharkhand, India
来源
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | 2024年 / 30卷 / 10期
关键词
INDUCTION GENERATOR; DIAGNOSIS;
D O I
10.1007/s00542-024-05640-z
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Rotor turn short circuit fault of permanent magnet synchronous machines (PMSMs) in the distribution system has a significant issue caused by unbalance loading. This fault has a significant electromagnetic impact on the rotor winding in relation to the machine's external equipment. As a result, while designing the power system distribution network, the PMSMs rotor winding short circuit current limitation receives majority of attention. For simulation a 3-phase short-circuit model of synchronous generator is developed here by using MATLAB/SIMULINK software. Therefore, a method is used to determine a PMSM's internal winding quantity in the event of a short circuit, as well as its location within the distribution network. The PMSM is energized with a small sinusoidal voltage at standstill situation in this suggested approach to compute the synchronous inductance and winding resistance through the output current. It has been demonstrated that the number of shorted windings may be calculated using the variation of output current caused by an internal winding short circuit event under zero fault resistance condition. Except for intricate machine modelling or investigation of machine internal winding short circuit models comprising several tappings, this useful technique can be used to determine fault intensity for a specific synchronous machine. This paper primarily addressed on fault extremity protection strategies using before-fault and after-fault activities by employing harmonic filters. A three-phase synchronous machine model with a protective system is implemented in the distribution network using MATLAB/SIMULINK is taken into consideration in order to verify the findings. The results presented in this work are vital to a complete solution that includes fault reduction techniques. Harmonics elimination and instant fault mitigation techniques with load unbalancing are analyzed based on effective outcomes to judge the system stability and feasibility of the short circuit current intensity assessment.
引用
收藏
页码:1259 / 1274
页数:16
相关论文
共 50 条
  • [21] Probabilistic Diagnosis of Short Circuit Fault in Stator Winding of Motor Based on Feature Distribution
    Fukui, Hiroyuki
    Mizuno, Yukio
    Nakamura, Hisahide
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [22] The Detection of an Inter-Turn Short-Circuit Fault in a Brushless Permanent Magnet Motor with Different Winding Configurations
    Korkosz, Mariusz
    Prokop, Jan
    Ryllo, Karol
    ENERGIES, 2024, 17 (24)
  • [23] Detection of Interturn Short-Circuit Fault for PMSM With Simple Fault Indicator
    Hang, Jun
    Ding, Shichuan
    Zhang, Jianzhong
    Cheng, Ming
    Chen, Wen
    Wang, Qunjing
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) : 1697 - 1699
  • [24] Modeling and detection of the short-circuit fault in PMSM using Finite Element Analysis
    Fitouri, Manel
    Bensalem, Yemna
    Abdelkrim, Mohamed Naceur
    IFAC PAPERSONLINE, 2016, 49 (12): : 1418 - 1423
  • [25] Analysis and Monitoring Method for Inter-Turn Short-Circuit Fault for PMSM
    Liu, Chengsi
    Xiao, Lijun
    Zou, Jibin
    Xu, Yongxiang
    Li, Shaobin
    IEEE TRANSACTIONS ON MAGNETICS, 2023, 59 (11)
  • [26] Research on Interturn Short-Circuit Fault Indicators for Direct-Drive Permanent Magnet Synchronous Motor
    Gao, Caixia
    Lv, Ke
    Si, Jikai
    Feng, Haichao
    Hu, Yihua
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2022, 10 (02) : 1902 - 1914
  • [27] On-Line Detection of Stator Winding Short-Circuit Faults in a PM Machine using HF Signal Injection
    Arellano-Padilla, Jesus
    Sumner, Mark
    Gerada, Chris
    ICEM: 2008 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES, VOLS 1- 4, 2009, : 1526 - 1533
  • [28] Performance Evaluation and Remedial Strategy of Synchronous Reluctance Motor Drive under Winding Turn Short Circuit Fault
    Bouchareb, I.
    Bentounsi, A.
    Lebaroud, A.
    2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2016, : 2313 - 2320
  • [29] Research on Fault Characteristics of Direct-drive Permanent Synchronous Motor with Stator Winding Inter-turn Short Circuit Fault
    Gao, Caixia
    Lv, Ke
    Si, Jikai
    Feng, Haichao
    Xu, Xiaozhuo
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 2051 - 2055
  • [30] Probabilistic diagnosis of short-circuit faults and insulation deterioration of stator winding of motor
    Nakamura, Hisahide
    Mizuno, Yukio
    ELECTRICAL ENGINEERING IN JAPAN, 2013, 184 (01) : 30 - 41