The infraacetabular screw versus the antegrade posterior column screw in acetabulum fractures with posterior column involvement: a biomechanical comparison

被引:2
作者
Hinz, Nico [1 ,2 ]
Baumeister, Dirk [3 ]
Dehoust, Julius [2 ]
Muench, Matthias [4 ]
Frosch, Karl-Heinz [1 ,2 ]
Augat, Peter [3 ]
Hartel, Maximilian J. [1 ,2 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Trauma & Orthopaed Surg, Martinistr 52, D-20246 Hamburg, Germany
[2] BG Klinikum Hamburg, Dept Trauma Surg Orthopaed & Sports Traumatol, Bergedorfer Str 10, D-21033 Hamburg, Germany
[3] BG Unfallklin Murnau, Inst Biomech, Prof Kuentscher Str 8, D-82418 Murnau Am Staffelsee, Germany
[4] BG Klinikum Hamburg, Lab Biomech, Bergedorfer Str 10, D-21033 Hamburg, Germany
关键词
Acetabulum fracture; Anterior column plus posterior hemitransverse fracture; Antegrade posterior column screw; Infraacetabular screw; Suprapectineal plate; Biomechanical testing; HIP FRACTURE; FIXATION STRENGTH; ANTERIOR COLUMN; SURGERY; OLDER; POPULATION; AMBULATION; PLACEMENT; OUTCOMES;
D O I
10.1007/s00402-024-05324-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Traditionally, plate osteosynthesis of the anterior column combined with an antegrade posterior column screw is used for fixation of anterior column plus posterior hemitransverse (ACPHT) acetabulum fractures. Replacing the posterior column screw with an infraacetabular screw could improve the straightforwardness of acetabulum surgery, as it can be inserted using less invasive approaches, such as the AIP/Stoppa approach, which is a well-established standard approach. However, the biomechanical stability of a plate osteosynthesis combined with an infraacetabular screw instead of an antegrade posterior column screw is unknown. Material and methods Two osteosynthesis constructs were compared in a synthetic hemipelvis model with an ACPHT fracture: Suprapectineal plate + antegrade posterior column screw (APCS group) vs. suprapectineal plate + infraacetabular screw (IAS group). A single-leg stance test protocol with an additional passive muscle force and a cyclic loading of 32,000 cycles with a maximum effective load of 2400 N was applied. Interfragmentary motion and rotation of the three main fracture lines were measured. Results At the posterior hemitransverse fracture line, interfragmentary motion perpendicular to the fracture line (p < 0.001) and shear motion (p < 0.001) and at the high anterior column fracture line, interfragmentary motion longitudinal to the fracture line (p = 0.017) were significantly higher in the IAS group than in the APCS group. On the other hand, interfragmentary motion perpendicular (p = 0.004), longitudinal (p < 0.001) and horizontal to the fracture line (p = 0.004) and shear motion (p < 0.001) were significantly increased at the low anterior column fracture line in the APCS group compared to the IAS group. Conclusions Replacing the antegrade posterior column screw with an infraacetabular screw is not recommendable as it results in an increased interfragmentary motion, especially at the posterior hemitransverse component of an ACPHT fracture.
引用
收藏
页码:2573 / 2582
页数:10
相关论文
共 53 条
  • [21] Computational analysis of the safe zone for the antegrade lag screw in posterior column fixation with the anterior approach in acetabular fracture: A cadaveric study
    Jung, Gu-Hee
    Lee, Yongkoo
    Kim, Joon-Woo
    Kim, Ji-wan
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (03): : 608 - 614
  • [22] Kamel HK, 2003, J GERONTOL A-BIOL, V58, P1042
  • [23] Inability of Older Adult Patients with Hip Fracture to Maintain Postoperative Weight-Bearing Restrictions
    Kammerlander, Christian
    Pfeufer, Daniel
    Lisitano, Leonard Adolf
    Mehaffey, Stefan
    Boecker, Wolfgang
    Neuerburg, Carl
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (11) : 936 - 941
  • [24] Rationales for the Bernese approaches in acetabular surgery
    Keel, M. J. B.
    Ecker, T. M.
    Siebenrock, K. -A.
    Bastian, J. D.
    [J]. EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2012, 38 (05) : 489 - 498
  • [25] THE PARARECTUS APPROACH A New Concept
    Keel, Marius J. B.
    Siebenrock, Klaus-Arno
    Tannast, Moritz
    Bastian, Johannes D.
    [J]. JBJS ESSENTIAL SURGICAL TECHNIQUES, 2018, 8 (03):
  • [26] Surgical management of acetabular fractures - A contemporary literature review
    Kelly, J.
    Ladurner, A.
    Rickman, M.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (10): : 2267 - 2277
  • [27] Single column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis
    Khajavi, Kiarash
    Lee, Arthur T.
    Lindsey, Derek P.
    Leucht, Philipp
    Bellino, Michael J.
    Giori, Nicholas J.
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2010, 5
  • [28] Krappinger D, 2019, OPER ORTHOP TRAUMATO, V31, P503, DOI 10.1007/s00064-019-00631-0
  • [29] Pararectus approach vs. Stoppa approach for the treatment of acetabular fractures-a comparison of approach-related complications and operative outcome parameters from the German Pelvic Registry
    Kueper, Markus A.
    Roehm, Bjoern
    Audretsch, Christof
    Stoeckle, Ulrich
    Hoech, Andreas
    Histing, Tina
    Stuby, Fabian M.
    Trulson, Alexander
    Herath, Steven C.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (04)
  • [30] Letournel E., 1993, Fractures of the Acetabulum, V2nd, DOI [10.1007/978-3-642-75435-7, DOI 10.1007/978-3-642-75435-7]