The infraacetabular screw versus the antegrade posterior column screw in acetabulum fractures with posterior column involvement: a biomechanical comparison

被引:2
作者
Hinz, Nico [1 ,2 ]
Baumeister, Dirk [3 ]
Dehoust, Julius [2 ]
Muench, Matthias [4 ]
Frosch, Karl-Heinz [1 ,2 ]
Augat, Peter [3 ]
Hartel, Maximilian J. [1 ,2 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Trauma & Orthopaed Surg, Martinistr 52, D-20246 Hamburg, Germany
[2] BG Klinikum Hamburg, Dept Trauma Surg Orthopaed & Sports Traumatol, Bergedorfer Str 10, D-21033 Hamburg, Germany
[3] BG Unfallklin Murnau, Inst Biomech, Prof Kuentscher Str 8, D-82418 Murnau Am Staffelsee, Germany
[4] BG Klinikum Hamburg, Lab Biomech, Bergedorfer Str 10, D-21033 Hamburg, Germany
关键词
Acetabulum fracture; Anterior column plus posterior hemitransverse fracture; Antegrade posterior column screw; Infraacetabular screw; Suprapectineal plate; Biomechanical testing; HIP FRACTURE; FIXATION STRENGTH; ANTERIOR COLUMN; SURGERY; OLDER; POPULATION; AMBULATION; PLACEMENT; OUTCOMES;
D O I
10.1007/s00402-024-05324-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Traditionally, plate osteosynthesis of the anterior column combined with an antegrade posterior column screw is used for fixation of anterior column plus posterior hemitransverse (ACPHT) acetabulum fractures. Replacing the posterior column screw with an infraacetabular screw could improve the straightforwardness of acetabulum surgery, as it can be inserted using less invasive approaches, such as the AIP/Stoppa approach, which is a well-established standard approach. However, the biomechanical stability of a plate osteosynthesis combined with an infraacetabular screw instead of an antegrade posterior column screw is unknown. Material and methods Two osteosynthesis constructs were compared in a synthetic hemipelvis model with an ACPHT fracture: Suprapectineal plate + antegrade posterior column screw (APCS group) vs. suprapectineal plate + infraacetabular screw (IAS group). A single-leg stance test protocol with an additional passive muscle force and a cyclic loading of 32,000 cycles with a maximum effective load of 2400 N was applied. Interfragmentary motion and rotation of the three main fracture lines were measured. Results At the posterior hemitransverse fracture line, interfragmentary motion perpendicular to the fracture line (p < 0.001) and shear motion (p < 0.001) and at the high anterior column fracture line, interfragmentary motion longitudinal to the fracture line (p = 0.017) were significantly higher in the IAS group than in the APCS group. On the other hand, interfragmentary motion perpendicular (p = 0.004), longitudinal (p < 0.001) and horizontal to the fracture line (p = 0.004) and shear motion (p < 0.001) were significantly increased at the low anterior column fracture line in the APCS group compared to the IAS group. Conclusions Replacing the antegrade posterior column screw with an infraacetabular screw is not recommendable as it results in an increased interfragmentary motion, especially at the posterior hemitransverse component of an ACPHT fracture.
引用
收藏
页码:2573 / 2582
页数:10
相关论文
共 53 条
  • [1] Shear movement at the fracture site delays healing in a diaphyseal fracture model
    Augat, P
    Burger, J
    Schorlemmer, S
    Henke, T
    Peraus, M
    Claes, L
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (06) : 1011 - 1017
  • [2] The role of mechanical stimulation in the enhancement of bone healing *
    Augat, Peter
    Hollensteiner, Marianne
    von Rueden, Christian
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 : S78 - S83
  • [3] Surgical exposures and options for instrumentation in acetabular fracture fixation: Pararectus approach versus the modified Stoppa
    Bastian, J. D.
    Savic, M.
    Cullmann, J. L.
    Zech, W. D.
    Djonov, V.
    Keel, M. J.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (03): : 695 - 701
  • [4] A guideline for placement of an infra-acetabular screw based on anatomic landmarks via an intra-pelvic approach
    Baumann, Florian
    Schmitz, Paul
    Mahr, Daniel
    Kerschbaum, Maximilian
    Gaensslen, Axel
    Nerlich, Michael
    Worlicek, Michael
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [5] Comparison of two reinforcement rings for primary total hip arthroplasty addressing displaced acetabular fractures: a biomechanical analysis
    Becker, Johannes
    Winkler, M.
    von Rueden, C.
    Bliven, E.
    Augat, P.
    Resch, H.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (12) : 1947 - 1954
  • [6] HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS
    BERGMANN, G
    GRAICHEN, F
    ROHLMANN, A
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (08) : 969 - 990
  • [7] Hip contact forces and gait patterns from routine activities
    Bergmann, G
    Deuretzbacher, G
    Heller, M
    Graichen, F
    Rohlmann, A
    Strauss, J
    Duda, GN
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (07) : 859 - 871
  • [8] Osseous fixation pathways in pelvic and acetabular fracture surgery: Osteology, radiology, and clinical applications
    Bishop, Julius A.
    Routt, Milton Lee , Jr.
    [J]. JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 72 (06) : 1502 - 1509
  • [9] COLE JD, 1994, CLIN ORTHOP RELAT R, P112
  • [10] Infra-Acetabular Corridor-Technical Tip for an Additional Screw Placement to Increase the Fixation Strength of Acetabular Fractures
    Culemann, Ulf
    Marintschev, Ivan
    Gras, Florian
    Pohlemann, Tim
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (01): : 244 - 246