Enhancement of the Power-to-Heat Energy Conversion Process of a Thermal Energy Storage Cycle through the use of a Thermoelectric Heat Pump

被引:5
作者
Erro, I. [1 ]
Aranguren, P. [1 ]
Sorbet, F. J. [2 ]
Bonilla-Campos, I. [3 ]
Astrain, D. [1 ]
机构
[1] Univ Publ Navarra, Inst Smart Cities, Pamplona, Spain
[2] CENER Natl Renewable Energy Ctr Spain, Solar Energy Technol & Storage Dept, Sarriguren, Spain
[3] AIN Asociac Ind Navarra, Cordovilla, Navarra, Spain
关键词
COP; Energy Management; Power-to-Heat; Thermal Energy Storage; Thermoelectric Heat Pump; HIGH-TEMPERATURE HEAT; OPTIMIZATION;
D O I
10.1016/j.applthermaleng.2024.122923
中图分类号
O414.1 [热力学];
学科分类号
摘要
The principal strategy for achieving a neutral climate entails enhancing the share of renewable energies in the energy mix, in conjunction with promoting innovation in efficient technologies. Thermal energy storage systems have the potential to efficiently handle the intermittent nature of renewable energy sources. Furthermore, these systems can effectively handle shifts in both heat and electrical demand. Thus, efficient power -to -heat technologies are needed to boost thermal energy storage. This manuscript explores the potential of utilising a thermoelectric heat pump system in conjunction with electric resistances for charging a thermal energy storage. In order to achieve elevated temperatures, the thermoelectric system integrates thermoelectric heat pump blocks in a two -stage configuration. Air has been employed as a heat transfer medium for sensible heat storage. Higher airflow rates improve the performance of thermoelectric heat pump system. Moreover, its impact on the optimal voltage supply of the thermoelectric system is observed when it is combined with an electric resistance to achieve elevated temperatures. In comparison to the basic charging process that solely relies on the electric resistance of a thermal energy storage at 120 degrees C, a significant 30 % increase in power -to -heat energy conversion has been achieved by including the thermoelectric heat pump system. In fact, it efficiently elevates the temperature from the initial ambient temperature of 25 degrees C to a remarkable 113.1 degrees C, achieving a coefficient of performance of 1.35 with an airflow rate of 23 m 3 /h. Therefore, the use of this technology to enhance a complete process of storing excess renewable energy in the form of heat for subsequent use in both heat and electricity through a combined heat and power cycle is demonstrated.
引用
收藏
页数:12
相关论文
共 51 条
[1]   Enabling Technologies for Sector Coupling: A Review on the Role of Heat Pumps and Thermal Energy Storage [J].
Abdur Rehman, Omais ;
Palomba, Valeria ;
Frazzica, Andrea ;
Cabeza, Luisa F. .
ENERGIES, 2021, 14 (24)
[2]   Parametric study of phase change time reduction in a shell-and-tube ice storage system with anchor-type fin design [J].
Afsharpanah, Farhad ;
Ajarostaghi, Seyed Soheil Mousavi ;
Arici, Muslum .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 137
[3]   Thermophysical and chemical characterization of induction furnace slags for high temperature thermal energy storage in solar tower plants [J].
Agalit, H. ;
Zari, N. ;
Maaroufi, M. .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2017, 172 :168-176
[4]   Advances in thermal energy storage: Fundamentals and applications [J].
Ali, Hafiz Muhammad ;
Rehman, Tauseef-ur ;
Arici, Muesluem ;
Said, Zafar ;
Durakovic, Benjamin ;
Mohammed, Hayder I. ;
Kumar, Rajan ;
Rathod, Manish K. ;
Buyukdagli, Ozge ;
Teggar, Mohamed .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2024, 100
[5]  
[Anonymous], Technical data sheets: LR white embedding medium
[6]  
[Anonymous], Share of energy consumption from renewable sources in Europe
[7]  
[Anonymous], 17 GOALS SUSTAINABLE
[8]  
[Anonymous], Statistics | eurostat
[9]   Multiobjective optimization and analytical comparison of single- and 2-stage (series/parallel) thermoelectric heat pumps [J].
Arora, Ranjana ;
Arora, Rajesh .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2018, 42 (04) :1760-1778
[10]  
Arpagaus C., 2019, Experimental results of HFO/HCFO refrigerants in a laboratory scale HTHP with up to 150 C supply temperature