Comparison of noise-levels between superconducting gravimeter and gPhone gravimeter

被引:0
|
作者
Kun Zhang [1 ,2 ]
Ziwei Liu [1 ,2 ]
Xiaotong Zhang [1 ,2 ]
Ying Jiang [1 ,2 ]
机构
[1] Institute of Seismology China Earthquake Administration
[2] Key Laboratory of Earthquake Geodesy China Earthquake
关键词
D O I
暂无
中图分类号
P631.13 [];
学科分类号
摘要
For comparison of noise levels between superconducting gravimeters(SGs) and gPhone gravimeters, we conducted an experiment in which we carried out co-located observations of gravity changes by the same gPhone gravimeter and Superconducting Gravimeter(SG) at Wuhan, Lhasa and Lijiang stations respectively, and the observation at each station lasted approximately 2 months. We calculated the root mean square(RMS) of the gravity residual in each station and selected the five days in which the gravity residuals had the minimum RMS representing the background noise level as a quiet period. Based on the gravity residuals in these five quiet days, we calculated the mean power spectral density(PSD), seismic band noise magnitude(SNM) and sub-seismic band noise magnitude(SSNM). Furthermore, we simulated the influence of scale-factor error on SNM. We found that the SNM of the SGs ranged between 1.22 and 1.50 and the SSNM ranged from 3.96 to 4.74 during the experiment. The SNM of the gPhone gravimeter ranged from 2.93 to 3.06, and the SSNM of the gPhone gravimeter ranged between 4.17 and5.29. The SNM of the SG at Wuhan station was the highest among three SGs, while the corresponding SSNM was the lowest. The SG at Lhasa station, in contrast, had the highest SSNM and lowest SNM. The PSDs of gPhone gravimeters in high-frequency bands, including the seismic bands, were much larger than those of SGs. In the sub-seismic bands, SGs can approach or reach seismograph detection level. In the band frequency below 3×10-5 Hz, SGs and gPhone gravimeter have lower PSDs than seismometers,indicating that high-precision continuous gravimeters are better than seismometers in detecting longperiod signals. The variation of SNM caused by the scale-factor is generally in the range from -0.092 to 0.083, which has little influence on SNM result.
引用
收藏
页码:498 / 503
页数:6
相关论文
共 50 条
  • [11] Calibration of a superconducting gravimeter by comparison with an absolute gravimeter FG5 in Boulder
    Francis, O
    Niebauer, TM
    Sasagawa, G
    Klopping, F
    Gschwind, J
    GEOPHYSICAL RESEARCH LETTERS, 1998, 25 (07) : 1075 - 1078
  • [12] OSG-057 Superconducting Gravimeter Noise Levels in Lhasa (China)
    Zhang, Miaomiao
    Xu, Jianqiao
    Sun, Heping
    Chen, Xiaodong
    Zhou, Jiangcun
    TERRESTRIAL ATMOSPHERIC AND OCEANIC SCIENCES, 2016, 27 (06): : 807 - 817
  • [13] Tides, earthquakes and ground noise as seen by the absolute gravimeter FG5 and its superspring; comparison with a superconducting gravimeter and a broadband seismometer
    Hinderer, J
    Amalvict, M
    Crossley, D
    Leveque, JJ
    Rivera, L
    Luck, B
    METROLOGIA, 2002, 39 (05) : 495 - 501
  • [14] Calibration of the superconducting gravimeter based on a cold atom absolute gravimeter at NIM
    王启宇
    冯金扬
    王少凯
    庄伟
    赵阳
    牟丽爽
    吴书清
    ChinesePhysicsB, 2018, 27 (12) : 254 - 259
  • [15] CONTINUOUS MEASUREMENTS WITH THE SUPERCONDUCTING GRAVIMETER
    GOODKIND, JM
    TECTONOPHYSICS, 1979, 52 (1-4) : 99 - 105
  • [16] A 2-YEAR COMPARISON BETWEEN THE FRENCH AND CANADIAN SUPERCONDUCTING GRAVIMETER DATA
    HINDERER, J
    CROSSLEY, D
    XU, H
    GEOPHYSICAL JOURNAL INTERNATIONAL, 1994, 116 (02) : 252 - 266
  • [17] PRELIMINARY MEASUREMENTS WITH A SUPERCONDUCTING GRAVIMETER
    PROTHERO, WA
    GOODKIND, JM
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1968, 49 (04): : 663 - &
  • [18] Precision evaluation of calibration factor of a superconducting gravimeter using an absolute gravimeter
    Feng Jin-yang
    Wu Shu-qing
    Li Chun-jian
    Su Duo-wu
    Xu Jin-yi
    Yu Mei
    SEVENTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2016, 9903
  • [19] Calibration of the superconducting gravimeter based on a cold atom absolute gravimeter at NIM
    Wang, Qiyu
    Feng, Jinyang
    Wang, Shaokai
    Zhuang, Wei
    Zhao, Yang
    Mou, Lishuang
    Wu, Shuqing
    CHINESE PHYSICS B, 2018, 27 (12)
  • [20] Comparison of the Micro-g LaCoste gPhone-054 spring gravimeter and the GWR-C026 superconducting gravimeter in Strasbourg (France) using a 300-day time series
    Riccardi, U.
    Rosat, S.
    Hinderer, J.
    METROLOGIA, 2011, 48 (01) : 28 - 39