Validation of methods for effective orifice area measurement of prosthetic valves by two-dimensional and Doppler echocardiography following transcatheter self-expanding aortic valve implantation

被引:0
作者
Ming-Hu XIAO [1 ]
Yong-Jian WU [2 ]
Jing-Jin WANG [1 ]
Guang-Yuan SONG [2 ]
Jian-De WANG [1 ]
Zhen-Hui ZHU [1 ]
Xu WANG [3 ]
Zhen-Yan ZHAO [2 ]
Hao WANG [1 ]
机构
[1] Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College
[2] Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College
[3] Department of Surgery, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College
关键词
D O I
暂无
中图分类号
R654.2 [心脏];
学科分类号
1002 ; 100210 ;
摘要
Background The effective orifice area(EOA) is utilized to characterize the hemodynamic performance of the transcatheter heart valve(THV). However, there is no consensus on EOA measurement of self-expanding THV. We aimed to compare two echocardiographic methods for EOA measurement following transcatheter self-expanding aortic valve implantation. Methods EOA was calculated according to the continuity equation. Two methods were constructed. In Method 1 and Method 2, the left ventricular outflow tract diameter(LVOTd) was measured at the entry of the prosthesis(from trailing-to-leading edge) and proximal to the prosthetic valve leaflets(from trailing-toleading edge), respectively. The velocity-time integral(VTI) of the LVOT(VTILVOT) was recorded by pulsed-wave Doppler(PW) from apical windows. The region of the PW sampling should match that of the LVOTd measurement with precise localization. The mean transvalvular pressure gradient(MG) and VTI of THV was measured by Continuous wave Doppler. Results A total of 113 consecutive patients were recruited. The mean age was 77.2 ± 5.5 years, and 72 patients(63.7%) were male. EOA1with the use of Method 1 was larger than EOA2(1.56 ± 0.39 cm2 vs. 1.48 ± 0.41 cm2, P = 0.001). MG correlated better with the indexed EOA1(EOAI1)(r =-0.701, P < 0.001) than EOAI2(r =-0.645, P < 0.001). According to EOAI(EOAI ≤ 0.65 cm2/m2, respectively), the proportion of sever prosthesis-patient mismatch with the use of EOA1was lower than EOA2(12.4% vs. 21.2%, P < 0.05). Compared with EOA2, EOA1had lower interobserver and intra-observer variability(intra: 0.5% ± 17% vs. 3.8% ± 22%, P < 0.001; inter: 1.0% ± 9% vs. 3.5% ± 11%, P < 0.001). Conclusions For transcatheter self-expanding valve EOA measurement, LVOTd should be measured in the entry of the prosthesis stent(from trailing-to-leading edge), and VTILVOT should match that of the LVOTd measurement with precise localization.
引用
收藏
页码:766 / 774
页数:9
相关论文
共 50 条
  • [21] Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation
    Mohammad A. Sherif
    Hüseyin Ince
    Octavian Maniuc
    Therese Reiter
    Wolfram Voelker
    Georg Ertl
    Alper Öner
    [J]. BMC Cardiovascular Disorders, 15
  • [22] Meta-analysis Comparing Valve-In-Valve Transcatheter Aortic Valve Implantation With Self-Expanding Versus Balloon-Expandable Valves
    Hamilton, Garry W.
    Koshy, Anoop N.
    Fulcher, Jordan
    Tang, Gilbert H. L.
    Bapat, Vinayak
    Murphy, Alexandra
    Horrigan, Mark
    Farouque, Omar
    Yudi, Matias B.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2020, 125 (10) : 1558 - 1565
  • [23] Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation
    Sherif, Mohammad A.
    Ince, Hueseyin
    Maniuc, Octavian
    Reiter, Therese
    Voelker, Wolfram
    Ertl, Georg
    Oener, Alper
    [J]. BMC CARDIOVASCULAR DISORDERS, 2015, 15
  • [24] Comparison of Transvalvular Aortic Mean Gradients Obtained by Intraprocedural Echocardiography and Invasive Measurement in Balloon and Self-Expanding Transcatheter Valves
    Abbas, Amr E.
    Mando, Ramy
    Kadri, Amer
    Khalili, Houman
    Hanzel, George
    Shannon, Francis
    Al-Azizi, Karim
    Waggoner, Thomas
    Kassas, Safwan
    Pilgrim, Thomas
    Okuno, Taishi
    Camacho, Alexander
    Selberg, Alexandra
    Elmariah, Sammy
    Bavry, Anthony
    Ternacle, Julien
    Christensen, Jared
    Gheewala, Neil
    Pibarot, Philippe
    Mack, Michael
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (19):
  • [25] Resheathing of self-expanding bioprosthesis: Impact on procedural results, clinical outcome and prosthetic valve durability after transcatheter aortic valve implantation
    Kefer, Joelle
    Maes, Frederic
    Renkin, Jean
    Kautbally, Shakeel
    De Meester, Christophe
    Delacour, Marine
    Pouleur, Anne-Catherine
    [J]. IJC HEART & VASCULATURE, 2020, 26
  • [26] Comparison of Local Versus General Anesthesia Following Transfemoral Transcatheter Self-Expanding Aortic Valve Implantation (from the Transcatheter Valve Therapeutics Registry)
    Attizzani, Guilherme F.
    Patel, Sandeep M.
    Dangas, George D.
    Szeto, Wilson Y.
    Sorajja, Paul
    Reardon, Michael J.
    Popma, Jeffrey J.
    Kodali, Susheel
    Chenoweth, Sharla
    Costa, Marco A.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2019, 123 (03) : 419 - 425
  • [27] Optimal positioning of self-expanding valves before deployment decreases paravalvular regurgitation following transcatheter aortic valve replacement
    Dadu, Razvan T.
    Xu, Jiaqiong
    Rehman, Hasan
    von Ballmoos, Moritz Wyler
    Barker, Colin M.
    Reyes, Manuel
    Ramchandani, Mahesh
    Reul, Ross M.
    Reardon, Michael J.
    Kleiman, Neal S.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (01) : 149 - 155
  • [28] Multicenter comparison of transcatheter aortic valve implantation with the self-expanding ACURATE neo2 versus Evolut PRO transcatheter heart valves
    Tobias Rheude
    Costanza Pellegrini
    Martin Landt
    Sabine Bleiziffer
    Alexander Wolf
    Matthias Renker
    Jonas Neuser
    Oliver Dörr
    Abdelhakim Allali
    Tanja K. Rudolph
    Jan Martin Wambach
    Julian D. Widder
    Parminder Singh
    Dominik Berliner
    Hector A. Alvarez-Covarrubias
    Gert Richardt
    Erion Xhepa
    Won-Keun Kim
    Michael Joner
    [J]. Clinical Research in Cardiology, 2024, 113 : 38 - 47
  • [29] Multicenter comparison of transcatheter aortic valve implantation with the self-expanding ACURATE neo2 versus Evolut PRO transcatheter heart valves
    Rheude, Tobias
    Pellegrini, Costanza
    Landt, Martin
    Bleiziffer, Sabine
    Wolf, Alexander
    Renker, Matthias
    Neuser, Jonas
    Doerr, Oliver
    Allali, Abdelhakim
    Rudolph, Tanja K. K.
    Wambach, Jan Martin
    Widder, Julian D. D.
    Singh, Parminder
    Berliner, Dominik
    Alvarez-Covarrubias, Hector A. A.
    Richardt, Gert
    Xhepa, Erion
    Kim, Won-Keun
    Joner, Michael
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2024, 113 (01) : 38 - 47
  • [30] Early Echocardiographic Assessment Following Transcatheter Aortic Valve Implantation with the CoreValve ReValving System Self-Expanding Aortic Vale Prosthesis
    Piazza, Nicolo
    Galema, Tjebbe
    Otten, Amber
    Soliman, Osama I. I.
    van Dalen, Bas M.
    Geleijnse, Marcel
    Kappetein, Arie Pieter
    Garcia, Hector Garcia
    van Es, Gerrit-Anne
    Serruys, Patrick W.
    de Jaegere, Peter
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A) : 234I - 234I