Validation of methods for effective orifice area measurement of prosthetic valves by two-dimensional and Doppler echocardiography following transcatheter self-expanding aortic valve implantation

被引:0
|
作者
Ming-Hu XIAO [1 ]
Yong-Jian WU [2 ]
Jing-Jin WANG [1 ]
Guang-Yuan SONG [2 ]
Jian-De WANG [1 ]
Zhen-Hui ZHU [1 ]
Xu WANG [3 ]
Zhen-Yan ZHAO [2 ]
Hao WANG [1 ]
机构
[1] Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College
[2] Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College
[3] Department of Surgery, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College
关键词
D O I
暂无
中图分类号
R654.2 [心脏];
学科分类号
1002 ; 100210 ;
摘要
Background The effective orifice area(EOA) is utilized to characterize the hemodynamic performance of the transcatheter heart valve(THV). However, there is no consensus on EOA measurement of self-expanding THV. We aimed to compare two echocardiographic methods for EOA measurement following transcatheter self-expanding aortic valve implantation. Methods EOA was calculated according to the continuity equation. Two methods were constructed. In Method 1 and Method 2, the left ventricular outflow tract diameter(LVOTd) was measured at the entry of the prosthesis(from trailing-to-leading edge) and proximal to the prosthetic valve leaflets(from trailing-toleading edge), respectively. The velocity-time integral(VTI) of the LVOT(VTILVOT) was recorded by pulsed-wave Doppler(PW) from apical windows. The region of the PW sampling should match that of the LVOTd measurement with precise localization. The mean transvalvular pressure gradient(MG) and VTI of THV was measured by Continuous wave Doppler. Results A total of 113 consecutive patients were recruited. The mean age was 77.2 ± 5.5 years, and 72 patients(63.7%) were male. EOA1with the use of Method 1 was larger than EOA2(1.56 ± 0.39 cm2 vs. 1.48 ± 0.41 cm2, P = 0.001). MG correlated better with the indexed EOA1(EOAI1)(r =-0.701, P < 0.001) than EOAI2(r =-0.645, P < 0.001). According to EOAI(EOAI ≤ 0.65 cm2/m2, respectively), the proportion of sever prosthesis-patient mismatch with the use of EOA1was lower than EOA2(12.4% vs. 21.2%, P < 0.05). Compared with EOA2, EOA1had lower interobserver and intra-observer variability(intra: 0.5% ± 17% vs. 3.8% ± 22%, P < 0.001; inter: 1.0% ± 9% vs. 3.5% ± 11%, P < 0.001). Conclusions For transcatheter self-expanding valve EOA measurement, LVOTd should be measured in the entry of the prosthesis stent(from trailing-to-leading edge), and VTILVOT should match that of the LVOTd measurement with precise localization.
引用
收藏
页码:766 / 774
页数:9
相关论文
共 50 条
  • [1] Validation of methods for effective orifice area measurement of prosthetic valves by two-dimensional and Doppler echocardiography following transcatheter self-expanding aortic valve implantation
    Xiao, Ming-Hu
    Wu, Yong-Jian
    Wang, Jing-Jin
    Song, Guang-Yuan
    Wang, Jian-De
    Zhu, Zhen-Hui
    Wang, Xu
    Zhao, Zhen-Yan
    Wang, Hao
    JOURNAL OF GERIATRIC CARDIOLOGY, 2020, 17 (12) : 766 - 774
  • [2] Validation and Characterization of Transcatheter Aortic Valve Effective Orifice Area Measured by Doppler Echocardiography
    Clavel, Marie-Annick
    Rodes-Cabau, Josep
    Dumont, Eric
    Bagur, Rodrigo
    Bergeron, Sebastien
    De Larochelliere, Robert
    Doyle, Daniel
    Larose, Eric
    Dumesnil, Jean G.
    Pibarot, Philippe
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (10) : 1053 - 1062
  • [3] Validation and characterization of Doppler-echocardiographicmeasures of prosthetic valve effective area following transcatheter aortic implantation
    Clavel, M. -A.
    Rodes-Cabau, J.
    Bergeron, S.
    Dumont, E.
    Bagur, R.
    De larochelliere, R.
    Doyle, D.
    Lemieux, J.
    Dumesnil, J. G.
    Pibarot, P.
    EUROPEAN HEART JOURNAL, 2011, 32 : 891 - 891
  • [4] A Comparative Study of Transcatheter Aortic Valve Implantation Views for Two Different Self-Expanding Aortic Valves
    Bajoras, Vilhelmas
    Wong, Ivan
    Wang, Xi
    Cerlinskaite-Bajore, Kamile
    Bieliauskas, Gintautas
    De Backer, Ole
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2024, 8 (03):
  • [5] METHODS AND DETERMINANTS OF DOPPLER-ECHOCARDIOGRAPHIC MEASURES OF PROSTHETIC VALVE EFFECTIVE AREA FOLLOWING TRANSCATHETER AORTIC IMPLANTATION
    Clavel, M.
    Rodes-Cabau, J.
    Bergeron, S.
    Dumont, E.
    Bagur, R.
    De Larocheliere, R.
    Doyle, D.
    Lemieux, J.
    Dumesnil, J. G.
    Pibarot, P.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S230 - S230
  • [6] Method to Measure the Valve Effective Orifice Area Following Transcatheter Aortic Valve Implantation
    Clavel, Marie-Annick
    Rodes-Cabau, Josep
    Dumont, Eric
    Bergeron, Sebastien
    Bagur, Rodrigo
    De Larochelliere, Robert
    Doyle, Daniel
    Larose, Eric
    Pibarot, Philippe
    CIRCULATION, 2010, 122 (21)
  • [7] Assessment of effective orifice area of prosthetic aortic valves with Doppler echocardiography: An in vivo and in vitro study
    Bech-Hanssen, O
    Caidahl, K
    Wallentin, I
    Ask, P
    Wranne, B
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (02): : 287 - 295
  • [8] Predictors and neurological consequences of periprocedural cerebrovascular events following transcatheter aortic valve implantation with self-expanding valves
    Suhai, Ferenc Imre
    Varga, Andrea
    Szilveszter, Balint
    Nagy-Vecsey, Milan
    Apor, Astrid
    Nagy, Aniko Ilona
    Kolossvary, Marton
    Karady, Julia
    Bartykowszki, Andrea
    Molnar, Levente
    Jermendy, Adam L.
    Panajotu, Alexisz
    Maurovich-Horvat, Pal
    Merkely, Bela
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [9] Outcomes and Hemodynamic Performances of Transcatheter Aortic Valve Replacement with Two Generations of Self-Expanding Transcatheter Aortic Valves
    Kuo, Chia-Cheng
    Chang, Hsiao-Huang
    Leu, Hsin-Bang
    Chen, I-Ming
    Chen, Po-Lin
    Lin, Su-Man
    Chen, Ying-Hwa
    ACTA CARDIOLOGICA SINICA, 2023, 39 (03) : 449 - 456
  • [10] Prosthesis position and its influence on complications after transcatheter aortic valve implantation with self-expanding valves
    Breitbart, P.
    Minners, J.
    Hein, M.
    Schroefel, H.
    Neumann, F. J.
    Ruile, P.
    EUROPEAN HEART JOURNAL, 2021, 42 : 176 - 176