Transient Heat Transfer Study of Direct Contact Condensation of Steam in Spray Cooling Water

被引:0
|
作者
Yiping Wang [1 ,2 ]
Yunfa Hu [1 ]
Qunwu Huang [1 ]
Yong Cui [3 ]
机构
[1] School of Chemical Engineering and Technology,Tianjin University
[2] School of Architecture,Tianjin University
[3] Tianjin University Research Institute of Architectural
关键词
D O I
暂无
中图分类号
TK124 [传热学];
学科分类号
摘要
We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 1045 mm. We applied a new analysis method for the steam state equation to analyze the molar quantity change in steam over the course of the experiment and determined the transient steam variation. We also investigated the influence of flow rates and temperatures ofcooling water on the efficiency ofsteam condensation. Our experimental results show that appropriate increasing of the cooling water flow rate can significantly accelerate the steam condensation. We achieved a rapid increase in the total volumetric heat transfer coefficient by increasing the flow rate of cooling water, which indicated a higher thermal convection between the steam and the cooling water with higher flow rates. We found that the temperature ofcooling water did not play an important role on steam condensation. This method was confirmed to be effective for rapid recovering ofsteam.
引用
收藏
页码:131 / 143
页数:13
相关论文
共 50 条
  • [1] Transient Heat Transfer Study of Direct Contact Condensation of Steam in Spray Cooling Water
    Wang Y.
    Hu Y.
    Huang Q.
    Cui Y.
    Transactions of Tianjin University, 2018, 24 (2) : 131 - 143
  • [2] Transient Heat Transfer Study of Direct Contact Condensation of Steam in Spray Cooling Water
    Yiping Wang
    Yunfa Hu
    Qunwu Huang
    Yong Cui
    Transactions of Tianjin University, 2018, 24 (02) : 131 - 143
  • [3] Heat transfer in direct contact condensation of steam to subcooled water spray
    Takahashi, M
    Nayak, AK
    Kitagawa, S
    Murakoso, H
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2001, 123 (04): : 703 - 710
  • [4] Numerical investigation of heat transfer in direct contact condensation of steam to subcooled water spray
    Ding, Hengtao
    Luo, Yiqing
    Yuan, Xigang
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2019, 140 : 52 - 63
  • [5] PREDICTION OF HEAT-TRANSFER BY DIRECT CONTACT CONDENSATION AT A STEAM SUBCOOLED WATER INTERFACE
    MURATA, A
    HIHARA, E
    SAITO, T
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (01) : 101 - 109
  • [6] STEAM BUBBLING REGIMES AND DIRECT CONTACT CONDENSATION HEAT-TRANSFER IN HIGHLY SUBCOOLED WATER
    JEJE, A
    ASANTE, B
    ROSS, B
    CHEMICAL ENGINEERING SCIENCE, 1990, 45 (03) : 639 - 650
  • [7] EVALUATION OF HEAT-TRANSFER COEFFICIENT AT DIRECT-CONTACT CONDENSATION OF COLD WATER AND STEAM
    AYA, I
    NARIAI, H
    NUCLEAR ENGINEERING AND DESIGN, 1991, 131 (01) : 17 - 24
  • [8] Direct-contact condensation heat transfer on downcommerless trays for steam-water system
    Genic, SB
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (7-8) : 1225 - 1230
  • [9] Transient analysis of the steam-water direct contact condensation in the packed column
    Hu, Yunfa
    Wang, Yiping
    Huang, Qunwu
    Cui, Yong
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2018, 96 (01): : 404 - 413
  • [10] Experimental Study of Direct Contact Condensation of Steam on Water Droplets
    Gumruk, Semra
    Aktas, Murat K.
    WORLD CONGRESS ON ENGINEERING, WCE 2015, VOL II, 2015, : 1071 - 1075