Pollution levels and characteristics of phthalate esters in indoor air in hospitals

被引:7
|
作者
Xueqing Wang [1 ]
Min Song [1 ,2 ]
Min Guo [1 ,3 ]
Chenchen Chi [1 ]
Feifei Mo [1 ]
Xueyou Shen [1 ,4 ]
机构
[1] College of Environmental & Resource Sciences, Zhejiang University
[2] Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences
[3] Chinese Research Academy of Environmental Sciences
[4] Zhejiang Provincial Key Laboratory of Organic Pollution and Control
基金
国家高技术研究发展计划(863计划); 美国国家科学基金会;
关键词
Air pollution Hospital Indoor air Phthalate concentrations;
D O I
暂无
中图分类号
X51 [大气污染及其防治]; TU834.8 [空气净化];
学科分类号
0706 ; 070602 ;
摘要
The concentrations of phthalate esters(PAEs) in Chinese hospitals were investigated by simultaneously determining concentrations of gas- and particle-phase PAEs. PAEs were detected in two third-class first-grade hospitals, two second-class first-grade hospitals, and a community health service center. Hospital drugstores had the highest concentration(24.19 μg/m3), which was 1.54 times that of newly decorated houses. The second highest concentration was found in the transfusion rooms, averaging 21.89 μg/m3; this was followed by the concentrations of PAEs in the nurse’s workstations, the wards, and the doctor’s offices, with mean concentrations of 20.66, 20.0, and 16.92 μg/m3, respectively. The lowest concentrations were found in the hallways(16.30 μg/m3). Of the six different kinds of PAEs found, major pollutants included diethyl phthalates, dibutyl phthalates, butylbenzyl phthalates and di(2-ethylhexyl) phthalates, comprising more than 80% of all PAEs present.Meanwhile, a comparison between different wards showed that PAE concentrations in the maternity wards were 1.63 times higher than in the main wards. Based on known health hazards, our results suggest that the PAEs seriously influence the health of the pregnant women and babies; therefore, it is of great importance to take the phthalate concentrations in hospitals into consideration. In addition, hospital indoor air was more seriously contaminated than the air of newly decorated houses.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 50 条
  • [1] Pollution levels and characteristics of phthalate esters in indoor air in hospitals
    Wang, Xueqing
    Song, Min
    Guo, Min
    Chi, Chenchen
    Mo, Feifei
    Shen, Xueyou
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2015, 37 : 67 - 74
  • [2] Pollution levels and characteristics of phthalate esters in indoor air of offices
    Min Song
    Chenchen Chi
    Min Guo
    Xueqing Wang
    Lingxiao Cheng
    Xueyou Shen
    Journal of Environmental Sciences, 2015, 28 (02) : 157 - 162
  • [3] Pollution levels and characteristics of phthalate esters in indoor air of offices
    Song, Min
    Chi, Chenchen
    Guo, Min
    Wang, Xueqing
    Cheng, Lingxiao
    Shen, Xueyou
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2015, 28 : 157 - 162
  • [4] Human exposure to phthalate esters from indoor air and dust in China
    Lin, Xingtao
    Wang, Xiaoyi
    Shen, Ting
    MANUFACTURE ENGINEERING AND ENVIRONMENT ENGINEERING, VOLS 1 AND 2, 2014, 84 : 1139 - 1144
  • [5] The characteristics of indoor air pollution in different rooms
    Tian, LW
    Zhang, GQ
    Liu, JL
    Zheng, C
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 203 - 207
  • [6] Emissions of two phthalate esters and BDE 209 to indoor air and their impact on urban air quality
    Cousins, Anna Palm
    Holmgren, Tomas
    Remberger, Mikael
    SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 470 : 527 - 535
  • [7] Phthalate levels in Norwegian indoor air related to particle size fraction
    Rakkestad, Kirsten Eline
    Dye, Christian Jarle
    Yttri, Karl Espen
    Holme, Jorn Andreas
    Hongslo, Jan Kenneth
    Schwarze, Per Everhard
    Becher, Rune
    JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (12): : 1419 - 1425
  • [8] Simultaneous determination of phosphate esters and phthalate esters in clean room air and indoor air by gas chromatography-mass spectrometry
    Toda, H
    Sako, K
    Yagome, Y
    Nakamura, T
    ANALYTICA CHIMICA ACTA, 2004, 519 (02) : 213 - 218
  • [9] Source apportionment and pollution of BTEX in indoor and outdoor air of Guangzhou hospitals
    College of Resource and Environment, South China Agricultural University, Guangzhou 510642, China
    不详
    Zhongguo Huanjing Kexue, 2008, 12 (1127-1132):
  • [10] Organophosphate and phthalate esters in air and settled dust - a multi-location indoor study
    Bergh, C.
    Torgrip, R.
    Emenius, G.
    Ostman, C.
    INDOOR AIR, 2011, 21 (01) : 67 - 76