A MONTE-CARLO INVESTIGATION OF THE DOSIMETRIC PROPERTIES OF MONOENERGETIC NEUTRON BEAMS FOR NEUTRON-CAPTURE THERAPY

被引:50
作者
YANCH, JC [1 ]
ZHOU, XL [1 ]
BROWNELL, GL [1 ]
机构
[1] MIT,WHITAKER COLL HLTH SCI & TECHNOL,CAMBRIDGE,MA 02139
关键词
D O I
10.2307/3578165
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A Monte Carlo simulation study has been carried out to investigate the suitability of neutron beams of various energies for therapeutic efficacy in boron neutron capture therapy. The dosimetric properties of unidirectional, monoenergetic neutron beams of varying diameters in two different phantoms (a right-circular cylinder and an ellipsoid) made of brain-equivalent material were examined. The source diameter was varied from 0.0 to 20.0 cm; neutron energies ranged from 0.025 eV up to 800 keV, the maximum neutron energy generated by a tandem cascade accelerator using 2.5-MeV protons in a 7Li(p,n)7Be reaction. Such a device is currently under investigation for use as a neutron source for boron neutron capture therapy. The simulation studies indicate that the maximum effective treatment depth (advantage depth) in the brain is 10.0 cm and is obtainable with a 10-keV neutron beam. A useful range of energies, defined as those of neutron energies capable of effectively treating to a depth of 7 cm in brain tissue, is found to be 4.0 eV to 40.0 keV. Beam size is shown not to affect advantage depth as long as the entire phantom volume is used in determining this depth. Dose distribution in directions parallel to and perpendicular to the beam direction are shown to illustrate this phenomenon graphically as well as to illustrate the differences in advantage depth and advantage ratio and the contribution of individual dose components to tumor dose caused by the geometric differences in phantom shape.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 22 条
[1]  
BARTH RF, 1990, CANCER RES, V50, P1061
[2]  
Belanova T.S., 1986, NEUTRON RAD CAPTURE
[3]  
Briesmeister, 1986, MCNP GEN MONTE CARLO
[4]   EXPLANATION OF CEREBRAL WHITE-GRAY CONTRAST IN COMPUTED-TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G ;
KELLER, MR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (04) :489-491
[5]  
BROWNELL GL, 1986, NEUTRON CAPTURE THER
[6]  
BROWNELL GL, 1959, PROGR NUCLEAR ENERGY, V2, P114
[7]  
BROWNELL GL, 1978, THERAPY NUCLEAR MED
[8]  
CASWELL RS, 1982, INT J APPL RADIAT IS, V33, P1227, DOI 10.1016/0020-708X(82)90246-0
[9]  
CLEMENT SD, 1990, NEUTRON BEAM DESIGN
[10]  
DEUTSCH OL, 1975, NUCLEAR TECH, V25, P320