MEASURING CLINICAL ATTACHMENT - REPRODUCIBILITY OF RELATIVE MEASUREMENTS WITH AN ELECTRONIC PROBE

被引:31
作者
CLARK, WB
YANG, MCK
MAGNUSSON, I
机构
[1] UNIV FLORIDA,DEPT ORAL BIOL,GAINESVILLE,FL 32611
[2] UNIV FLORIDA,DEPT STAT,GAINESVILLE,FL 32611
关键词
PERIODONTITIS DIAGNOSIS; GINGIVITIS DIAGNOSIS; PERIODONTAL ATTACHMENT; ELECTRONIC PROBE; RADIOGRAPHY; SUBTRACTION INSTRUMENTATION;
D O I
10.1902/jop.1992.63.10.831
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
DURING THE PAST FEW YEARS, improvements in detecting longitudinal changes in clinical attachment or alveolar bone density have been introduced. For example, constant-force electronic probes and computer-assisted subtraction analysis of longitudinal radiographs have been reported to be more sensitive and reproducible in detecting changes in clinical attachment or alveolar bone density, respectively. Use of these new technologies requires that sources of measurement error be identified and their contribution quantified. This study investigated the reproducibility of a constant-force electronic probe in a careful clinical setting. Measurements were performed from individually fabricated acrylic stents. Three groups of subjects were selected for the study: 10 adults without oral disease, 10 adults with gingivitis, and 10 adults with moderate periodontitis. Four probing designs were employed to investigate the reproducibility of the probe. In design A, the probe tip was left in the sulcus between successive probings. In design B, the probe tip was removed from the gingival margin between probings but the next probing followed immediately. In design C, successive whole-mouth probings were interrupted by a 5-minute interval and a mouth rinse. In design D there was a 4-week interval between each successive probing. Three measurements were taken at each site for each design. The main purpose of this study was to identify variance components in the attachment level variation. The maximum probing error standard deviation ranged from 0.2 to 0.3 mm depending on the periodontal health of the subject. This level of variation is considerably smaller than that found in most previous studies. Reduction of measurement errors may lead to an increase in measurement sensitivity, possibly resulting in detection of smaller changes in attachment in a shorter time interval.
引用
收藏
页码:831 / 838
页数:8
相关论文
共 32 条
  • [1] EFFECT OF TRAINING AND PROBING FORCE ON THE REPRODUCIBILITY OF POCKET DEPTH MEASUREMENTS
    ABBAS, F
    HART, AAM
    OOSTING, J
    VANDERVELDEN, U
    [J]. JOURNAL OF PERIODONTAL RESEARCH, 1982, 17 (02) : 226 - 234
  • [2] REPRODUCIBILITY OF PROBING ATTACHMENT LEVEL MEASUREMENTS
    BADERSTEN, A
    NILVEUS, R
    EGELBERG, J
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1984, 11 (07) : 475 - 485
  • [3] RELIABILITY OF ATTACHMENT LOSS MEASUREMENTS IN A LONGITUDINAL CLINICAL-TRIAL
    BEST, AM
    BURMEISTER, JA
    GUNSOLLEY, JC
    BROOKS, CN
    SCHENKEIN, HA
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1990, 17 (08) : 564 - 569
  • [4] GINGIVAL ATTACHMENT LEVEL MEASUREMENTS WITH AN AUTOMATED PERIODONTAL PROBE
    BIREK, P
    MCCULLOCH, CAG
    HARDY, V
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1987, 14 (08) : 472 - 477
  • [5] COMPUTER-ASSISTED DENSITOMETRIC IMAGE-ANALYSIS (CADIA) FOR THE ASSESSMENT OF ALVEOLAR BONE-DENSITY CHANGES IN FURCATIONS
    BRAGGER, U
    PASQUALI, L
    WEBER, H
    KORNMAN, KS
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1989, 16 (01) : 46 - 52
  • [6] THE RELATIONSHIP BETWEEN PROBING ATTACHMENT LOSS AND COMPUTERIZED RADIOGRAPHIC ANALYSIS IN MONITORING PROGRESSION OF PERIODONTITIS
    DEAS, DE
    PASQUALI, LA
    YUAN, CH
    KORNMAN, KS
    [J]. JOURNAL OF PERIODONTOLOGY, 1991, 62 (02) : 135 - 141
  • [7] WITHIN-MOUTH CORRELATIONS AND RELIABILITIES FOR PROBING DEPTH AND ATTACHMENT LEVEL
    FLEISS, JL
    PARK, MH
    CHILTON, NW
    [J]. JOURNAL OF PERIODONTOLOGY, 1987, 58 (07) : 460 - 463
  • [8] HISTOLOGIC PROBE POSITION IN TREATED AND UNTREATED HUMAN PERIODONTAL TISSUES
    FOWLER, C
    GARRETT, S
    CRIGGER, M
    EGELBERG, J
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1982, 9 (05) : 373 - 385
  • [9] GENCO RJ, 1990, CONT PERIODONTICS, P348
  • [10] DESCRIPTION AND CLINICAL-EVALUATION OF A NEW COMPUTERIZED PERIODONTAL PROBE - THE FLORIDA PROBE
    GIBBS, CH
    HIRSCHFELD, JW
    LEE, JG
    LOW, SB
    MAGNUSSON, I
    THOUSAND, RR
    YERNENI, P
    CLARK, WB
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (02) : 137 - 144