AN ECONOMICAL X-RAY AREA DETECTOR BASED ON AN INTENSIFIED CCD UNIT

被引:5
|
作者
GAO, T [1 ]
LI, YJ [1 ]
ROUSSEAU, J [1 ]
LINLIU, K [1 ]
CHU, B [1 ]
机构
[1] SUNY STONY BROOK,DEPT CHEM,STONY BROOK,NY 11794
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1993年 / 64卷 / 02期
关键词
D O I
10.1063/1.1144262
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An economical charge-coupled device (CCD) based area detector for x-ray experiments was developed and assembled. Although low in cost, careful evaluation shows that this detector consisting of an optical fiber taper, an image intensifier, a relay lens, and a cooled CCD unit has good overall features and is comparable with other reported CCD based x-ray area detectors. The detector is suitable for small-angle x-ray scattering and wide-angle x-ray diffraction experiments employing either synchrotron or conventional x-ray sources. It also has several options which we could utilize under different experimental conditions. The test result, its limitations, and possible improvements are discussed.
引用
收藏
页码:390 / 396
页数:7
相关论文
共 50 条
  • [1] X-ray imaging using CCD based area detector
    Sinha, A
    SOLID STATE PHYSICS, VOL 41, 1998, 1999, : 71 - 74
  • [2] ECONOMICAL X-RAY AREA DETECTOR FOR FOCUSING AND ALIGNMENT PURPOSES
    CHU, B
    ROUSSEAU, J
    GAO, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (08): : 4000 - 4002
  • [3] AN AREA X-RAY-DETECTOR SYSTEM BASED ON A COMMERCIALLY AVAILABLE CCD-UNIT
    FUCHS, HF
    QU, DQ
    CHU, B
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (02): : 712 - 716
  • [4] AN IMAGE-INTENSIFIED CCD AREA X-RAY-DETECTOR FOR USE WITH SYNCHROTRON RADIATION
    TEMPLER, RH
    GRUNER, SM
    EIKENBERRY, EF
    ADVANCES IN ELECTRONICS AND ELECTRON PHYSICS, 1988, 74 : 275 - 283
  • [5] Development of large area CCD-based X-ray detector for macromolecular crystallography
    Pokric, M
    Allinson, NM
    Jorden, AR
    Cox, MP
    Marshall, A
    Long, PG
    Moon, K
    Jerram, P
    Pool, P
    Nave, C
    Derbyshire, GE
    Helliwell, JR
    DETECTORS FOR CRYSTALLOGRAPHY AND DIFFRACTION STUDIES AT SYNCHROTRON SOURCES, 1999, 3774 : 46 - 57
  • [6] A large area CCD X-ray detector for exotic atom spectroscopy
    Nelms, N
    Anagnostopoulos, DF
    Ayranov, O
    Borchert, G
    Egger, JP
    Gotta, D
    Hennebach, M
    Indelicato, P
    Leoni, B
    Liu, YW
    Manil, B
    Simons, LM
    Wells, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 419 - 431
  • [7] AREA DETECTOR DESIGN .2. APPLICATION TO A MODULAR CCD-BASED DETECTOR FOR X-RAY CRYSTALLOGRAPHY
    STANTON, M
    PHILLIPS, WC
    OMARA, D
    NADAY, I
    WESTBROOK, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 325 (03): : 558 - 567
  • [8] CCD-based X-ray area detector for time-resolved diffraction experiments
    Yagi, N
    Inoue, K
    Oka, T
    JOURNAL OF SYNCHROTRON RADIATION, 2004, 11 : 456 - 461
  • [9] A CCD-BASED AREA DETECTOR FOR X-RAY CRYSTALLOGRAPHY USING SYNCHROTRON AND LABORATORY SOURCES
    PHILLIPS, WC
    LI, YL
    STANTON, M
    XIE, JH
    OMARA, D
    KALATA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 334 (2-3): : 621 - 630
  • [10] Soft X-ray spectrograph with CCD-Based detector
    Volkov, GS
    Zaitsev, VI
    AttelanLanglet, S
    Mishenskii, VO
    Papazyan, YV
    Fedulov, MV
    Smirnov, VP
    Etlicher, B
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1997, 40 (01) : 113 - 117